Evaluation of a novel, nonspanning external fixator for treatment of unstable extra-articular fractures of the distal radius: Biomechanical comparison with a volar locking plate

被引:11
|
作者
Strauss, Eric J. [1 ]
Banerjee, Devraj [1 ]
Kummer, Frederick J. [1 ]
Tejwani, Nirmal C. [1 ]
机构
[1] NYU, Hosp Joint Dis, Dept Orthoped Surg, New York, NY 10003 USA
关键词
biomechanics; distal radius fracture; external fixation; volar locked plate;
D O I
10.1097/TA.0b013e3180eea9f0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: To compare the stability of a novel, nonspanning external fixator with a standard volar locked plate for treatment of unstable distal radius fractures. Methods: A simulated, unstable, extra-articular distal radius fracture was created in six matched pairs of fresh frozen human distal radii. One of each pair was treated with a nonspanning external fixator (Mirza Cross Pin Fixator (CPX), A.M. Surgical Inc. Smithtown, NY] and the other was treated with a volar locked plate [Distal Volar Radial Plate (DVR), Hand Innovations, Miami, FL]. Each specimen was axially loaded in central, dorsal, and volar locations, loaded in cantilever bending in volar to dorsal, dorsal to volar, and radial to ulnar directions and loaded in torsion. Load-displacement curves were generated to determine the construct stiffness for each loading schema, with comparisons made between the two treatment groups. Specimens were then cyclically loaded with 50 N axial loads applied for 1,000 and 10,000 cycles. Measurement of construct stiffness was repeated and comparisons made both between the two treatments and within treatments to their precycling stiffness. Results: There was no significant difference in the mechanical stiffness of the nonspanning external fixator and the volar locking plate after axial loading in any of the loading modalities. Cyclic loads of 1,000 and 10,000 cycles resulted in no significant difference in construct stiffness between the nonspanning external fixator and volar locked plate. However, the nonspanning external fixator demonstrated decreasing stiffness after cyclic loading with 10,000 cycles (p < 0.02). Conclusion: This study demonstrated no significant difference in the mechanical stiffness of the CPX nonspanning external fixator and volar locked plate in a cadaveric fracture model. Both constructs appear to be biomechanically equivalent in this experimental model; however, this is only one factor in the choice of fixation device for the management of unstable distal radius fractures.
引用
收藏
页码:975 / 981
页数:7
相关论文
共 50 条
  • [41] Comparative Outcome of Hybrid External Fixator Versus Primary Ilizarov Fixator in the Treatment of Open Distal Tibia Extra-Articular Fractures
    Borah, Pranab Jyoti
    Patowary, Chandan
    Das, Abhijit
    Shirdinayak, Tirupati Shivanand
    Roy, Jyoti Prakash
    Kumar, Sourabh
    INDIAN JOURNAL OF ORTHOPAEDICS, 2022, 56 (11) : 2006 - 2012
  • [42] Randomized Comparison of Volar Locking Plates and Intramedullary Nails for Unstable Distal Radius Fractures
    Plate, Johannes F.
    Gaffney, Daniel L.
    Emory, Cynthia L.
    Mannava, Sandeep
    Smith, Beth P.
    Koman, L. Andrew
    Wiesler, Ethan R.
    Li, Zhongyu
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (06): : 1095 - 1101
  • [43] Plate selection for fixation of extra-articular distal humerus fractures: A biomechanical comparison of three different implants
    Scolaro, John A.
    Hsu, Jason E.
    Svach, David J.
    Mehta, Samir
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (12): : 2040 - 2044
  • [44] Plate selection for fixation of extra-articular distal humerus fractures: A biomechanical comparison of three different implants
    Mutlu, Serhat
    Mutlu, Harun
    Erdil, Mehmet
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (08): : 1696 - 1697
  • [45] Locking plate fixation versus antegrade intramedullary nailing for the treatment of extra-articular distal femoral fractures
    Ocalan, E.
    Ustun, C. C.
    Aktuglu, K.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 : 55 - 62
  • [46] Computed Tomography Evaluation of Distal Screw Penetration in Volar Locking Plate Fixation for Intra-Articular Distal Radius Fractures
    Kaneshiro, Yasunori
    Hyun, Seungho
    Yano, Koichi
    Yokoi, Takuya
    Sakanaka, Hideki
    Hidaka, Noriaki
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2023, 48 (06): : 553 - 558
  • [47] Minimally invasive internal fixation for extra-articular distal radius fracture: Comparison between volar plate and intramedullary nail
    Thomas, Maxence
    Diaz, Juan Jose Hidalgo
    Prunieres, Guillaume
    Facca, Sybille
    Igeta, Yuka
    Liverneaux, Philippe
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2019, 105 (03) : 409 - 415
  • [48] Evaluation of a novel semicircular locking external fixator for treating fractures of long bones: Biomechanical comparison with a circular external fixator
    Bilgili, Fuat
    Sardogan, Cansu
    Bozdag, Ergun
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (04): : 1353 - 1360
  • [49] Treatment of unstable distal radius fractures with Ilizarov circular, nonbridging external fixator
    Tyllianakis, Minos
    Mylonas, Spyros
    Saridis, Alkis
    Kallivokas, Alkiviadis
    Kouzelis, Antonis
    Megas, Panagiotis
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (03): : 306 - 311
  • [50] Loss of radial height in extra-articular distal radial fracture following volar locking plate fixation
    Cheng, Ming Fai
    Chiang, Chao-Ching
    Lin, Chun-Cheng
    Chang, Ming-Chau
    Wang, Chien-Shun
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2021, 107 (05)