Evaluation of an in-shoe pressure measurement system in horses

被引:19
|
作者
Judy, CE [1 ]
Galuppo, LD
Snyder, JR
Willits, NH
机构
[1] Vet Med Teaching Hosp, Davis, CA 95616 USA
[2] Univ Calif Davis, Dept Surg & Radiol Sci, Davis, CA 95616 USA
[3] Univ Calif Davis, Sch Vet Med, Davis, CA 95616 USA
[4] Univ Calif Davis, Div Stat, Davis, CA 95616 USA
[5] Univ Calif Davis, Coll Letters & Sci, Davis, CA 95616 USA
关键词
D O I
10.2460/ajvr.2001.62.23
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To develop an objective, accurate method for quantifying forelimb ground reaction forces in horses by adapting a human in-shoe pressure measurement system and determine the reliability of the system for shed and unshod horses. Animals-6 adult Thoroughbreds. Procedure-Horses were instrumented with a human in-shoe pressure measurement system and evaluated at a trot (3 m/s) on a motorized treadmill. Maximum force, stance time, and peak contact area were evaluated for shed and unshod horses. Three trials were performed for shed and unshod horses, and differences in the measured values were examined with a mixed model ANOVA for repeated measures. Sensor accuracy was evaluated by correlating measured variables to clinically observed lameness and by a variance component analysis. Results-4 of 6 horses were determined to be lame in a forelimb on the basis of clinical examination and measured values from the system. No significant differences were observed between shed and unshod horses for maximum force and stance time. A significant decrease in peak contact area was observed for shed and unshod horses at each successive trial. Maximum force measurements provided the highest correlation for detecting lameness (r = 0.91, shed horses; r = 1.0, unshod horses). A variance component analysis revealed that 3 trials provided a variance of 35.35 kg for maximum force (+/- 5.78% accuracy), 0.007 seconds for stance time (+/- 2.5% accuracy), and 8.58 cm(2) for peak contact area (+/- 11.95% accuracy). Conclusions and Clinical Relevance-The in-shoe pressure measurement system provides an accurate, objective, and effective method to evaluate lameness in horses.
引用
收藏
页码:23 / 28
页数:6
相关论文
共 50 条
  • [1] Validity and reliability of the XSENSOR in-shoe pressure measurement system
    Parker, Daniel
    Andrews, Jennifer
    Price, Carina
    PLOS ONE, 2023, 18 (01):
  • [2] Reliability of an in-shoe pressure measurement system during treadmill walking
    Kernozek, TW
    LaMott, EE
    Dancisak, MJ
    FOOT & ANKLE INTERNATIONAL, 1996, 17 (04) : 204 - 209
  • [3] IN-SHOE FOOT PRESSURE MEASUREMENT SYSTEM UTILIZING PIEZOELECTRIC FILM TRANSDUCERS
    NEVILL, AJ
    PEPPER, MG
    WHITING, M
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1995, 33 (01) : 76 - 81
  • [4] In-Shoe Plantar Pressure Measurement and Analysis System Based on Fabric Pressure Sensing Array
    Shu, Lin
    Hua, Tao
    Wang, Yangyong
    Li, Qiao
    Feng, David Dagan
    Tao, Xiaoming
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2010, 14 (03): : 767 - 775
  • [5] Evaluation of Two Approaches for Aligning Data Obtained from a Motion Capture System and an In-Shoe Pressure Measurement System
    Kim, Sunwook
    Nussbaum, Maury A.
    SENSORS, 2014, 14 (09) : 16994 - 17007
  • [6] Accuracy and precision of two in-shoe pressure measurement systems
    Hsiao, HW
    Guan, JH
    Weatherly, M
    ERGONOMICS, 2002, 45 (08) : 537 - 555
  • [7] IN-SHOE PLANTAR MEASUREMENT WITH TEKSCAN SENSOR SYSTEM
    KOCH, M
    BIOMEDIZINISCHE TECHNIK, 1993, 38 (10): : 243 - 248
  • [8] Validity and repeatability of three in-shoe pressure measurement systems
    Price, Carina
    Parker, Daniel
    Nester, Christopher
    GAIT & POSTURE, 2016, 46 : 69 - 74
  • [9] USE OF AN IN-SHOE PRESSURE MEASUREMENT SYSTEM IN THE MANAGEMENT OF PATIENTS WITH NEUROPATHIC ULCERS OR METATARSALGIA
    MUELLER, MJ
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1995, 21 (06): : 328 - 336
  • [10] The accuracy and precision of an equine in-shoe pressure measurement system as a tool for gait analysis
    Perino, V. V.
    Kawcak, C. E.
    Frisbie, D. D.
    Reiser, R. F.
    Mcllwraith, C. W.
    JOURNAL OF EQUINE VETERINARY SCIENCE, 2007, 27 (04) : 161 - 166