On the vectorial calibration of a vibrating sample magnetometer for thin film measurements

被引:8
|
作者
Bolhuis, T
Abelmann, L
Lodder, JC
Samwel, EO
机构
[1] Univ Twente, MESA Res Inst, NL-7500 AE Enschede, Netherlands
[2] ADE Technol Inc, Digital Measurement Syst Div, Newton, MA 02166 USA
关键词
calibration; vector VSM; cross talk; thin film; demagnetisation; ME-tape;
D O I
10.1016/S0304-8853(98)00451-X
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A calibration method for the biaxial vector Vibrating Sample Magnetometer (VSM) is proposed to reduce the so-called cross talk' error, often observed during angular measurements on magnetic thin films. The coil system of the biaxial vector VSM consists of two sets of coils, one for each of the two co-ordinate axes. The method takes into account that each coil set is sensitive to all components of the magnetisation vector and moreover that the sensitivity to the components parallel and perpendicular to the film plane can be different. A correction for demagnetisation should be used to compensate the fact that the sample used for the calibration cannot be fully saturated with an applied field at angles close to the normal of the film plane. Curve-fitting on the sensitivity curves is used to reduce noise. These procedures result in a calibration which reduces the cross talk by a factor 4-8 depending on the coil configuration and the size and shape of the samples used. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:332 / 336
页数:5
相关论文
共 50 条
  • [31] Design of a compensated signal rod for low magnetic moment sample measurements with a vibrating sample magnetometer
    Carignan, Louis-Philippe
    Cochrane, Robert W.
    Menard, David
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (03):
  • [32] APPLICATION OF A VIBRATING SAMPLE MAGNETOMETER TO MAGNETIC MEASUREMENTS UNDER HYDROSTATIC-PRESSURE
    GUERTIN, RP
    FONER, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1974, 45 (06): : 863 - 864
  • [33] Virtual additive moments measured by a vibrating sample magnetometer on superconducting thin films
    Pust, L
    Dlouhy, D
    Jirsa, M
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1996, 9 (09): : 814 - 821
  • [34] Reduced order modeling and optimization of the magnetic thin film vibrating beam magnetometer
    Perrier, T.
    Levy, R.
    Kayser, P.
    Verlhac, B.
    Lavenus, P.
    Moulin, J.
    2017 SYMPOSIUM ON DESIGN, TEST, INTEGRATION AND PACKAGING OF MEMS/MOEMS (DTIP 2017), 2017,
  • [35] On the calibration of a vectorial 4He pumped magnetometer
    Gravrand, O
    Khokhlov, A
    Le Mouël, JL
    Léger, JM
    EARTH PLANETS AND SPACE, 2001, 53 (10): : 949 - 958
  • [36] On the calibration of a vectorial 4He pumped magnetometer
    O. Gravrand
    A. Khokhlov
    J. L. Le Mouël
    J. M. Léger
    Earth, Planets and Space, 2001, 53 : 949 - 958
  • [37] Vibrating sample magnetometer for large permanent magnets
    Ribeiro, A. Lopes
    2007 AFRICON, VOLS 1-3, 2007, : 665 - 668
  • [38] FURTHER IMPROVEMENTS IN VIBRATING SAMPLE MAGNETOMETER SENSITIVITY
    FONER, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1975, 46 (10): : 1425 - 1426
  • [39] VIBRATING SAMPLE MAGNETOMETER FOR USE WITH A SUPERCONDUCTING MAGNET
    SPRINGFORD, M
    STOCKTON, JR
    WAMPLER, WR
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1971, 4 (NDEC): : 1036 - +
  • [40] A magnetization measuring instrument - Vibrating Sample Magnetometer
    Zhao Ruijuan
    An Panlong
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 870 - 873