Low-Dose 3D Rotational Angiography in Measuring the Size of Intracranial Aneurysm: In Vitro Feasibility Study Using Aneurysm Phantom

被引:2
|
作者
Ki, Hee Jong [1 ]
Kim, Bum-Soo [2 ]
Kim, Jun-Ki
Choi, Jai Ho [1 ]
Shin, Yong Sam [1 ]
Choi, Yangsean [2 ]
Shin, Na-Young [2 ]
Jang, Jinhee [2 ]
Ahn, Kook-jin [2 ]
机构
[1] Catholic Univ Korea, Seoul St Marys Hosp, Dept Neurosurg, Seoul, South Korea
[2] Catholic Univ Korea, Seoul St Marys Hosp, Dept Radiol, Seoul, South Korea
关键词
Cerebral angiography; Radiation dosage; Intracranial aneurysm;
D O I
10.5469/neuroint.2020.00437
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose: Three-dimensional (3D) measurement of intracranial aneurysms is important in planning endovascular treatment, and 3D rotational angiography (RA) is effective in accurate measurement. The purpose of this study was to evaluate the feasibility of low dose 3D RA (5 seconds 0.10 mu Gy/frame) in measuring an intracranial aneurysm using an in vitro phantom. Materials and Methods: We investigated an in vitro 3D phantom of an intracranial aneurysm with 10 acquisitions of 3D RA with a conventional dose (5 seconds 0.36 mu Gy/frame) and 10 acquisitions with a low-dose (5 seconds 0.10 mu Gy/frame). 3D size and neck diameters of the aneurysm were measured and compared between the 2 groups (conventional and low-dose) using noninferiority statistics. Results: The aneurysm measurements were well-correlated between the 2 readers, and noninferiority in the measurement of aneurysmal size of low-dose 3D RA was demonstrated, as the upper margin of the 1-sided 97.5% confidence interval did not cross the pre-defined noninferiority margin of 0.2 mm by the 2 readers. Conclusion: Low-dose (5 seconds 0.10 mu Gy/frame) cerebral 3D RA is technically feasible and not inferior in in vitro 3D measurement of an intracranial aneurysm. Thus, low-dose 3D RA is promising and needs further evaluation for its clinical utility in the planning of endovascular treatment of an intracranial aneurysm.
引用
收藏
页码:59 / 63
页数:5
相关论文
共 50 条
  • [41] Feasibility Study of Block-Matching and 3D Filtering Algorithm in Low-Dose CT Image with Tin Filter
    Song, Mingyu
    Kim, Minsu
    Lim, Junsoo
    Chun, Donghwan
    Park, Minji
    Shim, Jina
    Lee, Youngjin
    JOURNAL OF MAGNETICS, 2023, 28 (01) : 56 - 63
  • [42] Dual-Energy CT Angiography in the Evaluation of Intracranial Aneurysms: Image Quality, Radiation Dose, and Comparison With 3D Rotational Digital Subtraction Angiography
    Zhang, Long-Jiang
    Wu, Sheng-Yong
    Niu, Jing-Bo
    Zhang, Zhuo-Li
    Wang, Henry Z.
    Zhao, Yan-E
    Chai, Xue
    Zhou, Chang-Sheng
    Lu, Guang-Ming
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (01) : 23 - 30
  • [43] Patient-Specific Computational Hemodynamics of Intracranial Aneurysms from 3D Rotational Angiography and CT Angiography: An In Vivo Reproducibility Study
    Geers, A. J.
    Larrabide, I.
    Radaelli, A. G.
    Bogunovic, H.
    Kim, M.
    van Andel, H. A. F. Gratama
    Majoie, C. B.
    VanBavel, E.
    Frangi, A. F.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (03) : 581 - 586
  • [44] Rapid sequence angiography with a 3D printed aneurysm phantom and an ultra-high frame rate imaging photon counting detector (PCD)
    Shankar, A.
    Krebs, J.
    Bednarek, D. R.
    Rudin, S.
    MEDICAL IMAGING 2019: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2019, 10953
  • [45] Reconstruction of 3D Abdominal Aorta Aneurysm from Computed Tomographic Angiography Using 3D U-Net Deep Learning Network
    Kongrat, Siriporn
    Pintavirooj, Chuchart
    Tungjitkusolmun, Supan
    2022 14TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2022), 2022,
  • [46] Assessment of Interrater Reliability and Accuracy of Cerebral Aneurysm Morphometry Using 3D Virtual Reality, 2D Digital Subtraction Angiography, and 3D Reconstruction: A Randomized Comparative Study
    Saemann, Attill
    de Wilde, Daniel
    Rychen, Jonathan
    Roethlisberger, Michel
    Zelechowski, Marek
    Faludi, Balazs
    Cattin, Philippe Claude
    Psychogios, Marios-Nikos
    Soleman, Jehuda
    Guzman, Raphael
    BRAIN SCIENCES, 2024, 14 (10)
  • [47] Rehearsals using patient-specific 3D-printed aneurysm models for simulation of endovascular embolization of complex intracranial aneurysms: 3D SIM study
    Le Bras, Anthony
    Boustia, Fakhreddine
    Janot, Kevin
    Le Pabic, Estelle
    Ouvrard, Mathilde
    Fougerou-Leurent, Claire
    Ferre, Jean-Christophe
    Gauvrit, Jean-Yves
    Eugene, Francois
    JOURNAL OF NEURORADIOLOGY, 2023, 50 (01) : 86 - 92
  • [48] Low-dose radiation protocol using 3D mode in a BGO PET/CT
    Solange A. Nogueira
    Renato Dimenstein
    Marcelo L. Cunha
    Jairo Wagner
    Marcelo B. G. Funari
    Henrique M. Lederman
    La radiologia medica, 2015, 120 : 251 - 255
  • [49] Evaluating a 3D deep learning pipeline for cerebral vessel and intracranial aneurysm segmentation from computed tomography angiography-digital subtraction angiography image pairs
    Patel, Tatsat R.
    Patel, Aakash
    Veeturi, Sricharan S.
    Shah, Munjal
    Waqas, Muhammad
    Monteiro, Andre
    Baig, Ammad A.
    Pinter, Nandor
    Levy, Elad I.
    Siddiqui, Adnan H.
    Tutino, Vincent M.
    NEUROSURGICAL FOCUS, 2023, 54 (06)
  • [50] Low-dose radiation protocol using 3D mode in a BGO PET/CT
    Nogueira, Solange A.
    Dimenstein, Renato
    Cunha, Marcelo L.
    Wagner, Jairo
    Funari, Marcelo B. G.
    Lederman, Henrique M.
    RADIOLOGIA MEDICA, 2015, 120 (02): : 251 - 255