Objective quantification of lens nuclear opacities using swept-source anterior segment optical coherence tomography

被引:12
|
作者
Wang, Wei [1 ]
Zhang, Jiaqing [1 ]
Gu, Xiaoxun [1 ]
Ruan, Xiaoting [1 ]
Chen, Xiaoyun [1 ]
Tan, Xuhua [1 ]
Jin, Guangming [1 ]
Wang, Lanhua [1 ]
He, Mingguang [1 ,2 ]
Congdon, Nathan [1 ,3 ]
Liu, Zhenzhen [1 ]
Luo, Lixia [1 ]
Liu, Yizhi [1 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, Guangzhou 510623, Peoples R China
[2] Univ Melbourne, Ctr Eye Res Australia, Melbourne, Vic, Australia
[3] Queens Univ Belfast, Ctr Publ Hlth, Belfast, Antrim, North Ireland
基金
中国国家自然科学基金;
关键词
lens and zonules; CLASSIFICATION-SYSTEM-III; CLINICAL-APPLICATION;
D O I
10.1136/bjophthalmol-2020-318334
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background/aims The primary objective is to quantify the lens nuclear opacity using swept-source anterior segment optical coherence tomography (SS-ASOCT) and to evaluate its correlations with Lens Opacities Classification System III (LOCS-III) system and surgical parameters. The secondary objective is to assess the diagnostic performance for hard nuclear cataract. Methods This cross-sectional study included 1222 patients eligible for cataract surgery (1222 eyes). The latest SS-ASOCT (CASIA-2) was used to obtain high-resolution lens images, and the average nuclear density (AND) and maximum nuclear density (MND) were measured by a custom ImageJ software. Spearman's correlations analysis was used to assess associations of AND/MND with LOCS-III nuclear scores, visual acuity and surgical parameters. The subjects were then split randomly (9:1) into the training dataset and validating dataset. Receiver operating characteristic curves and calibration curves were constructed for the classification on hard nuclear cataract. Results The AND and MND from SS-ASOCT images were significantly correlated with nuclear colour scores (AND: r=0.716; MND: r=0.660; p<0.001) and nuclear opalescence scores (AND: r=0.712; MND: r=0.655; p<0.001). The AND by SS-ASOCT images had the highest values of Spearman's r for preoperative corrected distance visual acuity (r=0.3131), total ultrasonic time (r=0.3481) and cumulative dissipated energy (r=0.4265). The nuclear density had good performance in classifying hard nuclear cataract, with area under the curves of 0.859 (0.831-0.886) for AND and 0.796 (0.768-0.823) for MND. Conclusion Objective and quantitative evaluation of the lens nuclear density using SS-ASOCT images enable accurate diagnosis of hard nuclear cataract.
引用
收藏
页码:790 / 794
页数:5
相关论文
共 50 条
  • [21] Screening for Subclinical Keratoconus Using Swept-Source Fourier Domain Anterior Segment Optical Coherence Tomography
    Steinberg, Johannes
    Casagrande, Maria K.
    Frings, Andreas
    Katz, Toam
    Druchkiv, Vasyl
    Richard, Gisbert
    Linke, Stephan J.
    CORNEA, 2015, 34 (11) : 1413 - 1419
  • [22] Comparison of Anterior Segment Measurements Between Swept-source Optical Coherence Tomography and Schiempflug Coherence Interferometer
    Song, Jiyun
    Na, Kyung Sun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (12): : 1158 - 1167
  • [23] Laser Lens Size Measurement Using Swept-Source Optical Coherence Tomography
    Jia, Pingping
    Zhao, Hong
    Qin, Yuwei
    APPLIED SCIENCES-BASEL, 2020, 10 (14):
  • [24] Metrics of Anterior Sclera in Normal Chinese Adults: Anterior Segment Imaging Using the Swept-Source Optical Coherence Tomography
    Lin, Na
    Sun, Yunqi
    Yang, Maoyuan
    Chen, Bichi
    Mao, Jieli
    Liu, Yongshun
    Deng, Ruzhi
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2024, 50 (01): : 23 - 28
  • [25] Comparison of Scheimpflug and swept-source anterior segment optical coherence tomography in normal and keratoconus eyes
    Seyed Mohammad Ghoreishi
    Seyed Ali Akbar Mortazavi
    Zahra-Alsadat Abtahi
    Mohammad-Ali Abtahi
    Seyed Ali Sonbolestan
    Seyed-Hossein Abtahi
    Mohadeseh Mohammadinia
    Kimia Nekouie Isfahani
    International Ophthalmology, 2017, 37 : 965 - 971
  • [26] Segmentation Errors in the Measurement of Volumetric Parameters by Swept-Source Anterior Segment Optical Coherence Tomography
    Chen, Hailiu
    Meng, Jie
    Lu, Peng
    Ye, Dan
    Li, Yunxuan
    Cheng, Lu
    Li, Yangyunhui
    Liang, Xiaoling
    Huang, Wenyong
    Huang, Jingjing
    FRONTIERS IN MEDICINE, 2021, 8
  • [27] Bilateral Acute Depigmentation of the Iris: Findings in Anterior Segment Swept-Source Optical Coherence Tomography
    Escribano Lopez, Patricia
    Jacobo Gonzalez-Guijarro, J.
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2019, 27 (08) : 1288 - 1292
  • [28] Anterior Segment Biometry During Accommodation and Effects of Cycloplegics by Swept-Source Optical Coherence Tomography
    Mitsukawa, Tadahiro
    Suzuki, Yumi
    Momota, Yosuke
    Suzuki, Shun
    Yamada, Masakazu
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 1237 - 1243
  • [29] Comparison of Scheimpflug and swept-source anterior segment optical coherence tomography in normal and keratoconus eyes
    Ghoreishi, Seyed Mohammad
    Mortazavi, Seyed Ali Akbar
    Abtahi, Zahra-Alsadat
    Abtahi, Mohammad-Ali
    Sonbolestan, Seyed Ali
    Abtahi, Seyed-Hossein
    Mohammadinia, Mohadeseh
    Isfahani, Kimia Nekouie
    INTERNATIONAL OPHTHALMOLOGY, 2017, 37 (04) : 965 - 971
  • [30] Quantitative assessment of lens opacities with anterior segment optical coherence tomography
    Wong, A. L.
    Leung, C. K-S
    Weinreb, R. N.
    Cheng, A. K. C.
    Cheung, C. Y. L.
    Lam, P. T-H
    Pang, C. P.
    Lam, D. S. C.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (01) : 61 - 65