Objective quantification of lens nuclear opacities using swept-source anterior segment optical coherence tomography

被引:12
|
作者
Wang, Wei [1 ]
Zhang, Jiaqing [1 ]
Gu, Xiaoxun [1 ]
Ruan, Xiaoting [1 ]
Chen, Xiaoyun [1 ]
Tan, Xuhua [1 ]
Jin, Guangming [1 ]
Wang, Lanhua [1 ]
He, Mingguang [1 ,2 ]
Congdon, Nathan [1 ,3 ]
Liu, Zhenzhen [1 ]
Luo, Lixia [1 ]
Liu, Yizhi [1 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, Guangzhou 510623, Peoples R China
[2] Univ Melbourne, Ctr Eye Res Australia, Melbourne, Vic, Australia
[3] Queens Univ Belfast, Ctr Publ Hlth, Belfast, Antrim, North Ireland
基金
中国国家自然科学基金;
关键词
lens and zonules; CLASSIFICATION-SYSTEM-III; CLINICAL-APPLICATION;
D O I
10.1136/bjophthalmol-2020-318334
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background/aims The primary objective is to quantify the lens nuclear opacity using swept-source anterior segment optical coherence tomography (SS-ASOCT) and to evaluate its correlations with Lens Opacities Classification System III (LOCS-III) system and surgical parameters. The secondary objective is to assess the diagnostic performance for hard nuclear cataract. Methods This cross-sectional study included 1222 patients eligible for cataract surgery (1222 eyes). The latest SS-ASOCT (CASIA-2) was used to obtain high-resolution lens images, and the average nuclear density (AND) and maximum nuclear density (MND) were measured by a custom ImageJ software. Spearman's correlations analysis was used to assess associations of AND/MND with LOCS-III nuclear scores, visual acuity and surgical parameters. The subjects were then split randomly (9:1) into the training dataset and validating dataset. Receiver operating characteristic curves and calibration curves were constructed for the classification on hard nuclear cataract. Results The AND and MND from SS-ASOCT images were significantly correlated with nuclear colour scores (AND: r=0.716; MND: r=0.660; p<0.001) and nuclear opalescence scores (AND: r=0.712; MND: r=0.655; p<0.001). The AND by SS-ASOCT images had the highest values of Spearman's r for preoperative corrected distance visual acuity (r=0.3131), total ultrasonic time (r=0.3481) and cumulative dissipated energy (r=0.4265). The nuclear density had good performance in classifying hard nuclear cataract, with area under the curves of 0.859 (0.831-0.886) for AND and 0.796 (0.768-0.823) for MND. Conclusion Objective and quantitative evaluation of the lens nuclear density using SS-ASOCT images enable accurate diagnosis of hard nuclear cataract.
引用
收藏
页码:790 / 794
页数:5
相关论文
共 50 条
  • [31] Accuracy and Repeatability of an Anterior Segment Swept-Source Optical Coherence Tomographer
    Peguda, Rajini
    Kang, Pauline
    Maseedupally, Vinod
    Swarbrick, Helen
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 : S300 - S306
  • [32] Impact and Correction of an Anterior Phakic Intraocular Lens on Swept-Source Optical Coherence Tomography Biometry
    Ribeiro, Bruno Barbosa
    Monteiro, Silvia
    Marques, Joao Heitor
    Abreu, Ana Carolina
    Pinto, Maria do Ceu
    JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (08) : e562 - e568
  • [33] Determination of iris thickness development in children using swept-source anterior-segment optical coherence tomography
    Nakakura, Shunsuke
    Nagata, Yuki
    Shimizu, Yukiko
    Kawai, Akiko
    Tabuchi, Hitoshi
    Kiuchi, Yoshiaki
    PLOS ONE, 2019, 14 (05):
  • [34] Anterior Vitreous Objective Assessment in Uveitis: An Anterior Segment Swept Source Optical Coherence Tomography Study
    Invernizzi, Alessandro
    Zaffalon, Chiara
    Manni, Priscilla
    Zicarelli, Federico
    Chisari, Domenico
    Adani, Chantal
    Mastrofilippo, Valentina
    Bolletta, Elena
    Gozzi, Fabrizio
    De Simone, Luca
    Staurenghi, Giovanni
    Cimino, Luca
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2025, 33 (01) : 24 - 32
  • [35] Dynamic assessment of variations in pupil diameter using swept-source anterior segment optical coherence tomography after phakic collamer lens implantation
    Felix Gonzalez-Lopez
    Carmen Bouza-Miguens
    Victor Tejerina
    Vasyl Druchkiv
    Blas Mompean
    Julio Ortega-Usobiaga
    Rafael Bilbao-Calabuig
    Eye and Vision, 8
  • [36] Dynamic assessment of variations in pupil diameter using swept-source anterior segment optical coherence tomography after phakic collamer lens implantation
    Gonzalez-Lopez, Felix
    Bouza-Miguens, Carmen
    Tejerina, Victor
    Druchkiv, Vasyl
    Mompean, Blas
    Ortega-Usobiaga, Julio
    Bilbao-Calabuig, Rafael
    EYE AND VISION, 2021, 8 (01)
  • [37] Anterior scleral thickness dimensions by swept-source optical coherence tomography
    Ignacio Fernandez-Vigo, Jose
    Shi, Hang
    Burgos-Blasco, Barbara
    Fernandez-Aragon, Susana
    De-Pablo-Gomez-de-Liano, Lucia
    Kudsieh, Bachar
    Macarro-Merino, Ana
    Angel Fernandez-Vigo, Jose
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2022, 105 (01) : 13 - 19
  • [38] Prediction of postoperative intraocular lens tilt using swept-source optical coherence tomography
    Hirnschall, Nino
    Buehren, Tobias
    Bajramovic, Ferid
    Trost, Michael
    Teuber, Tanja
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (06): : 732 - 736
  • [39] Anterior segment swept-source optical coherence tomography and ultrasound biomicroscopy in iris and ciliary body lesions
    Mirzayev, Ibadulla
    Gunduz, Ahmet Kaan
    Gunduz, Omur Ozlenen
    Ates, Funda Seher Ozalp
    Heper, Aylin Okcu
    EXPERT REVIEW OF MEDICAL DEVICES, 2024, : 439 - 446
  • [40] Evaluation of lymphatic vessel dilatations by anterior segment swept-source optical coherence tomography: case report
    Volek, Eva
    Toth, Jeannette
    Nagy, Zoltan Zsolt
    Schneider, Miklos
    BMC OPHTHALMOLOGY, 2017, 17