Monte Carlo investigation of the effects of an IMRT compensator on linear accelerator beam output

被引:0
|
作者
Niven, D.
Lewis, J.
机构
[1] Univ Manitoba, Winnipeg, MB, Canada
[2] CancerCare Manitoba, Winnipeg, MB, Canada
关键词
D O I
10.1118/1.2761388
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A comparison between Pinnacle calculated and Monte Carlo dose distributions was performed for patient treatments implementing physical compensators to deliver intensity modulated radiation therapy (IMRT). Method and Materials: Two 3D conformal radiation treatment (CRT) plans were created in Pinnacle using targets placed in the head and neck region of an anthropomorphic phantom. Compensators were generated in Pinnacle and were also modeled in DOSXYZnrc. Dose was calculated in both Pinnacle and Monte Carlo for cases with and without the compensator, and the dose distributions were compared using the chi‐comparison test with tolerances set to a 3% dose difference and a 3 mm distance‐to‐agreement. The dose distributions in the presence of a compensator were also compared for one beam of a five‐field IMRT treatment plan generated using actual patient CT data. Results: For the two 3D CRT plans, the number of voxels which failed the chi‐comparison criteria increased when the compensator was included in the simulations. In a (15 × 15 × 15) cm3 volume centered on the target, the percentage of voxels in disagreement rose from 4.99% to 9.46% for the first plan and from 4.60% to 5.19% for the second plan. For the IMRT plan with a compensator, the number of voxels failing the chi‐comparison test in a (10 × 10 × 10) cm3 volume centered on the target was 4.14%. Conclusion: The results demonstrate that dose calculations performed by Pinnacle in the presence of compensators are not necessarily representative of the dose delivered to the patient. This can be attributed to the fact in calculating the dose through the compensator during the compensator thickness optimization, Pinnacle accounts only for the attenuation of the primary fluence and does not consider scatter or beam hardening effects. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2559 / 2559
页数:1
相关论文
共 50 条
  • [41] Fast Monte Carlo calculation of linear accelerator head scatter factors
    MacPherson, M
    Badeen, A
    Wilkins, D
    Gerig, L
    MEDICAL PHYSICS, 2002, 29 (06) : 1203 - 1203
  • [42] Monte Carlo modeling of dynamic tumor tracking on a gimbaled linear accelerator
    Carpentier, Emilie E.
    Mcdermott, Ronan L.
    Su, Shiqin
    Rostamzadeh, Maryam
    Popescu, I. Antoniu
    Bergman, Alanah M.
    Mestrovic, Ante
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (01) : 50 - 58
  • [43] Monte Carlo simulation of a medical linear accelerator for filtered and FFF systems
    Yazǧan C.
    Eçen Y.C.
    Yazǧan, Çaǧr (cagri.yazgan@gmail.com), 2017, TUBITAK (41): : 498 - 506
  • [44] EURADOS intercomparison exercise on Monte Carlo modelling of a medical linear accelerator
    Caccia, Barbara
    Le Roy, Maiwenn
    Blideanu, Valentin
    Andenna, Claudio
    Arun, Chairmadurai
    Czarnecki, Damian
    El Bardouni, Tarek
    Gschwind, Regine
    Huot, Nicolas
    Martin, Eric
    Zink, Klemens
    Zoubair, Mariam
    Price, Robert
    de Carlan, Loic
    ANNALI DELL ISTITUTO SUPERIORE DI SANITA, 2017, 53 (04): : 314 - 321
  • [45] On Advanced Monte Carlo Methods for Linear Algebra on Advanced Accelerator Architectures
    Lebedev, Anton
    Alexandrov, Vassil
    SCALA 2018: PROCEEDINGS OF 2018 IEEE/ACM 9TH WORKSHOP ON LATEST ADVANCES IN SCALABLE ALGORITHMS FOR LARGE-SCALE SYSTEMS (SCALA), 2018, : 81 - 90
  • [46] Monte Carlo study on a new concept of a scanning photon beam system for IMRT
    Wysocka-Rabin, Anna M.
    Hartmann, Guenter H.
    NUKLEONIKA, 2011, 56 (04) : 291 - 297
  • [47] The effects of compensator design on scatter distribution and magnitude: A Monte Carlo study
    Bootsma, G. J.
    Verhaegen, F.
    Jaffray, D. A.
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [48] Benchmarking of Monte Carlo model of Siemens Oncor® linear accelerator for 18 MV photon beam: Determination of initial electron beam parameters
    Najafzadeh, Milad
    Hoseini-Ghafarokhi, Mojtaba
    Bolagh, Rezgar Shahi Mayn
    Haghparast, Mohammad
    Zarifi, Shiva
    Nickfarjam, Abolfazl
    Farhood, Bagher
    Chow, James C. L.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (06) : 1047 - 1070
  • [49] A Monte Carlo Investigation of a Novel Detector Arrangement for the Energy Spectrum Measurement of a 6MV Linear Accelerator
    Taneja, S.
    Bartol, L.
    Culberson, W.
    DeWerd, L.
    MEDICAL PHYSICS, 2016, 43 (06) : 3869 - 3869
  • [50] Photon spectra of a linear accelerator in a water phantom:: Investigation of the field size dependence via Monte Carlo simulation
    Schoenig, F.
    Wulff, J.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S412 - S412