ECG Gated Tomographic reconstruction for 3-D Rotational Coronary Angiography

被引:6
|
作者
Hu, Yining [1 ,4 ]
Xie, Lizhe [1 ,4 ]
Nunes, Jean Claude [2 ,5 ]
Bellanger, Jean Jacques [2 ,5 ]
Bedossa, Marc [2 ,3 ]
Toumoulin, Christine [2 ,4 ,5 ]
机构
[1] South East Univ, LIST, Nanjing 210096, Peoples R China
[2] Univ Rennes 1, Lab Traitment Signal Image, F-35000 Rennes, France
[3] CHU Rennes, Dept Cardiol Interventionelle, F-35033 Rennes, France
[4] Ctr Recherche Informat Biomed Sino Francais, F-35033 Rennes, France
[5] Natl Inst Hlth & Med Res INSERM, F-35000 Rennes, France
关键词
X-RAY ANGIOGRAPHY;
D O I
10.1109/IEMBS.2010.5627449
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A method is proposed for 3-D reconstruction of coronary from a limited number of projections in rotational angiography. A Bayesian maximum a posteriori (MAP) estimation is applied with a Poisson distributed projection to reconstruct the 3D coronary tree at a given instant of the cardiac cycle. Several regularizers are investigated L0-norm, L1 and L2-norm in order to take into account the sparsity of the data. Evaluations are reported on simulated data obtained from a 3D dynamic sequence acquired on a 64-slice GE LightSpeed CT scan. A performance study is conducted to evaluate the quality of the reconstruction of the structures.
引用
收藏
页码:3614 / 3617
页数:4
相关论文
共 50 条
  • [41] 3D multimodal cardiac data reconstruction using angiography and computerized tomographic angiography registration
    Tayebi, Rohollah Moosavi
    Wirza, Rahmita
    Sulaiman, Puteri S. B.
    Dimon, Mohd Zamrin
    Khalid, Fatimah
    Al-Surmi, Aqeel
    Mazaheri, Samaneh
    JOURNAL OF CARDIOTHORACIC SURGERY, 2015, 10
  • [42] 3D multimodal cardiac data reconstruction using angiography and computerized tomographic angiography registration
    Rohollah Moosavi Tayebi
    Rahmita Wirza
    Puteri S B Sulaiman
    Mohd Zamrin Dimon
    Fatimah Khalid
    Aqeel Al-Surmi
    Samaneh Mazaheri
    Journal of Cardiothoracic Surgery, 10
  • [43] Motion-compensated and gated cone beam filtered back-projection for 3-D rotational X-ray angiography
    Schäfer, D
    Borgert, J
    Rasche, V
    Grass, M
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) : 898 - 906
  • [44] COMPARISON OF TOMOGRAPHIC AND PLANAR GATED BLOOD POOL IMAGING AT REST WITH CORONARY ANGIOGRAPHY
    CORBETT, JR
    RELLAS, JS
    WILLERSON, JT
    NICOD, P
    SOKOLOV, J
    LEWIS, SE
    CIRCULATION, 1983, 68 (04) : 208 - 208
  • [45] Improved flow reconstruction in 3D rotational angiography (3DRA)
    Grass, A
    Suurmond, R
    Schmitt, H
    Heiland, S
    Haehnel, S
    Sartor, K
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1474 - 1476
  • [46] A comprehensive method for geometrically correct 3-D reconstruction of coronary arteries by fusion of intravascular ultrasound and biplane angiography
    Wahle, A
    Prause, GPM
    DeJong, SC
    Sonka, M
    COMPUTER-AIDED DIAGNOSIS IN MEDICAL IMAGING, 1999, 1182 : 363 - 368
  • [47] Towards a geometrically correct 3-D reconstruction of tortuous coronary arteries based on biplane angiography and intravascular ultrasound
    Guido P.M. Prause
    Steven C. DeJong
    Charles R. McKay
    Milan Sonka
    The International Journal of Cardiac Imaging, 1997, 13 : 451 - 462
  • [48] Towards a geometrically correct 3-D reconstruction of tortuous coronary arteries based on biplane angiography and intravascular ultrasound
    Prause, GPM
    DeJong, SC
    McKay, CR
    Sonka, M
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1997, 13 (06): : 451 - 462
  • [49] Automatic trinocular 3D reconstruction of coronary artery centerlines from rotational X-ray angiography
    Blondel, C
    Vaillant, R
    Devernay, F
    Malandain, G
    Ayache, N
    CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 832 - 837
  • [50] Reliability of computed tomographic angiography 3-D method of ruptured intracranial aneurysm measurements
    Wong, George K. C.
    Leung, Joyce H. Y.
    Yu, Janice W. L.
    Woo, Peter Y. M.
    Tan, Hai-Bin
    Siu, Deyond Y. W.
    Poon, Wai-Sang
    SURGICAL PRACTICE, 2013, 17 (03) : 97 - 100