Effects of Age and Gender on Left Atrial Ejection Force and Volume from Real-Time Three-Dimensional Echocardiography

被引:0
|
作者
Zhong, Liang [1 ]
Tan, Lay Kheng [1 ]
Finn, Chris J. [2 ]
Ghista, Dhanjoo [3 ]
Liew, Reginald [4 ]
Ding, Zee Pin [4 ]
机构
[1] Natl Heart Ctr Singapore, Cardiac Mech Engn & Physiol Unit, Singapore 168752, Singapore
[2] Sir Charles Gairdiner Hosp Perth, Perth, WA, Australia
[3] Framingham State Univ, Framingham, MA USA
[4] Natl Heart Ctr Singapore, Dept Cardiol, Singapore 168752, Singapore
基金
英国医学研究理事会;
关键词
Age; LA Ejection Force; RT3DE; Volume; 2-DIMENSIONAL ECHOCARDIOGRAPHY; HEART-FAILURE; RECOMMENDATIONS; GEOMETRY; SIZE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: This study was carried out to (i) provide the methodology for determining left atrial (LA) volume, emptying fraction and ejection force (LAEF), from real-time 3-dimensional echocardiography (RT3DE), and (ii) evaluate the effects of age and gender on LA volume and LAEF in a wide age range of healthy participants. Materials and Methods: RT3DE was performed in 102 healthy participants (age range, 20 to 80 years). From full-volume data sets, LA endocardial borders were automatically traced and LA volumes were determined. LAEF was calculated as 1/3xmitral annular area x (blood density) x (peak velocity of A wave)2 according to Newton's law of motion and hydrodynamics; wherein the mitral annular area (MVA) is traced using RT3DE and A is the peak Doppler-derived blood velocity at atrial systole with the sample volume placed at the mitral annulus level. Results: ANOVA analysis revealed that LA volume indices were significantly correlated with age (r = 0.366, P <0.0001 for maximal volume index and r = 0.288, P <0.005 for minimal volume index). LAEF was also significantly positively correlated with age (r = 0.49, P<0.0001). The LA emptying fraction was maintained across ages. LA volume indices and LAEF did not differ significantly with gender. Conclusion: Our data can be used as normal reference values for LA volumes and LAEF. We have demonstrated that age is positively related to LA volume indices and LAEF, which suggests that age-dependent cut-off values should be considered in those with heart disease.
引用
收藏
页码:161 / 169
页数:9
相关论文
共 50 条
  • [1] Evaluation of Left Atrial Volumes and Ejection Force by Real-Time Three-Dimensional Echocardiography
    Nemes, Attila
    Forster, Tamas
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2012, 41 (09) : 425 - 425
  • [2] Re: Evaluation of Left Atrial Volumes and Ejection Force by Real-Time Three-Dimensional Echocardiography
    Zhong, Liang
    Liew, Reginald
    Ding, Zee Pin
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2012, 41 (09) : 426 - 426
  • [3] Assessment of left atrial ejection force in hypertrophic cardiomyopathy using real-time three-dimensional echocardiography
    Anwar, Ashraf M.
    Soliman, Osama I. I.
    Geleijnse, Marcel L.
    Michels, Michelle
    Vletter, Wim B.
    Nemes, Attila
    ten Cate, Folkert J.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (06) : 744 - 748
  • [4] Assessment of left atrial volume and function by real-time three-dimensional echocardiography
    Anwar, Ashraf M.
    Soliman, Osama I. I.
    Geleijnse, Marcel L.
    Nemes, Attila
    Vletter, Wim B.
    ten Cate, Folkert J.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 123 (02) : 155 - 161
  • [5] Left ventricular ejection fraction by real-time three-dimensional echocardiography
    van Dalen, B. M.
    NETHERLANDS HEART JOURNAL, 2014, 22 (09) : 380 - 382
  • [6] Left atrial minimum volume by real-time three-dimensional echocardiography as an indicator of diastolic dysfunction
    Lin Qiong-wen
    Wang Wu-gang
    Wu Wei-chun
    Wang Hao
    CHINESE MEDICAL JOURNAL, 2013, 126 (22) : 4227 - 4231
  • [7] Left atrial minimum volume by real-time three-dimensional echocardiography as an indicator of diastolic dysfunction
    LIN Qiong-wen
    WANG Wu-gang
    WU Wei-chun
    WANG Hao
    中华医学杂志(英文版), 2013, 126 (22) : 4227 - 4231
  • [8] Left atrial volume by real-time three-dimensional echocardiography: Validation by multidetector computed tomography
    Miyasaka, Yoko
    Haiden, Mio
    Aota, Yasuko
    Takada, Atsuaki
    Sato, Yuji
    Kubota, Yuichi
    Oshi, Chihiro
    Kimura, Yutaka
    Takehana, Kazuya
    Iwasaka, Toshiji
    CIRCULATION, 2007, 116 (16) : 328 - 328
  • [9] Real-Time Three-Dimensional Echocardiography for Left Atrial Appendage Ligation
    Matyal, Robina
    Karthik, Swaminathan
    Subramaniam, Balachundhar
    Panzica, Peter
    Sundar, Sugantha
    Hagberg, Robert
    Jervis, Karinne
    Mahmood, Feroze
    ANESTHESIA AND ANALGESIA, 2009, 108 (05): : 1467 - 1469
  • [10] Normal reference ranges for left and right atrial volume indexes and ejection fractions obtained with real-time three-dimensional echocardiography
    Aune, Erlend
    Baekkevar, Morten
    Roislien, Jo
    Rodevand, Olaf
    Otterstad, Jan Erik
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (06): : 738 - 744