Evaluation of an in-shoe pressure measurement system in horses

被引:19
|
作者
Judy, CE [1 ]
Galuppo, LD
Snyder, JR
Willits, NH
机构
[1] Vet Med Teaching Hosp, Davis, CA 95616 USA
[2] Univ Calif Davis, Dept Surg & Radiol Sci, Davis, CA 95616 USA
[3] Univ Calif Davis, Sch Vet Med, Davis, CA 95616 USA
[4] Univ Calif Davis, Div Stat, Davis, CA 95616 USA
[5] Univ Calif Davis, Coll Letters & Sci, Davis, CA 95616 USA
关键词
D O I
10.2460/ajvr.2001.62.23
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To develop an objective, accurate method for quantifying forelimb ground reaction forces in horses by adapting a human in-shoe pressure measurement system and determine the reliability of the system for shed and unshod horses. Animals-6 adult Thoroughbreds. Procedure-Horses were instrumented with a human in-shoe pressure measurement system and evaluated at a trot (3 m/s) on a motorized treadmill. Maximum force, stance time, and peak contact area were evaluated for shed and unshod horses. Three trials were performed for shed and unshod horses, and differences in the measured values were examined with a mixed model ANOVA for repeated measures. Sensor accuracy was evaluated by correlating measured variables to clinically observed lameness and by a variance component analysis. Results-4 of 6 horses were determined to be lame in a forelimb on the basis of clinical examination and measured values from the system. No significant differences were observed between shed and unshod horses for maximum force and stance time. A significant decrease in peak contact area was observed for shed and unshod horses at each successive trial. Maximum force measurements provided the highest correlation for detecting lameness (r = 0.91, shed horses; r = 1.0, unshod horses). A variance component analysis revealed that 3 trials provided a variance of 35.35 kg for maximum force (+/- 5.78% accuracy), 0.007 seconds for stance time (+/- 2.5% accuracy), and 8.58 cm(2) for peak contact area (+/- 11.95% accuracy). Conclusions and Clinical Relevance-The in-shoe pressure measurement system provides an accurate, objective, and effective method to evaluate lameness in horses.
引用
收藏
页码:23 / 28
页数:6
相关论文
共 50 条
  • [21] Observations on the F-Scan in-shoe pressure measuring system
    Woodburn, J
    Helliwell, PS
    CLINICAL BIOMECHANICS, 1996, 11 (05) : 301 - 304
  • [22] Wireless In-shoe Force System
    Lawrence, TL
    Schmidt, RN
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 2238 - 2241
  • [23] Effect of shoe modifications on center of pressure and in-shoe plantar pressures
    Xu, H
    Akai, M
    Kakurai, S
    Yokota, K
    Kaneko, H
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 1999, 78 (06) : 516 - 524
  • [24] Effect of shoe modifications on center of pressure and in-shoe plantar pressures
    Xu, Hong
    Akai, Masami
    Kakurai, Shuichi
    Yokota, Kazuhiko
    Kaneko, Hideo
    American Journal of Physical Medicine and Rehabilitation, 78 (06): : 516 - 524
  • [25] Reliability of the Pedar in-shoe system for plantar pressure measurement in diabetic patients with and without neuropathy: a prospective study
    Forogh, Bijan
    Raissi, Gholam Reza
    Soleymanzadeh, Hosnieh
    Cham, Masumeh Bagherzadeh
    CURRENT ORTHOPAEDIC PRACTICE, 2022, 33 (01): : 56 - 61
  • [26] METHOD FOR IN-SHOE SHEAR-STRESS MEASUREMENT
    LORD, M
    HOSEIN, R
    WILLIAMS, RB
    JOURNAL OF BIOMEDICAL ENGINEERING, 1992, 14 (03): : 181 - 186
  • [27] Comparison of an in-shoe pressure measurement device to a force plate: concurrent validity of center of pressure measurements
    Chesnin, KJ
    Selby-Silverstein, L
    Besser, MP
    GAIT & POSTURE, 2000, 12 (02) : 128 - 133
  • [28] Wearing the F-Scan mobile in-shoe pressure measurement system alters gait characteristics during running
    Kong, Pui W.
    De Heer, Hendrik
    GAIT & POSTURE, 2009, 29 (01) : 143 - 145
  • [29] In-shoe pressure measurements with a viscoelastic heel orthosis
    Hsi, WL
    Lai, JS
    Yang, PY
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1999, 80 (07): : 805 - 810
  • [30] In-shoe multisensory data acquisition system
    Morley, RE
    Richter, EJ
    Klaesner, JW
    Maluf, KS
    Mueller, MJ
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (07) : 815 - 820