Reliability and accuracy of MRI scanogram in the evaluation of limb length discrepancy

被引:33
|
作者
Leitzes, AH
Potter, HG
Amaral, T
Marx, RG
Lyman, S
Widmann, RE
机构
[1] Cornell Univ, Hosp Special Surg, Weill Med Coll, New York, NY 10021 USA
[2] Cornell Univ, Hosp Special Surg, Weill Med Coll, Dept Radiol, New York, NY 10021 USA
[3] Montefiore Hosp, Dept Pediat Orthopaed, Bronx, NY USA
[4] Cornell Univ, Hosp Special Surg, Weill Med Coll, Foster Ctr Clin Outcome Res, New York, NY 10021 USA
[5] Cornell Univ, Hosp Special Surg, Weill Med Coll, Dept Pediat Orthopaed Surg, New York, NY 10021 USA
关键词
limb length discrepancy; radiographic scanogram; CT scanogram;
D O I
10.1097/01.bpo.0000173246.12184.a5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to compare MRI scanogram with traditional radiographic methods for measurement of limb length. The authors hypothesized that MRI scanogram would be as reliable and accurate as radiographic scanogram in measurement of limb length without exposing patients to ionizing radiation. Twelve cadaveric femurs were measured using AP conventional radiographic scanogram, CT scanogram, MRI scanogram, and electronic caliper. Three orthopaedists performed two separate measurements using each technique. Intraobserver and interobserver variability was assessed for each of the three radiographic techniques. Accuracy was assessed by comparison of radiographic measurements to electronic caliper measurements of femur length. The reliability of all three radiographic limb length measurement techniques was excellent (ICC > 0.99). The accuracy of plain radiographic scanogram was slightly superior to CT scanogram and MRI scanogram. The mean absolute differences for radiographic, CT, and MRI scanograms compared with the gold standard, direct caliper measurement, were 0.52 mm, 0.68 mm, and 2.90 mm, respectively. All three scanogram techniques showed excellent reliability and accuracy. Radiographic scanogram remains the gold standard for leg length measurement. MRI scanogram is slightly less accurate compared with radiographic scanogram, but it does not use ionizing radiation. MRI scanogram merits clinical study and comparison with the traditional radiographic scanogram method for measurement of limb length.
引用
收藏
页码:747 / 749
页数:3
相关论文
共 50 条
  • [21] Gait asymmetry in patients with limb length discrepancy
    Perttunen, JR
    Anttila, E
    Södergård, J
    Merikanto, J
    Komi, PV
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2004, 14 (01) : 49 - 56
  • [22] Limb shortening for the management of leg length discrepancy
    Coppola, C
    Maffulli, N
    JOURNAL OF THE ROYAL COLLEGE OF SURGEONS OF EDINBURGH, 1999, 44 (01): : 46 - 54
  • [23] Inter-limb difference of mechanical work in limb length discrepancy
    Song, Mi Hyun
    Song, Hae-Ryong
    Kim, Woo-Sub
    GAIT & POSTURE, 2021, 84 : 79 - 86
  • [24] LENGTHENING OF THE HUMERUS FOR UPPER EXTREMITY LIMB LENGTH DISCREPANCY
    SCHOPLER, SA
    LAWRENCE, JF
    JOHNSON, MK
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1986, 6 (04) : 477 - 480
  • [25] Distraction osteogenesis in congenital limb length discrepancy: A review
    Maffuli, N
    Fixsen, JA
    JOURNAL OF THE ROYAL COLLEGE OF SURGEONS OF EDINBURGH, 1996, 41 (04): : 258 - 264
  • [26] Limb-Length Discrepancy as a Cause of Plantar Fasciitis
    Mahmood, Sadia
    Huffman, Lanie K.
    Harris, John G.
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2010, 100 (06) : 452 - 455
  • [27] The prenatal multiplier method for prediction of limb length discrepancy
    Paley, J
    Gelman, A
    Paley, D
    Herzenberg, JE
    PRENATAL DIAGNOSIS, 2005, 25 (06) : 435 - 438
  • [28] Evaluation of the reliability and accuracy of MRI for the diagnosis of meniscal ramp lesions
    Menendez, Sara Escoda
    Gonzalez, Pedro Garcia
    Moris, Ana Rosa Meana
    Soto, Miguel Del Valle
    Fernandez, Antonio Maestro
    ACTA RADIOLOGICA, 2024, 65 (11) : 1382 - 1389
  • [29] Correction of limb length discrepancy after tibialization of the fibula
    Kumar, Narinder
    Chaudhry, Amit
    CURRENT ORTHOPAEDIC PRACTICE, 2018, 29 (01): : 90 - 92
  • [30] Prevention of limb length discrepancy in total hip arthroplasty
    Kayani, Babar
    Pietrzak, Jurek
    Hossain, Fahad S.
    Konan, Sujith
    Haddad, Fares S.
    BRITISH JOURNAL OF HOSPITAL MEDICINE, 2017, 78 (07) : 385 - 390