Comparison of quantitative 3D magnetic resonance cholangiography measurements obtained using three different image acquisition methods

被引:1
|
作者
Mahalingam, Neeraja [1 ]
Ralli, George P. [2 ]
Trout, Andrew T. [3 ,4 ,5 ]
Dillman, Jonathan R. [1 ,3 ,4 ]
机构
[1] Cincinnati Childrens Hosp Med Ctr, Dept Radiol, Imaging Res Ctr, 250 Albert Sabin Way, Cincinnati, OH 45229 USA
[2] Perspectum Ltd, Oxford, England
[3] Cincinnati Childrens Hosp Med Ctr, Dept Radiol, Cincinnati, OH 45229 USA
[4] Univ Cincinnati, Coll Med, Dept Radiol, Cincinnati, OH USA
[5] Univ Cincinnati, Coll Med, Dept Pediat, Cincinnati, OH USA
关键词
3D magnetic resonance cholangiopancreatography; Biliary tree; Compressed sensing; Gradient and spin-echo; Quantitative imaging; SPIN-ECHO; MR CHOLANGIOPANCREATOGRAPHY; GRADIENT-ECHO; BREATH-HOLD; QUALITY; RECONSTRUCTION; FEASIBILITY;
D O I
10.1007/s00261-021-03330-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To compare quantitative biliary measurements obtained with three different magnetic resonance cholangiopancreatography (MRCP) acquisition methods. Methods This retrospective study was IRB-approved. Patients with combinations of clinically indicated 3D FSE MRCP with sensitivity encoding (SENSE), 3D FSE SENSE MRCP with compressed sensing (CS-FSE; acceleration factor 8), and 3D gradient and spin-echo (GRASE) MRCP, acquired between October 2018 and March 2020, were included. The MRCP + Tuning Threshold algorithm (Perspectum Ltd., Oxford, UK) was used to segment 3D biliary models from MRCP data, with multiple metrics quantified from the models. Single measure, two-way, mixed-effects intra-class correlations, Bland-Altman analyses, and Wilcoxon signed-rank tests were used to compare quantitative measurements. Results From 160 MRCP datasets (25 3D FSE, 67 3D CS-FSE, 68 3D GRASE) in 69 patients, 48 datasets (7 [28%] 3D FSE, 14 [21%] 3D CS-FSE, 27 [40%] 3D GRASE) failed post-processing due to motion artifacts. The remaining 112 MRCP datasets (18 3D FSE, 53 3D CS-FSE, 41 3D GRASE) from 60 patients were included in the analysis. There was good to excellent agreement between 3D FSE and 3D CS-FSE MRCP for diameter of the left and right hepatic ducts, biliary volume, number and length of ducts, and total length of dilations (ICC: 0.83-0.93). The only metrics that exhibited good agreement between 3D FSE and 3D GRASE MRCP were biliary volume (ICC: 0.75) and total number of dilations (ICC: 0.77). Conclusion 3D CS-FSE MRCP produces comparable biliary diameter metrics and global duct quantification to 3D FSE MRCP at a significantly reduced acquisition time.
引用
收藏
页码:196 / 208
页数:13
相关论文
共 50 条
  • [41] Quantitative measurements of flow dynamics in 3D hoppers using MRI
    Mehdizad, Maral
    Fullard, Luke
    Galvosas, Petrik
    Holland, Daniel
    POWDER TECHNOLOGY, 2021, 392 : 69 - 80
  • [42] The development of a new image acquisition & analysis system for 3D surface measurements using Confocal Laser Scanning Microscopy
    Peng, Zhongxiao
    Tomovich, Steven
    FRONTIERS IN MATERIALS SCIENCE AND TECHNOLOGY, 2008, 32 : 173 - 179
  • [43] Registration Using Nanotube Stationary Tomosynthesis: Comparison of 3D/3D to 3D/2D Methods
    Frederick, B.
    Lalush, D.
    Chang, S.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [44] Anatomic right ventricular measurements with live 3D echocardiography and magnetic resonance imaging: A comparison study using a new 4D analysis method
    Niemann, Petra S.
    Pinho, Luiz
    Balbach, Thomas
    Galuschky, Christian
    Brankenhagen, Michael
    Woodward, William J.
    Imus, Randal L.
    Silberbach, Michael
    Broberg, Craig
    Sheehan, Florence H.
    Jerosch-Herold, Michael
    Sahn, David J.
    CIRCULATION, 2006, 114 (18) : 799 - 799
  • [45] Comparison of image quality of 3D ultrasound: motorized acquisition versus freehand navigated acquisition, a phantom study
    N. M. Bekedam
    L. H. E. Karssemakers
    M. J. A. van Alphen
    R. L. P. van Veen
    L. E. Smeele
    M. B. Karakullukcu
    International Journal of Computer Assisted Radiology and Surgery, 2023, 18 : 1649 - 1663
  • [46] Comparison of image quality of 3D ultrasound: motorized acquisition versus freehand navigated acquisition, a phantom study
    Bekedam, N. M.
    Karssemakers, L. H. E.
    van Alphen, M. J. A.
    van Veen, R. L. P.
    Smeele, L. E.
    Karakullukcu, M. B.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2023, 18 (09) : 1649 - 1663
  • [47] Measurements in traffic signal structure using 3D image correlation
    Roy, Sougata
    Park, Yeun Chul
    Sause, Richard
    Pessiki, Stephen P.
    Schmidt, Tim
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON HEALTH MONITORING OF STRUCTURE, MATERIALS AND ENVIRONMENT, VOLS 1 AND 2, 2007, : 100 - +
  • [48] Acquisition of 3D image representation in multimedia ambiance communication using 3D laser scanner and digital camera
    Kanamaru, T
    Yamada, F
    Ichikawa, T
    Naemura, T
    Aizawa, K
    Saito, T
    THREE-DIMENSIONAL IMAGE CAPTURE AND APPLICATIONS III, 2000, 3958 : 80 - 89
  • [49] Comparison of Three Methods for the Estimation of Pineal Gland Volume Using Magnetic Resonance Imaging
    Acer, Niyazi
    Ilica, Ahmet Turan
    Turgut, Ahmet Tuncay
    Ozcelik, Ozlem
    Yildirim, Birdal
    Turgut, Mehmet
    SCIENTIFIC WORLD JOURNAL, 2012,
  • [50] Study of the performance of different subpixel image correlation methods in 3D digital image correlation
    Hu, Zhenxing
    Xie, Huimin
    Lu, Jian
    Hua, Tao
    Zhu, Jianguo
    APPLIED OPTICS, 2010, 49 (21) : 4044 - 4051