Nanomolar detection of hydrogen peroxide on glassy carbon electrode modified with electrodeposited cobalt oxide nanoparticles

被引:296
|
作者
Salimi, Abdollah
Hallaj, Rahman
Soltanian, Saied
Mamkhezri, Hussein
机构
[1] Univ Kurdistan, Dept Chem, Sanandaj, Iran
[2] Univ Kurdistan, Res Ctr Nanotechnol, Sanandaj, Iran
关键词
electrodeposition; cobalt oxide; nanoparticles; cyclic voltammetry; electrocatalysis; H2O2; oxidation; AMPEROMETRIC SENSOR; ELECTROCHEMICAL DEPOSITION; OXYGEN EVOLUTION; GLUCOSE-OXIDASE; THIN-FILMS; BIOSENSOR; OXIDATION; REDUCTION; COMPOSITE; GOLD;
D O I
10.1016/j.aca.2007.05.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical detection of H2O2 was investigated on a cobalt oxide nanoparticles modified glassy carbon electrode in phosphate buffer solution (pH 7). Cyclic voltammetry at potential range - 1.1 to 1.1 V from CoCl2 natural aqueous solution produced well defined cobalt oxide nanopaparticles deposited on the surface of glassy carbon electrode. The surface of resulting electrode was characterized with SEM. The formation of cobalt oxyhydroxide film was investigated by cyclic voltammetry in alkaline and natural aqueous solution. The modified electrode showed well defined and stable redox couples in both alkaline and natural aqueous solution. The modified electrode showed excellent electrocatalytic activity for oxidation of hydrogen peroxide. The response to H2O2 on the modified electrode was examined using cyclic voltammetry and amperometry. The amperometric detection of hydrogen peroxide is carried out at 0.75 V versus Ag/AgCl reference electrode in phosphate buffer solution with pH 7.4. The detection limit (S/N = 3) was 0.4 nM with linearity up to 6 orders of magnitude and sensitivity of 4.86 mu A mu M-1 cm(-2). The response time of the electrode to achieve 95% of the steady-state current is <2 s. No measurable reduction in analytical performance of the modified electrode was found by storing the electrode in ambient conditions for 20 days. This modified electrode recedes many advantages such as remarkable catalytic activity, good reproducibility, simple preparation procedure and long term stability of signal response during hydrogen peroxide oxidation. The immobilization of cobalt oxide nanoparticles on the surface of GC electrode appears to be a highly efficient method for the development of a new class of sensitive, stable and reproducible hydrogen peroxide electrochemical sensor. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:24 / 31
页数:8
相关论文
共 50 条
  • [31] Glassy carbon electrode modified with a graphene oxide/poly(o-phenylenediamine) composite for the chemical detection of hydrogen peroxide
    Van Hoa Nguyen
    Trung Hieu Tran
    Shim, Jae-Jin
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 44 : 144 - 150
  • [32] Electrochemical determination of glutathione based on an electrodeposited nickel oxide nanoparticles-modified glassy carbon electrode
    Yuan, Baiqing
    Zeng, Xiaoying
    Deng, Dehua
    Xu, Chunying
    Liu, Lin
    Zhang, Jiayu
    Gao, Yan
    Pang, Huan
    ANALYTICAL METHODS, 2013, 5 (07) : 1779 - 1783
  • [33] Dendrimer-rhodium nanoparticle modified glassy carbon electrode for amperometric detection of hydrogen peroxide
    Chandra, Sudeshna
    Lokesh, K. S.
    Nicolai, Anja
    Lang, Heinrich
    ANALYTICA CHIMICA ACTA, 2009, 632 (01) : 63 - 68
  • [34] Analytical sensing of hydrogen peroxide on Ag nanoparticles–multiwalled carbon nanotube-modified glassy carbon electrode
    Ahmadreza Afraz
    Amir Abbas Rafati
    Ali Hajian
    Journal of Solid State Electrochemistry, 2013, 17 : 2017 - 2025
  • [35] Development of Nonenzymatic Hydrogen Peroxide Sensor Based on Successive Pd-Ag Electrodeposited Nanoparticles on Glassy Carbon Electrode
    Roushani, Mahmoud
    Dizajdizi, Behruz Zare
    ELECTROANALYSIS, 2016, 28 (04) : 787 - 793
  • [36] Amperometric Detection of Isoprenaline Based on Glassy Carbon Electrode Modified by Iridium Oxide Nanoparticles
    Roushani, Mahmoud
    Farokhi, Somayeh
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2015, 26 (05) : 1034 - 1042
  • [37] A novel enzymatic glucose biosensor and sensitive non-enzymatic hydrogen peroxide sensor based on graphene and cobalt oxide nanoparticles composite modified glassy carbon electrode
    Karuppiah, Chelladurai
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    Veeramani, Vediyappan
    Periakaruppan, Prakash
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 196 : 450 - 456
  • [38] Studies on the Electrocatalytic Reduction of Hydrogen Peroxide on a Glassy Carbon Electrode Modified With a Ruthenium Oxide Hexacyanoferrate Film
    Pena, Roselyn C.
    Gamboa, Juan C. M.
    Bertotti, Mauro
    Paixao, Thiago R. L. C.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (02): : 394 - 403
  • [39] Sensitive warfarin sensor based on cobalt oxide nanoparticles electrodeposited at multi-walled carbon nanotubes modified glassy carbon electrode (CoxOyNPs/MWCNTs/GCE)
    Gholivand, Mohammad Bagher
    Solgi, Mohammad
    ELECTROCHIMICA ACTA, 2017, 246 : 689 - 698
  • [40] Amperometric Sensing of Hydrogen Peroxide Using Graphene Oxide-Alizarin Modified Glassy Carbon Electrode
    Muhammet, Sinan Mithat
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (06):