Comparison of quantitative 3D magnetic resonance cholangiography measurements obtained using three different image acquisition methods

被引:1
|
作者
Mahalingam, Neeraja [1 ]
Ralli, George P. [2 ]
Trout, Andrew T. [3 ,4 ,5 ]
Dillman, Jonathan R. [1 ,3 ,4 ]
机构
[1] Cincinnati Childrens Hosp Med Ctr, Dept Radiol, Imaging Res Ctr, 250 Albert Sabin Way, Cincinnati, OH 45229 USA
[2] Perspectum Ltd, Oxford, England
[3] Cincinnati Childrens Hosp Med Ctr, Dept Radiol, Cincinnati, OH 45229 USA
[4] Univ Cincinnati, Coll Med, Dept Radiol, Cincinnati, OH USA
[5] Univ Cincinnati, Coll Med, Dept Pediat, Cincinnati, OH USA
关键词
3D magnetic resonance cholangiopancreatography; Biliary tree; Compressed sensing; Gradient and spin-echo; Quantitative imaging; SPIN-ECHO; MR CHOLANGIOPANCREATOGRAPHY; GRADIENT-ECHO; BREATH-HOLD; QUALITY; RECONSTRUCTION; FEASIBILITY;
D O I
10.1007/s00261-021-03330-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To compare quantitative biliary measurements obtained with three different magnetic resonance cholangiopancreatography (MRCP) acquisition methods. Methods This retrospective study was IRB-approved. Patients with combinations of clinically indicated 3D FSE MRCP with sensitivity encoding (SENSE), 3D FSE SENSE MRCP with compressed sensing (CS-FSE; acceleration factor 8), and 3D gradient and spin-echo (GRASE) MRCP, acquired between October 2018 and March 2020, were included. The MRCP + Tuning Threshold algorithm (Perspectum Ltd., Oxford, UK) was used to segment 3D biliary models from MRCP data, with multiple metrics quantified from the models. Single measure, two-way, mixed-effects intra-class correlations, Bland-Altman analyses, and Wilcoxon signed-rank tests were used to compare quantitative measurements. Results From 160 MRCP datasets (25 3D FSE, 67 3D CS-FSE, 68 3D GRASE) in 69 patients, 48 datasets (7 [28%] 3D FSE, 14 [21%] 3D CS-FSE, 27 [40%] 3D GRASE) failed post-processing due to motion artifacts. The remaining 112 MRCP datasets (18 3D FSE, 53 3D CS-FSE, 41 3D GRASE) from 60 patients were included in the analysis. There was good to excellent agreement between 3D FSE and 3D CS-FSE MRCP for diameter of the left and right hepatic ducts, biliary volume, number and length of ducts, and total length of dilations (ICC: 0.83-0.93). The only metrics that exhibited good agreement between 3D FSE and 3D GRASE MRCP were biliary volume (ICC: 0.75) and total number of dilations (ICC: 0.77). Conclusion 3D CS-FSE MRCP produces comparable biliary diameter metrics and global duct quantification to 3D FSE MRCP at a significantly reduced acquisition time.
引用
收藏
页码:196 / 208
页数:13
相关论文
共 50 条
  • [21] Fuzzy logic approach to 3D magnetic resonance image segmentation
    Hata, Y
    Kobashi, S
    Kamiura, N
    Ishikawa, M
    INFORMATION PROCESSING IN MEDICAL IMAGING, 1997, 1230 : 387 - 392
  • [22] 3D Imaging Technology for Human Body Size and Shape Analysis: Comparison of Three Different Acquisition Technologies
    Bourgeois, Brianna
    Latimer, Dustin
    Stannard, Casey R.
    Romeo, Laurel
    Li, Xin
    Shepherd, John
    Ng, Bennett K.
    Heymsfield, Steven B.
    FASEB JOURNAL, 2017, 31
  • [23] Computed Tomography versus Optical Scanning: A Comparison of Different Methods of 3D Data Acquisition for Tooth Replication
    Kulczyk, Tomasz
    Rychlik, Michal
    Lorkiewicz-Muszynska, Dorota
    Abreu-Glowacka, Monica
    Czajka-Jakubowska, Agata
    Przystanska, Agnieszka
    BIOMED RESEARCH INTERNATIONAL, 2019, 2019
  • [24] The measurement of tibial torsion by magnetic resonance imaging in children: the comparison of three different methods
    Basaran S.H.
    Ercin E.
    Bayrak A.
    Cumen H.
    Bilgili M.G.
    Inci E.
    Avkan M.C.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (8) : 1327 - 1332
  • [25] Comparison of 3D turbulence measurements using three staring wind lidars and a sonic anemometer
    Mann, Jakob
    Cariou, Jean-Pierre
    Courtney, Michael S.
    Parmentier, Remy
    Mikkelsen, Torben
    Wagner, Rozenn
    Lindelow, Petter
    Sjoholm, Mikael
    Enevoldsen, Karen
    METEOROLOGISCHE ZEITSCHRIFT, 2009, 18 (02) : 135 - 140
  • [26] Comparison of 3D turbulence measurements using three staring wind lidars and a sonic anemometer
    Mann, J.
    Cariou, J-P
    Courtney, M. S.
    Parmentier, R.
    Mikkelsen, T.
    Wagner, R.
    Lindelow, P.
    Sjoholm, M.
    Enevoldsen, K.
    14TH INTERNATIONAL SYMPOSIUM FOR THE ADVANCEMENT OF BOUNDARY LAYER REMOTE SENSING, 2008, 1
  • [27] Magnetic resonance angiography of the origins of the supraaortic arteries: Comparison of single and double volume acquisition 3D time of flight
    Carriero, A
    Magarelli, N
    Padovano, F
    Baratto, M
    Fossaceca, R
    Bonoma, L
    JOURNAL OF NEURORADIOLOGY, 1996, 23 (02) : 62 - 68
  • [28] Diagnostic accuracy of 3D magnetic resonance elastography for assessing histologic grade of hepatocellular carcinoma: comparison of three methods for positioning region of interest
    Weimin Liu
    Dailin Rong
    Jie Zhu
    Yuanqiang Xiao
    Linqi Zhang
    Ying Deng
    Jun Chen
    Meng Yin
    Sudhakar K. Venkatesh
    Richard L. Ehman
    Jin Wang
    Abdominal Radiology, 2021, 46 : 4601 - 4609
  • [29] Diagnostic accuracy of 3D magnetic resonance elastography for assessing histologic grade of hepatocellular carcinoma: comparison of three methods for positioning region of interest
    Liu, Weimin
    Rong, Dailin
    Zhu, Jie
    Xiao, Yuanqiang
    Zhang, Linqi
    Deng, Ying
    Chen, Jun
    Yin, Meng
    Venkatesh, Sudhakar K.
    Ehman, Richard L.
    Wang, Jin
    ABDOMINAL RADIOLOGY, 2021, 46 (10) : 4601 - 4609
  • [30] Quantitative description of the 3D regional mechanics of the left atrium using cardiac magnetic resonance imaging
    Kuklik, P.
    Molaee, P.
    Podziemski, P.
    Ganesan, A. N.
    Brooks, A. G.
    Worthley, S. G.
    Sanders, P.
    PHYSIOLOGICAL MEASUREMENT, 2014, 35 (05) : 763 - 775