Evaluation of a novel, nonspanning external fixator for treatment of unstable extra-articular fractures of the distal radius: Biomechanical comparison with a volar locking plate

被引:11
|
作者
Strauss, Eric J. [1 ]
Banerjee, Devraj [1 ]
Kummer, Frederick J. [1 ]
Tejwani, Nirmal C. [1 ]
机构
[1] NYU, Hosp Joint Dis, Dept Orthoped Surg, New York, NY 10003 USA
来源
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE | 2008年 / 64卷 / 04期
关键词
biomechanics; distal radius fracture; external fixation; volar locked plate;
D O I
10.1097/TA.0b013e3180eea9f0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: To compare the stability of a novel, nonspanning external fixator with a standard volar locked plate for treatment of unstable distal radius fractures. Methods: A simulated, unstable, extra-articular distal radius fracture was created in six matched pairs of fresh frozen human distal radii. One of each pair was treated with a nonspanning external fixator (Mirza Cross Pin Fixator (CPX), A.M. Surgical Inc. Smithtown, NY] and the other was treated with a volar locked plate [Distal Volar Radial Plate (DVR), Hand Innovations, Miami, FL]. Each specimen was axially loaded in central, dorsal, and volar locations, loaded in cantilever bending in volar to dorsal, dorsal to volar, and radial to ulnar directions and loaded in torsion. Load-displacement curves were generated to determine the construct stiffness for each loading schema, with comparisons made between the two treatment groups. Specimens were then cyclically loaded with 50 N axial loads applied for 1,000 and 10,000 cycles. Measurement of construct stiffness was repeated and comparisons made both between the two treatments and within treatments to their precycling stiffness. Results: There was no significant difference in the mechanical stiffness of the nonspanning external fixator and the volar locking plate after axial loading in any of the loading modalities. Cyclic loads of 1,000 and 10,000 cycles resulted in no significant difference in construct stiffness between the nonspanning external fixator and volar locked plate. However, the nonspanning external fixator demonstrated decreasing stiffness after cyclic loading with 10,000 cycles (p < 0.02). Conclusion: This study demonstrated no significant difference in the mechanical stiffness of the CPX nonspanning external fixator and volar locked plate in a cadaveric fracture model. Both constructs appear to be biomechanically equivalent in this experimental model; however, this is only one factor in the choice of fixation device for the management of unstable distal radius fractures.
引用
收藏
页码:975 / 981
页数:7
相关论文
共 50 条
  • [21] Intramedullary nail versus volar locking plate fixation for the treatment of extra-articular or simple intra-articular distal radius fractures: systematic review and meta-analysis
    Zhang, Bing
    Chang, Hengrui
    Yu, Kunlun
    Bai, Jiangbo
    Tian, Dehu
    Zhang, Guisheng
    Shao, Xinzhong
    Zhang, Yingze
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (10) : 2161 - 2169
  • [22] Intramedullary nail versus volar locking plate fixation for the treatment of extra-articular or simple intra-articular distal radius fractures: systematic review and meta-analysis
    Bing Zhang
    Hengrui Chang
    Kunlun Yu
    Jiangbo Bai
    Dehu Tian
    Guisheng Zhang
    Xinzhong Shao
    Yingze Zhang
    International Orthopaedics, 2017, 41 : 2161 - 2169
  • [23] A Randomized Comparison of Volar Plate and External Fixation for Intra-Articular Distal Radius Fractures
    Roh, Young Hak
    Lee, Beom Koo
    Baek, Jong Ryoon
    Noh, Jung Ho
    Gong, Hyun Sik
    Baek, Goo Hyun
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (01): : 34 - 41
  • [24] The distal-medial pilot hole: A simple way to ease volar plate positioning in extra-articular distal radius fractures
    Chelli, Mikael
    Bronsard, Nicolas
    Gonzalez, Jean-Francois
    Blasco, Laurent
    Gauci, Marc-Olivier
    Boileau, Pascal
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (03): : 779 - 782
  • [25] Prospective Randomized Study Comparing the External Fixator and Volar Locking Plate in Intraarticular Distal Radius Fractures: Which Is Better?
    Sharma, Aryan
    Pathak, Subodh
    Sandhu, Harinder
    Bagtharia, Priyank
    Kumar, Naveen
    Bajwa, Rajdeep S.
    Pruthi, Vineet
    Chawla, Jasneet S.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (02)
  • [26] Efficacy of volar locking plate fixation for unstable distal radius fractures in elderly patients
    Wang, Minghui
    Wang, Bin
    Wang, Xiuhui
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (02): : 1185 - 1191
  • [27] Single locking compression plate fixation of extra-articular distal humeral fractures
    Kumar M.N.
    Ravishankar M.R.
    Manur R.
    Journal of Orthopaedics and Traumatology, 2015, 16 (2) : 99 - 104
  • [28] Is the Addition of a Foot Ring to the Circular External Fixator Necessary in the Treatment of Extra-Articular Distal Tibia Fractures?
    Erdil, Mehmet
    Ozkunt, Okan
    Polat, Gokhan
    Ceylan, Hasan Huseyin
    Ersen, Ali
    Kara, Deniz
    Sen, Cengiz
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2014, 28 (09) : E216 - E220
  • [29] How Many Screws Are Needed for Reliable Stability of Extra-articular Nonosteoporotic Distal Radius Fractures Fixed with Volar Locking Plates?
    Jung, Hyoung-Seok
    Jung, Han Sol
    Baek, Suk-Ho
    Lee, Jae Sung
    CLINICS IN ORTHOPEDIC SURGERY, 2020, 12 (01) : 22 - 28
  • [30] Retraction Note to: Single volar locking plating for the intra- and extra-articular distal radius fractures with dorsal metaphyseal comminution
    Xue-yang Gui
    Zhao-hui Cheng
    Hong-fei Shi
    Yi-xin Chen
    Jin Xiong
    Jun-fei Wang
    Xu-sheng Qiu
    Zi-tao Zhang
    Journal of Orthopaedic Surgery and Research, 17