Reliability and accuracy of MRI scanogram in the evaluation of limb length discrepancy

被引:33
|
作者
Leitzes, AH
Potter, HG
Amaral, T
Marx, RG
Lyman, S
Widmann, RE
机构
[1] Cornell Univ, Hosp Special Surg, Weill Med Coll, New York, NY 10021 USA
[2] Cornell Univ, Hosp Special Surg, Weill Med Coll, Dept Radiol, New York, NY 10021 USA
[3] Montefiore Hosp, Dept Pediat Orthopaed, Bronx, NY USA
[4] Cornell Univ, Hosp Special Surg, Weill Med Coll, Foster Ctr Clin Outcome Res, New York, NY 10021 USA
[5] Cornell Univ, Hosp Special Surg, Weill Med Coll, Dept Pediat Orthopaed Surg, New York, NY 10021 USA
关键词
limb length discrepancy; radiographic scanogram; CT scanogram;
D O I
10.1097/01.bpo.0000173246.12184.a5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to compare MRI scanogram with traditional radiographic methods for measurement of limb length. The authors hypothesized that MRI scanogram would be as reliable and accurate as radiographic scanogram in measurement of limb length without exposing patients to ionizing radiation. Twelve cadaveric femurs were measured using AP conventional radiographic scanogram, CT scanogram, MRI scanogram, and electronic caliper. Three orthopaedists performed two separate measurements using each technique. Intraobserver and interobserver variability was assessed for each of the three radiographic techniques. Accuracy was assessed by comparison of radiographic measurements to electronic caliper measurements of femur length. The reliability of all three radiographic limb length measurement techniques was excellent (ICC > 0.99). The accuracy of plain radiographic scanogram was slightly superior to CT scanogram and MRI scanogram. The mean absolute differences for radiographic, CT, and MRI scanograms compared with the gold standard, direct caliper measurement, were 0.52 mm, 0.68 mm, and 2.90 mm, respectively. All three scanogram techniques showed excellent reliability and accuracy. Radiographic scanogram remains the gold standard for leg length measurement. MRI scanogram is slightly less accurate compared with radiographic scanogram, but it does not use ionizing radiation. MRI scanogram merits clinical study and comparison with the traditional radiographic scanogram method for measurement of limb length.
引用
收藏
页码:747 / 749
页数:3
相关论文
共 50 条
  • [1] Reliability analysis for radiographic measurement of limb length discrepancy - Full-length standing anteroposterior radiograph versus scanogram
    Sabharwal, Sanjeev
    Zhao, Caixia
    McKeon, John
    Melaghari, Todd
    Blacksin, Marcia
    Wenekor, Cornelia
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2007, 27 (01) : 46 - 50
  • [2] Should full-length standing anteroposterior radiographs replace the scanogram for measurement of limb length discrepancy?
    Machen, MS
    Stevens, PM
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2005, 14 (01): : 30 - 37
  • [3] CT scanogram for limb length discrepancy in comminuted femoral shaft fractures following IM nailing
    Vaidya, Rahul
    Anderson, Brent
    Elbanna, Ashraf
    Colen, Robert
    Hoard, Daniel
    Sethi, Anil
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (07): : 1176 - 1181
  • [4] Computed radiographic measurement of limb-length discrepancy - Full-length standing anteroposterior radiograph compared with scanogram
    Sabharwal, Sanjeev
    Zhao, Caixia
    McKeon, John J.
    McClemens, Emily
    Edgar, Michele
    Behrens, Fred
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (10): : 2243 - 2251
  • [5] Plotting Fibular Length for Children with Leg Length Discrepancy Using CT Scanogram
    McGoldrick, N. P.
    Olajide, K.
    Noel, J.
    Kiely, P.
    Moore, D. P.
    Kelly, P.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2014, 183 : S260 - S261
  • [6] The reliability of computed tomography scanograms in the measurement of limb length discrepancy
    Poutawera, Vaughan
    Stott, Ngaire Susan
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2010, 19 (01): : 42 - 46
  • [7] Limb length discrepancy
    Dahl, MT
    PEDIATRIC CLINICS OF NORTH AMERICA, 1996, 43 (04) : 849 - &
  • [8] A baby with limb length discrepancy
    Siddiqui, Yasir S.
    Pathania, Ved P.
    SAUDI MEDICAL JOURNAL, 2012, 33 (03) : 328 - 329
  • [9] Measurement of leg length discrepancy after total hip arthroplasty. The reliability of a plain radiographic method compared to CT-scanogram
    Martin Kjellberg
    Bariq Al-Amiry
    Erling Englund
    Göran O. Sjödén
    Arkan S. Sayed-Noor
    Skeletal Radiology, 2012, 41 : 187 - 191
  • [10] LOWER LIMB-LENGTH DISCREPANCY
    SIFFERT, RS
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1987, 69A (07): : 1100 - 1106