Evaluation of an in-shoe pressure measurement system in horses

被引:19
|
作者
Judy, CE [1 ]
Galuppo, LD
Snyder, JR
Willits, NH
机构
[1] Vet Med Teaching Hosp, Davis, CA 95616 USA
[2] Univ Calif Davis, Dept Surg & Radiol Sci, Davis, CA 95616 USA
[3] Univ Calif Davis, Sch Vet Med, Davis, CA 95616 USA
[4] Univ Calif Davis, Div Stat, Davis, CA 95616 USA
[5] Univ Calif Davis, Coll Letters & Sci, Davis, CA 95616 USA
关键词
D O I
10.2460/ajvr.2001.62.23
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To develop an objective, accurate method for quantifying forelimb ground reaction forces in horses by adapting a human in-shoe pressure measurement system and determine the reliability of the system for shed and unshod horses. Animals-6 adult Thoroughbreds. Procedure-Horses were instrumented with a human in-shoe pressure measurement system and evaluated at a trot (3 m/s) on a motorized treadmill. Maximum force, stance time, and peak contact area were evaluated for shed and unshod horses. Three trials were performed for shed and unshod horses, and differences in the measured values were examined with a mixed model ANOVA for repeated measures. Sensor accuracy was evaluated by correlating measured variables to clinically observed lameness and by a variance component analysis. Results-4 of 6 horses were determined to be lame in a forelimb on the basis of clinical examination and measured values from the system. No significant differences were observed between shed and unshod horses for maximum force and stance time. A significant decrease in peak contact area was observed for shed and unshod horses at each successive trial. Maximum force measurements provided the highest correlation for detecting lameness (r = 0.91, shed horses; r = 1.0, unshod horses). A variance component analysis revealed that 3 trials provided a variance of 35.35 kg for maximum force (+/- 5.78% accuracy), 0.007 seconds for stance time (+/- 2.5% accuracy), and 8.58 cm(2) for peak contact area (+/- 11.95% accuracy). Conclusions and Clinical Relevance-The in-shoe pressure measurement system provides an accurate, objective, and effective method to evaluate lameness in horses.
引用
收藏
页码:23 / 28
页数:6
相关论文
共 50 条
  • [41] Evaluation of in-shoe plantar pressure and shear during walking for diabetic foot ulcer prevention
    Tang, Jinghua
    Bader, Dan L.
    Parker, Daniel J.
    Forghany, Saeed
    Nester, Christopher J.
    Moser, David
    Jiang, Liudi
    JOURNAL OF WOUND CARE, 2023, 32 (09) : 587 - 596
  • [42] In-Shoe Pressure Measurement and Foot Orthosis Research A Giant Leap Forward or a Step Too Far?
    Spooner, Simon K.
    Smith, David K.
    Kirby, Kevin A.
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2010, 100 (06) : 518 - 529
  • [43] Establishment of a measurement method for in-shoe pressure and shear stress in specific regions for diabetic ulcer prevention
    Amemiya, Ayumi
    Noguchi, Hiroshi
    Oe, Makoto
    Sanada, Hiromi
    Mori, Taketoshi
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 2291 - 2294
  • [44] Development of a quantitative in-shoe measurement system for assessing balance: Sixteen-sensor insoles
    Bamberg, Stacy J. Morris
    LaStayo, Paul
    Dibble, Lee
    Musselman, Josh
    Raghavendra, Swarna Kiran Dasa
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 5774 - +
  • [45] IN-SHOE PRESSURE DISTRIBUTION FOR RUNNING IN VARIOUS TYPES OF FOOTWEAR
    HENNIG, EM
    MILANI, TL
    JOURNAL OF APPLIED BIOMECHANICS, 1995, 11 (03) : 299 - 310
  • [46] A Multiplexer System for Multi-Channel Charge Signal Processing in In-Shoe Force Measurement
    Geng, Zhiguang
    Pepper, Matthew G.
    Yan, Yong
    2011 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2011, : 74 - 78
  • [47] The effect of shoe lacing on plantar pressure distribution and in-shoe displacement of the foot in healthy participants
    Fiedler, Karin Elisabeth
    Stuijfzand, Wijnand Jan A.
    Harlaar, Jaap
    Dekker, Joost
    Beckerman, Heleen
    GAIT & POSTURE, 2011, 33 (03) : 396 - 400
  • [48] Development of an in-shoe pressure-sensitive device for gait analysis
    De Rossi, S. M. M.
    Lenzi, T.
    Vitiello, N.
    Donati, M.
    Persichetti, A.
    Giovacchini, F.
    Vecchi, F.
    Carrozza, M. C.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 5637 - 5640
  • [49] Clinical uses of in-shoe pressure analysis in podiatric sports medicine
    Williams, Bruce E.
    Yakel, James D.
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2007, 97 (01) : 49 - 58
  • [50] Leg Length Discrepancy: A Study on In-Shoe Plantar Pressure Distribution
    Abu-Faraj, Ziad O.
    Abdul-Al, Mohamed M.
    Al-Deeb, Raghad A.
    2015 8TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI), 2015, : 381 - 385