4D Flow MRI in Ascending Aortic Aneurysms: Reproducibility of Hemodynamic Parameters

被引:1
|
作者
Juffermans, Joe F. [1 ]
van Assen, Hans C. [1 ]
te Kiefte, Bastiaan J. C. [1 ]
Ramaekers, Mitch J. F. G. [1 ,2 ,3 ,4 ]
van der Palen, Roel L. F. [5 ]
van den Boogaard, Pieter [1 ]
Adriaans, Bouke P. [2 ,3 ,4 ]
Wildberger, Joachim E. [3 ,4 ]
Dekkers, Ilona A. [1 ]
Scholte, Arthur J. H. A. [6 ]
Schalla, Simon [2 ,3 ,4 ]
Lamb, Hildo J. [1 ]
Westenberg, Jos J. M. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, NL-2333 ZA Leiden, Netherlands
[2] Maastricht Univ, Med Ctr, Dept Cardiol, NL-6229 HX Maastricht, Netherlands
[3] Maastricht Univ, Med Ctr, Dept Radiol & Nucl Med, NL-6229 HX Maastricht, Netherlands
[4] Cardiovasc Res Inst Maastricht, NL-6229 HX Maastricht, Netherlands
[5] Leiden Univ, Med Ctr, Dept Pediat, Div Pediat Cardiol, NL-2333 ZA Leiden, Netherlands
[6] Leiden Univ, Med Ctr, Dept Cardiol, NL-2333 ZA Leiden, Netherlands
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 08期
关键词
aorta; aneurysm; hemodynamic; 4D flow MRI; reproducibility; WALL SHEAR-STRESS; VALVE; QUANTIFICATION; ACCURACY; DIAMETER; PATTERNS; VELOCITY; SIZE;
D O I
10.3390/app12083912
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
(1) Background: Aorta hemodynamics have been associated with aortic remodeling, but the reproducibility of its assessment has been evaluated marginally in patients with thoracic aortic aneurysm (TAA). The current study evaluated intra- and interobserver reproducibility of 4D flow MRI-derived hemodynamic parameters (normalized flow displacement, flow jet angle, wall shear stress (WSS) magnitude, axial WSS, circumferential WSS, WSS angle, vorticity, helicity, and local normalized helicity (LNH)) in TAA patients; (2) Methods: The thoracic aorta of 20 patients was semi-automatically segmented on 4D flow MRI data in 5 systolic phases by 3 different observers. Each time-dependent segmentation was manually improved and partitioned into six anatomical segments. The hemodynamic parameters were quantified per phase and segment. The coefficient of variation (COV) and intraclass correlation coefficient (ICC) were calculated; (3) Results: A total of 2400 lumen segments were analyzed. The mean aneurysm diameter was 50.8 +/- 2.7 mm. The intra- and interobserver analysis demonstrated a good reproducibility (COV = 16-30% and ICC = 0.84-0.94) for normalized flow displacement and jet angle, a very good-to-excellent reproducibility (COV = 3-26% and ICC = 0.87-1.00) for all WSS components, helicity and LNH, and an excellent reproducibility (COV = 3-10% and ICC = 0.96-1.00) for vorticity; (4) Conclusion: 4D flow MRI-derived hemodynamic parameters are reproducible within the thoracic aorta in TAA patients.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Characterization of Ascending Aortic Flow in Patients With Degenerative Aneurysms A 4D Flow Magnetic Resonance Study
    Ramaekers, Mitch J. F. G.
    Adriaans, Bouke P.
    Juffermans, Joe F.
    van Assen, Hans C.
    Bekkers, Sebastiaan C. A. M.
    Scholte, Arthur J. H. A.
    Kenjeres, Sasa
    Lamb, Hildo J.
    Wildberger, Joachim E.
    Westenberg, Jos J. M.
    Schalla, Simon
    INVESTIGATIVE RADIOLOGY, 2021, 56 (08) : 494 - 500
  • [2] Impact of Respiratory Gating on Hemodynamic Parameters from 4D Flow MRI
    Denecken, Esteban
    Sotelo, Julio
    Arrieta, Cristobal
    Andia, Marcelo E.
    Uribe, Sergio
    APPLIED SCIENCES-BASEL, 2022, 12 (06):
  • [3] Feasibility and reproducibility study in swine of 4D flow MRI to assess pulmonary vessels hemodynamic
    Faragli, A. Alessandro
    Lo Muzio, F. P.
    Huellebrand, M.
    Tanacli, R.
    Hennemuth, A.
    Alogna, A.
    Kelle, S.
    EUROPEAN JOURNAL OF HEART FAILURE, 2024, 26 : 641 - 641
  • [4] Automated aortic segmentation and quantification of hemodynamic parameters from 4D flow MRI using deep learning techniques
    Manokaran, Jenita
    Garcia, Julio
    Ukwatta, Eranga
    JOURNAL OF MEDICAL IMAGING, 2023, 10 (06)
  • [5] Visualizing and quantifying flow stasis in abdominal aortic aneurysms in men using 4D flow MRI
    Ziegler, Magnus
    Welander, Martin
    Lantz, Jonas
    Lindenberger, Marcus
    Bjarnegard, Niclas
    Karlsson, Matts
    Ebbers, Tino
    Lanne, Toste
    Dyverfeldt, Petter
    MAGNETIC RESONANCE IMAGING, 2019, 57 : 103 - 110
  • [6] Type of aortic valve replacement influences ascending aortic flow characteristics - a pilot study using 4D flow MRI
    Florian von Knobelsdorff-Brenkenhoff
    Ralf F Trauzeddel
    Alex J Barker
    Henriette Gruettner
    Michael Markl
    Jeanette Schulz-Menger
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [7] Reproducibility of quantitative analysis of aortic 4D flow data
    Petter Dyverfeldt
    Michael D Hope
    Monica Sigovan
    Jarrett Wrenn
    David Saloner
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [8] 4D Flow MRI Applications for Aortic Disease
    Burris, Nicholas S.
    Hope, Michael D.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2015, 23 (01) : 15 - +
  • [9] Characterization of cerebral aneurysms using 4D FLOW MRI
    Susanne Schnell
    Sameer A Ansari
    Parmede Vakil
    Michael Hurley
    James Carr
    Hunt Batjer
    Bernard R Bendok
    Timothy J Carroll
    Michael Markl
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [10] Automated hemodynamic assessment for cranial 4D flow MRI
    Roberts, Grant S.
    Hoffman, Carson A.
    Rivera-Rivera, Leonardo A.
    Berman, Sara E.
    Eisenmenger, Laura B.
    Wieben, Oliver
    MAGNETIC RESONANCE IMAGING, 2023, 97 : 46 - 55