Thermal performance analysis of a solar air collection-cascade storage system integrated with micro-heat pipe arrays

被引:9
|
作者
Diao, Yanhua [1 ]
Qi, Naixin [1 ]
Wang, Zeyu [1 ]
Zhao, Yaohua [1 ]
Chen, Chuanqi [1 ]
Wang, Zhen [1 ]
机构
[1] Beijing Univ Technol, Beijing Key Lab Green Built Environm & Efficient, Beijing 100124, Peoples R China
关键词
Cascade storage; Solar air heating system; Micro-heat pipe array; Latent heat storage; Thermal performance analysis; PHASE-CHANGE-MATERIALS; ENERGY-STORAGE; EXERGY ANALYSIS; NUMERICAL-ANALYSIS; OPTIMIZATION; ENHANCEMENT; UNIT; PCMS; DRYER; CONFIGURATION;
D O I
10.1016/j.solener.2021.06.071
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This study aims to establish a novel solar air collection-cascade storage system. Flat-plate micro-heat pipe arrays are applied in collector and heat storage units for heat transfer enhancement. To increase energy utilization ratio and improve system stability, a cascade storage configuration using paraffin and lauric acid is adopted. In the charging process, the cascade heat storage units store the solar irradiance collected by the collector in the phase change materials through the heat exchange fluid (air). During the discharging process, air takes away the heat stored in the phase change material. The heat transfer process and thermal performance of the system was analyzed experimentally in different volume flow rates from the perspectives of energy and exergy. The experimental results show that the air flow rate affects the thermal performance of the system significantly: as the volume flow rate increases, the heat collection power and efficiency show an upward trend, and the heat storage power and heat storage efficiency also show an increasing trend. Contrary to the increasing trend of exergy storage efficiency, exergy extraction efficiency decreases with increasing volume flow rate. An airflow rate of 220 m(3)/h obtains the highest average heat collection power and average heat collection efficiency, which are 542.0 W and 35.8%, respectively. In this condition, the average heat storage power and average heat storage efficiency of latent heat storage unit I are 175.1 W and 67.5%, respectively, and those of unit II are 136.0 W and 87.5%, respectively.
引用
收藏
页码:1271 / 1290
页数:20
相关论文
共 50 条
  • [41] Experimental investigations of the performance of a solar air collector with latent heat thermal storage integrated with the solar absorber
    Charvat, P.
    Pech, O.
    Hejcik, J.
    EFM12 - EXPERIMENTAL FLUID MECHANICS 2012, 2013, 45
  • [42] Experimental investigation and performance evaluation of a vacuum tube solar air collector based on micro heat pipe arrays
    Zhu, Ting-ting
    Zhao, Yao-hua
    Diao, Yan-hua
    Li, Feng-fei
    Quan, Zhen-hua
    JOURNAL OF CLEANER PRODUCTION, 2017, 142 : 3517 - 3526
  • [43] Performance of an air-cooled photovoltaic/thermal system using micro heat pipe array
    Wang, Gang
    Yang, Yongqing
    Yu, Wan
    Wang, Tian
    Zhu, Tingting
    APPLIED THERMAL ENGINEERING, 2022, 217
  • [44] Performance analysis on solar heat storage type compressed air energy storage system
    Zhu, Rui
    Xu, Yujie
    Li, Bin
    Chen, Haisheng
    Guo, Huan
    Li, Yuping
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2019, 40 (06): : 1536 - 1544
  • [45] Analysis of the heat dissipation performance of U-shaped flat plate micro-heat pipe LED radiator
    Yu W.
    Han Y.
    Wang G.
    Su H.
    Hu T.
    Su L.
    Dong P.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2024, 40 (09): : 227 - 235
  • [46] Thermal analysis of a solar concentrating system integrated with sensible and latent heat storage
    Bhale, Purnanand V.
    Rathod, Manish K.
    Sahoo, Laxmikant
    CLEAN, EFFICIENT AND AFFORDABLE ENERGY FOR A SUSTAINABLE FUTURE, 2015, 75 : 2157 - 2162
  • [47] A novel thermal storage integrated evacuated tube heat pipe solar air heater: Energy, exergy, economic and environmental impact analysis
    Mathew, Adarsh Abi
    Thangavel, Venugopal
    SOLAR ENERGY, 2021, 220 : 828 - 842
  • [48] A novel thermal storage integrated evacuated tube heat pipe solar air heater: Energy, exergy, economic and environmental impact analysis
    Abi Mathew, Adarsh
    Thangavel, Venugopal
    Solar Energy, 2021, 220 : 828 - 842
  • [49] Performance analysis of adiabatic compressed air heat storage and solar hybrid system
    Liu, Wenyi
    Man, Xiaozeng
    Xie, Angjun
    Niu, Chenwei
    Xu, Gang
    Li, Qing
    ECOS 2016 - Proceedings of the 29th International Conference on Efficiency, Cost, Optimisation, Simulation and Environmental Impact of Energy Systems, 2016,
  • [50] Numerical analysis of heat transfer characteristics for air in a latent heat thermal energy storage using flat miniature heat pipe arrays
    Diao, Y. H.
    Yin, L. L.
    Wang, Z. Y.
    Zhao, Y. H.
    Liang, L.
    Bai, F. W.
    APPLIED THERMAL ENGINEERING, 2019, 162