Reliability and accuracy of MRI scanogram in the evaluation of limb length discrepancy

被引:33
|
作者
Leitzes, AH
Potter, HG
Amaral, T
Marx, RG
Lyman, S
Widmann, RE
机构
[1] Cornell Univ, Hosp Special Surg, Weill Med Coll, New York, NY 10021 USA
[2] Cornell Univ, Hosp Special Surg, Weill Med Coll, Dept Radiol, New York, NY 10021 USA
[3] Montefiore Hosp, Dept Pediat Orthopaed, Bronx, NY USA
[4] Cornell Univ, Hosp Special Surg, Weill Med Coll, Foster Ctr Clin Outcome Res, New York, NY 10021 USA
[5] Cornell Univ, Hosp Special Surg, Weill Med Coll, Dept Pediat Orthopaed Surg, New York, NY 10021 USA
关键词
limb length discrepancy; radiographic scanogram; CT scanogram;
D O I
10.1097/01.bpo.0000173246.12184.a5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to compare MRI scanogram with traditional radiographic methods for measurement of limb length. The authors hypothesized that MRI scanogram would be as reliable and accurate as radiographic scanogram in measurement of limb length without exposing patients to ionizing radiation. Twelve cadaveric femurs were measured using AP conventional radiographic scanogram, CT scanogram, MRI scanogram, and electronic caliper. Three orthopaedists performed two separate measurements using each technique. Intraobserver and interobserver variability was assessed for each of the three radiographic techniques. Accuracy was assessed by comparison of radiographic measurements to electronic caliper measurements of femur length. The reliability of all three radiographic limb length measurement techniques was excellent (ICC > 0.99). The accuracy of plain radiographic scanogram was slightly superior to CT scanogram and MRI scanogram. The mean absolute differences for radiographic, CT, and MRI scanograms compared with the gold standard, direct caliper measurement, were 0.52 mm, 0.68 mm, and 2.90 mm, respectively. All three scanogram techniques showed excellent reliability and accuracy. Radiographic scanogram remains the gold standard for leg length measurement. MRI scanogram is slightly less accurate compared with radiographic scanogram, but it does not use ionizing radiation. MRI scanogram merits clinical study and comparison with the traditional radiographic scanogram method for measurement of limb length.
引用
收藏
页码:747 / 749
页数:3
相关论文
共 50 条
  • [41] The Assessment of Limb Length Discrepancy Before Total Hip Arthroplasty
    Tipton, Shane C.
    Sutherland, John K.
    Schwarzkopf, Ran
    JOURNAL OF ARTHROPLASTY, 2016, 31 (04): : 888 - 892
  • [42] Total knee arthroplasty: Limb length discrepancy and functional outcome
    Vaidya, Shrinand V.
    Patel, Mihir R.
    Panghate, Atul N.
    Rathod, Parthiv A.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2010, 44 (03) : 300 - 307
  • [43] Limb-length Discrepancy After Total Hip Arthroplasty
    Harwin, Steven F.
    Pivec, Robert
    ORTHOPEDICS, 2014, 37 (02) : 78 - 79
  • [44] Meralgia paresthetica secondary to limb length discrepancy: Case report
    Goel, A
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1999, 80 (03): : 348 - 349
  • [45] Treatment of limb length discrepancy following total hip arthroplasty
    Kayani, Babar
    Pietrzak, Jurek
    Donaldson, Matthew J.
    Konan, Sujith
    Haddad, Fares S.
    BRITISH JOURNAL OF HOSPITAL MEDICINE, 2017, 78 (11) : 633 - 637
  • [46] EARLY EXPERIENCE WITH EPIPHYSEAL DISTRACTION IN THE MANAGEMENT OF LIMB LENGTH DISCREPANCY
    EMERY, RJH
    JONES, CB
    AICHROTH, PM
    DEWAR, M
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01): : 154 - 154
  • [47] Total knee arthroplasty: Limb length discrepancy and functional outcome
    Shrinand V. Vaidya
    Mihir R. Patel
    Atul N. Panghate
    Parthiv A. Rathod
    Indian Journal of Orthopaedics, 2010, 44 : 300 - 307
  • [48] CORRELATION BETWEEN LIMB LENGTH DISCREPANCY AND ASYMMETRICAL REARFOOT POSITION
    BLAKE, RL
    FERGUSON, HJ
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 1993, 83 (11): : 625 - 633
  • [49] LOWER LIMB-LENGTH DISCREPANCY - AN EPIDEMIOLOGIC-STUDY
    GUICHET, JM
    SPIVAK, JM
    TROUILLOUD, P
    GRAMMONT, PM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1991, (272) : 235 - 241
  • [50] LIMB LENGTH DISCREPANCY - IDENTIFICATION, CLINICAL-SIGNIFICANCE, AND MANAGEMENT
    BLUSTEIN, SM
    DAMICO, JC
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 1985, 75 (04) : 200 - 206