Determination of left ventricular volume, ejection fraction, and myocardial mass by real-time three-dimensional echocardiography

被引:16
|
作者
Qin, JX [1 ]
Shiota, T [1 ]
Thomas, JD [1 ]
机构
[1] Cleveland Clin Fdn, Dept Cardiol, Cleveland, OH 44195 USA
关键词
echocardiography; ventricular function;
D O I
10.1111/j.1540-8175.2000.tb01237.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Reconstructed three-dimensional (3-D) echocardiography is an accurate and reproducible method of assessing left ventricular (LV) functions. However, it has limitations for clinical study due to the requirement of complex: computer and echocardiographic analysis systems, electrocardiograph icl respiratory gating, and prolonged imaging times. Real-time 3-D echocardiography has a major advantage of conveniently visualizing the entire cardiac anatomy in three dimensions and of potentially accurately quantifying LV volumes, ejection fractions, and myocardial mass in patients even in the presence of an LV aneurysm. Although the image quality of the current real-time 3-D echocardiographic methods is not optimal, its widespread clinical application is possible because of the convenient and fast image acquisition. We review real-time 3-D echocardiographic image acquisition and quantitative analysis for the evaluation of LV function and LV mass.
引用
收藏
页码:781 / 786
页数:6
相关论文
共 50 条
  • [21] In vitro validation of right ventricular volume and mass measurement by real-time three-dimensional echocardiography
    Chen, GZ
    Sun, K
    Huang, GY
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2006, 23 (05): : 395 - 399
  • [22] Real-time three-dimensional echocardiography for in-vitro assessment of left ventricular mass in dogs
    Takuma, S
    Cabreriza, SE
    Zwas, DR
    Sciacca, R
    Fard, A
    Chaudhry, H
    Di Tullio, MR
    Spotnitz, H
    Homma, S
    CIRCULATION, 1998, 98 (17) : 701 - 701
  • [23] Accuracy and reproducibility of real-time three-dimensional echocardiography for assessment of right ventricular volumes and ejection fraction in children
    Lu, Xiuzhang
    Nadvoretskiy, Vyacheslav
    Bu, Liping
    Stolpen, Alan
    Ayres, Nancy
    Pignatelli, Ricardo H.
    Kovalchin, John P.
    Grenier, Michelle
    Klas, Berthold
    Ge, Shuping
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (01) : 84 - 89
  • [24] Real time three-dimensional echocardiography: Measurement of left ventricular mass in dogs
    Fleishman, CE
    Ota, T
    Ohazama, CJ
    Stetten, G
    Lewis, CW
    Li, J
    vonRamm, OT
    Kisslo, J
    CIRCULATION, 1996, 94 (08) : 4019 - 4019
  • [25] DETERMINATION OF LEFT-VENTRICULAR EJECTION FRACTION BY VISUAL ESTIMATION DURING REAL-TIME TWO-DIMENSIONAL ECHOCARDIOGRAPHY
    RICH, S
    SHEIKH, A
    GALLASTEGUI, J
    KONDOS, GT
    MASON, T
    LAM, W
    AMERICAN HEART JOURNAL, 1982, 104 (03) : 603 - 606
  • [27] Estimation of the right ventricular volume and ejection fraction by transthoracic three-dimensional echocardiography
    Shinichi Fujimoto
    Reiko Mizuno
    Yoshihito Nakagawa
    Kazuhiro Dohi
    Hiroshi Nakano
    The International Journal of Cardiac Imaging, 1998, 14 : 385 - 390
  • [28] Accuracy and Reproducibility of Real-Time Three-Dimensional Echocardiography Versus Two-Dimensional Echocardiography in Measuring Left Ventricular Volumes and Ejection Fraction in Daily Clinical Practice
    Oon, Y. Y.
    Amin, N. H. Mohd
    Said, A.
    Kilung, A.
    Koh, K. T.
    Khaw, C. S.
    Ho, K. H.
    Shu, F.
    Tan, C. T.
    Voon, C. Y.
    Khiew, N. Z.
    Cham, Y. L.
    Alan, F.
    Ong, T. K.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 249 : S18 - S19
  • [29] Effects of Age and Gender on Left Atrial Ejection Force and Volume from Real-Time Three-Dimensional Echocardiography
    Zhong, Liang
    Tan, Lay Kheng
    Finn, Chris J.
    Ghista, Dhanjoo
    Liew, Reginald
    Ding, Zee Pin
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2012, 41 (04) : 161 - 169
  • [30] Accuracy of measurement of left ventricular volume and election fraction by now real-time three-dimensional echocardiography in patients with wall motion abnormalities secondary to myocardial infarction
    Arai, K
    Hozumi, T
    Matsumura, Y
    Sugioka, K
    Takemoto, Y
    Yamagishi, H
    Yoshiyama, M
    Kasanuki, H
    Yoshikawa, J
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (05): : 552 - 558