Digital sampling setup for calibration of strain gauge bridge calibration unit BN100

被引:0
|
作者
Maslan, Stanislav [1 ]
Sira, Martin [1 ]
Skalicka, Tereza [1 ]
机构
[1] Czech Metrol Inst, Okruzni 31, Brno 63800, Czech Republic
关键词
Impedance; inductive voltage divider; voltage ratio; strain gauge;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes minimalistic, economic, automated, digital sampling calibration setup for calibration of a strain gauge bridge calibration unit BN100 or similar high division ratio dividers. The setup uses impedance divider instead of the IVD as the reference divider. It achieves comparable or better uncertainty for division ratios below 1 mV/V compared to the IVD based methods. For 1 mV/V the expanded uncertainty (k = 2) is 8 nV/V from the input.
引用
收藏
页数:2
相关论文
共 50 条
  • [31] Examination of Systematic Bench Errors for Calibration of a Strain-Gauge Balance
    Bol'shakova, A. A.
    Volobuev, V. S.
    Gorbushin, A. R.
    Petronevich, V. V.
    MEASUREMENT TECHNIQUES, 2017, 60 (08) : 763 - 770
  • [32] Strain Gauge Calibration for High Speed Weight-in-Motion Station
    Socha, Agnieszka
    Izydorczyk, Jacek
    SENSORS, 2024, 24 (15)
  • [33] An Analytical Approach in Dynamic Calibration of Strain Gauge Balances for Aerodynamic Measurements
    Bighashdel, A.
    Zare, H.
    Pourtakdoust, Seid H.
    Sheikhy, Ali A.
    IEEE SENSORS JOURNAL, 2018, 18 (09) : 3572 - 3579
  • [34] DEVICE FOR RESISTANCE-STRAIN GAUGE CALIBRATION AT LOW-TEMPERATURES
    DORIN, VA
    SMOLIN, YZ
    MEASUREMENT TECHNIQUES, 1977, 20 (12) : 1709 - 1710
  • [35] Calibration of Rogowski coils at power frequencies using digital sampling
    Djokic, Branislav
    2008 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2008, : 462 - 463
  • [36] Calibration of 90° Phase Difference Measured by Digital Sampling Method
    Feng, Jian
    Shi, Leibing
    Xu, Feng
    Pan, Yang
    Pan, Xianlin
    Zhang, Jiangtao
    2016 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2016), 2016,
  • [37] An efficient calibration method for digital bandwidth interleaving sampling system
    Ma, Yubo
    Wu, Jie
    Jiang, Xiaochang
    Xu, Boyi
    Qi, Shengyu
    JOURNAL OF INSTRUMENTATION, 2023, 18 (11):
  • [38] Calibration of Electronic Transformer with Digital Output Based on Synchronous Sampling
    Pan, Yang
    Wang, Yili
    Lai, Lei
    Shi, Leibing
    Huang, Hongtao
    Lu, Chunfeng
    2016 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2016), 2016,
  • [39] Calibration of Electronic Transformer Tester using Digital Sampling method
    Pan, Yang
    Shi, Leibing
    Feng, Jian
    Zhou, Liren
    Sun, Weibin
    Li, Ruoshi
    Zhang, Minghui
    2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,
  • [40] The Sampling Error Calibration and Imaging of Synthetic Aperture Digital Radiometer
    Zhu, Lu
    Liu, Yuanyuan
    Huang, Dechang
    2012 10TH INTERNATIONAL SYMPOSIUM ON ANTENNAS, PROPAGATION & EM THEORY (ISAPE), 2012, : 604 - 607