Digital sampling setup for calibration of strain gauge bridge calibration unit BN100

被引:0
|
作者
Maslan, Stanislav [1 ]
Sira, Martin [1 ]
Skalicka, Tereza [1 ]
机构
[1] Czech Metrol Inst, Okruzni 31, Brno 63800, Czech Republic
关键词
Impedance; inductive voltage divider; voltage ratio; strain gauge;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes minimalistic, economic, automated, digital sampling calibration setup for calibration of a strain gauge bridge calibration unit BN100 or similar high division ratio dividers. The setup uses impedance divider instead of the IVD as the reference divider. It achieves comparable or better uncertainty for division ratios below 1 mV/V compared to the IVD based methods. For 1 mV/V the expanded uncertainty (k = 2) is 8 nV/V from the input.
引用
收藏
页数:2
相关论文
共 50 条
  • [41] Calibration of Rogowski Coils at Power Frequencies Using Digital Sampling
    Djokic, Branislav
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (04) : 751 - 755
  • [42] A New Calibration Transformer and Measurement Setup for Bridge Standard Calibrations Up To 5 kHz
    Beug, M. Florian
    Kolling, Axel
    Moser, Harald
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2017, 66 (06) : 1531 - 1538
  • [43] Humidity and temperature effects on torque transducers, bridge calibration unit and amplifiers
    Khaled, K. M.
    Roeske, D.
    Abuelezz, A. E.
    Elsherbiny, M. G.
    MEASUREMENT, 2015, 74 : 31 - 42
  • [44] Digital Calibration of DAC Unit Elements Mismatch in Pipelined ADCs
    Mafi, Hamidreza
    Yavari, Mohammad
    Shamsi, Hossein
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2016, 63 (01) : 34 - 45
  • [45] MODIFIED CALIBRATION UNIT FOR GENERAL-PURPOSE DIGITAL VOLTMETERS
    KOTELNIKOV, NI
    MEASUREMENT TECHNIQUES USSR, 1988, 31 (04): : 398 - 398
  • [46] Calibration of Asphalt Strain Transducers by Using Digital Image Correlation
    Burnham, Thomas R.
    Huerta, Santiago
    Olson, Steven C.
    TRANSPORTATION RESEARCH RECORD, 2017, (2640) : 49 - 57
  • [47] A digitally assisted IVD calibration bridge using a programmable digital detector
    Jain, Priyanka
    Sathish
    Kumar, Sachin
    Singh, Nidhi
    John, Thomas
    Biswas, J. C.
    MEASUREMENT, 2023, 206
  • [48] Bayesian model calibration and damage detection for a digital twin of a bridge demonstrator
    Titscher, Thomas
    van Dijk, Thomas
    Kadoke, Daniel
    Robens-Radermacher, Annika
    Herrman, Ralf
    Unger, Joerg F.
    ENGINEERING REPORTS, 2023, 5 (11)
  • [49] CALIBRATION RESEARCH AND EXPERIMENT ON THE CORE PARAMETERS OF HIGH-TEMPERATURE STRAIN GAUGE
    Wang Wen-rui
    Zhang Jia-ming
    Nie Shuai
    JOURNAL OF INVESTIGATIVE MEDICINE, 2014, 62 (08) : S46 - S46
  • [50] CALIBRATION OF THE MERCURY-IN-SILASTIC STRAIN-GAUGE IN TENDON LOAD EXPERIMENTS
    RIEMERSMA, DJ
    LAMMERTINK, JLMA
    JOURNAL OF BIOMECHANICS, 1988, 21 (06) : 469 - 476