Thermal performance analysis of a solar air collection-cascade storage system integrated with micro-heat pipe arrays

被引:9
|
作者
Diao, Yanhua [1 ]
Qi, Naixin [1 ]
Wang, Zeyu [1 ]
Zhao, Yaohua [1 ]
Chen, Chuanqi [1 ]
Wang, Zhen [1 ]
机构
[1] Beijing Univ Technol, Beijing Key Lab Green Built Environm & Efficient, Beijing 100124, Peoples R China
关键词
Cascade storage; Solar air heating system; Micro-heat pipe array; Latent heat storage; Thermal performance analysis; PHASE-CHANGE-MATERIALS; ENERGY-STORAGE; EXERGY ANALYSIS; NUMERICAL-ANALYSIS; OPTIMIZATION; ENHANCEMENT; UNIT; PCMS; DRYER; CONFIGURATION;
D O I
10.1016/j.solener.2021.06.071
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This study aims to establish a novel solar air collection-cascade storage system. Flat-plate micro-heat pipe arrays are applied in collector and heat storage units for heat transfer enhancement. To increase energy utilization ratio and improve system stability, a cascade storage configuration using paraffin and lauric acid is adopted. In the charging process, the cascade heat storage units store the solar irradiance collected by the collector in the phase change materials through the heat exchange fluid (air). During the discharging process, air takes away the heat stored in the phase change material. The heat transfer process and thermal performance of the system was analyzed experimentally in different volume flow rates from the perspectives of energy and exergy. The experimental results show that the air flow rate affects the thermal performance of the system significantly: as the volume flow rate increases, the heat collection power and efficiency show an upward trend, and the heat storage power and heat storage efficiency also show an increasing trend. Contrary to the increasing trend of exergy storage efficiency, exergy extraction efficiency decreases with increasing volume flow rate. An airflow rate of 220 m(3)/h obtains the highest average heat collection power and average heat collection efficiency, which are 542.0 W and 35.8%, respectively. In this condition, the average heat storage power and average heat storage efficiency of latent heat storage unit I are 175.1 W and 67.5%, respectively, and those of unit II are 136.0 W and 87.5%, respectively.
引用
收藏
页码:1271 / 1290
页数:20
相关论文
共 50 条
  • [21] Numerical investigation of the thermal performance enhancement of latent heat thermal energy storage using longitudinal rectangular fins and flat micro-heat pipe arrays
    Diao, Y. H.
    Liang, L.
    Zhao, Y. H.
    Wang, Z. Y.
    Bai, F. W.
    APPLIED ENERGY, 2019, 233 : 894 - 905
  • [22] Experimental study of the thermal characteristics of a heat storage wall with micro-heat pipe array (MHPA) and PCM in solar greenhouse
    Guan, Yong
    Meng, Qi
    Ji, Tianxu
    Hu, Wanling
    Li, Wenlong
    Liu, Tianming
    ENERGY, 2023, 264
  • [23] Analysis of micro heat pipe array based evacuated tube solar water heater integrated with an energy storage system for improved thermal performance
    Tamuli, Bhaskar Ranjan
    Nath, Sujit
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 41
  • [24] Experimental study on the thermal performance of a new type of thermal energy storage based on flat micro-heat pipe array
    Li, Feng-fei
    Diao, Yan-hua
    Zhao, Yao-hua
    Zhu, Ting-ting
    Liu, Jing
    ENERGY CONVERSION AND MANAGEMENT, 2016, 112 : 395 - 403
  • [25] Performance optimization of ice thermal storage device based on micro heat pipe arrays
    Liu, Zichu
    Quan, Zhenhua
    Zhao, Yaohua
    Jing, Heran
    Yang, Mingguang
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2022, 134
  • [26] Thermal performance of the flat micro-heat pipe with the wettability gradient surface by laser fabrication
    Xie, Xiaozhu
    Weng, Qing
    Luo, Zhiqiang
    Long, Jiangyou
    Wei, Xin
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 125 : 658 - 669
  • [27] Experimental study on the new type of electrical storage heater based on flat micro-heat pipe arrays
    WANG ZeYu
    DIAO YanHua
    ZHAO YaoHua
    LIANG Lin
    WANG TengYue
    Science China(Technological Sciences), 2018, (02) : 219 - 231
  • [28] Experimental study on the new type of electrical storage heater based on flat micro-heat pipe arrays
    WANG ZeYu
    DIAO YanHua
    ZHAO YaoHua
    LIANG Lin
    WANG TengYue
    Science China(Technological Sciences), 2018, 61 (02) : 219 - 231
  • [29] Experimental study on the new type of electrical storage heater based on flat micro-heat pipe arrays
    ZeYu Wang
    YanHua Diao
    YaoHua Zhao
    Lin Liang
    TengYue Wang
    Science China Technological Sciences, 2018, 61 : 219 - 231
  • [30] Experimental study on the thermal performance of micro-heat pipe with cross-section of polygon
    Moon, SH
    Hwang, G
    Ko, SC
    Kim, YT
    MICROELECTRONICS RELIABILITY, 2004, 44 (02) : 315 - 321