ECG Gated Tomographic reconstruction for 3-D Rotational Coronary Angiography

被引:6
|
作者
Hu, Yining [1 ,4 ]
Xie, Lizhe [1 ,4 ]
Nunes, Jean Claude [2 ,5 ]
Bellanger, Jean Jacques [2 ,5 ]
Bedossa, Marc [2 ,3 ]
Toumoulin, Christine [2 ,4 ,5 ]
机构
[1] South East Univ, LIST, Nanjing 210096, Peoples R China
[2] Univ Rennes 1, Lab Traitment Signal Image, F-35000 Rennes, France
[3] CHU Rennes, Dept Cardiol Interventionelle, F-35033 Rennes, France
[4] Ctr Recherche Informat Biomed Sino Francais, F-35033 Rennes, France
[5] Natl Inst Hlth & Med Res INSERM, F-35000 Rennes, France
关键词
X-RAY ANGIOGRAPHY;
D O I
10.1109/IEMBS.2010.5627449
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A method is proposed for 3-D reconstruction of coronary from a limited number of projections in rotational angiography. A Bayesian maximum a posteriori (MAP) estimation is applied with a Poisson distributed projection to reconstruct the 3D coronary tree at a given instant of the cardiac cycle. Several regularizers are investigated L0-norm, L1 and L2-norm in order to take into account the sparsity of the data. Evaluations are reported on simulated data obtained from a 3D dynamic sequence acquired on a 64-slice GE LightSpeed CT scan. A performance study is conducted to evaluate the quality of the reconstruction of the structures.
引用
收藏
页码:3614 / 3617
页数:4
相关论文
共 50 条
  • [31] 3-D tomographic reconstruction of the average propagator from MRI data
    Pickalov, Valery
    Basser, Peter J.
    2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 710 - +
  • [32] TOMOGRAPHIC AND PROJECTIVE RECONSTRUCTION OF 3-D IMAGE DETAIL IN INVERSE SCATTERING
    FARHAT, NH
    CHU, TH
    WERNER, CL
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1984, 422 : 82 - 88
  • [33] FPGA Acceleration for 3-D Low-Dose Tomographic Reconstruction
    Zhang, Wentai
    Qiao, Linjun
    Hsu, William
    Cui, Yong
    Jiang, Ming
    Luo, Guojie
    IEEE TRANSACTIONS ON COMPUTER-AIDED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 2021, 40 (04) : 666 - 679
  • [34] Tracking 3-D coronary artery motion with biplane angiography
    Zhu, H
    Friedman, MH
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 605 - 608
  • [35] An Automatic 3-D Reconstruction of Coronary Arteries by Stereopsis
    Cetin, Mufit
    Iskurt, Ali
    JOURNAL OF MEDICAL SYSTEMS, 2016, 40 (04) : 1 - 11
  • [36] An Automatic 3-D Reconstruction of Coronary Arteries by Stereopsis
    Mufit Cetin
    Ali Iskurt
    Journal of Medical Systems, 2016, 40
  • [37] Evaluation of non-ECG and ECG-gated computed tomographic angiography for three-dimensional printing of anomalous coronary arteries in dogs with pulmonic stenosis
    Stieger-Vanegas, S. M.
    Scollan, K. F.
    Riebold, T. W.
    JOURNAL OF VETERINARY CARDIOLOGY, 2019, 26 : 39 - 50
  • [38] COMPARISON OF CONTRAST-ENHANCED TOMOGRAPHIC 3-D ULTRASOUND AGAINST ROTATIONAL ANGIOGRAPHY IMAGING IMMEDIATELY AFTER ENDOVASCULAR ANEURYSM REPAIR
    Rogers, Steven
    Lowe, Christopher
    Carreira, Joao
    Mccollum, Charles
    Ghosh, Jonathan
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (09): : 2356 - 2362
  • [39] Geometrically correct 3-D reconstruction of tortuous coronary arteries: Fusion of biplane coronary angiography and intravascular ultrasound pullback imaging
    Prause, G
    DeJong, SC
    McKay, CR
    Sonka, M
    CIRCULATION, 1996, 94 (08) : 1492 - 1492
  • [40] EVALUATION OF COARCTATION REPAIR WITH GATED MR ANGIOGRAPHY AND 3D RECONSTRUCTION
    BANK, ER
    PARKS, WJ
    SHEPPARD, SK
    PETTIGREW, RI
    RADIOLOGY, 1992, 185 : 308 - 308