Optimization of geothermal interaction of a double U-tube borehole heat exchanger for space heating and cooling applications using Taguchi method and utility concept

被引:45
|
作者
Kumar, Satish [1 ]
Murugesan, K. [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Mech & Ind Engn, Roorkee 247667, Uttar Pradesh, India
关键词
Double U-tube borehole heat exchanger; Ground source heat pump system; Optimization of heat transfer; Space cooling and heating applications; Taguchi method; Utility concept; THERMAL PERFORMANCE; MULTIRESPONSE OPTIMIZATION; PUMP SYSTEM; INTERFERENCE;
D O I
10.1016/j.geothermics.2019.101723
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Optimization results for thermal interaction of a double U-tube borehole heat exchanger (BHE) used along with a 5 ton capacity ground source heat pump system (GSHP), are discussed in this paper. Heat transfer from the BHE is computed using thermal resistance concept for space cooling and heating mode operations. The main objective of optimization is to achieve maximum heat extraction during space heating and maximum heat rejection during space cooling operations. For the purpose of optimization, eight control variables consisting of geometric parameters, thermo-physical parameters and mass flow rate are considered at three levels for a series connected double U-tube BHE of 120 m depth. For Taguchi method L-27 orthogonal array has been employed for the computation of heat transfer and S/N ratios for both modes of operations. Results obtained show that optimum values of 9270 W and 7210 W heat can be rejected to and extracted from the ground. Taguchi results are combined to obtain a single set of optimum levels of control variables using the utility concept. Mass flow rate of water in the BHE is found to be the most influential variable. For variation in the duration of cooling and heating mode operations, the optimum heat that could be rejected and absorbed becomes the same and equal to 6180 W for equal duration. It is observed that the heat transfer calculated from the utility concept is 11.11% and 42.86% less than those values calculated by Taguchi method for cooling and heating mode of operations respectively.
引用
收藏
页数:17
相关论文
共 45 条
  • [31] Optimization of Process Parameters of Ground Source Heat Pumps for Space Heating Applications with Taguchi Method
    Ozdemir, Mustafa Bahadir
    JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2018, 21 (04): : 991 - 998
  • [32] Coupling of geothermal heat pumps with thermal solar collectors using double U-tube boreholes with two independent circuits
    Eslami-nejad, Parham
    Bernier, Michel
    APPLIED THERMAL ENGINEERING, 2011, 31 (14-15) : 3066 - 3077
  • [33] Optimization of Solar Coupled Heat Pump System for Space Heating Application using Taguchi Method
    Verma, Vikas
    Murugesan, K.
    Kakati, Biraj Kumar
    INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND GREEN TECHNOLOGY 2018, 2019, 268
  • [34] Performance enhancement of borehole ground source heat pump using single U-tube heat exchanger with a novel oval cross-section (SUO) and a novel spacer
    Serageldin, Ahmed A.
    Sakata, Yoshitaka
    Katsura, Takao
    Nagano, Katsunori
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2020, 42
  • [35] Techno-environmental Assessment of Integrated Nocturnal Solar Collector and U-Tube Ground-source Heat Exchanger for Space Cooling Application in UAE
    Rahman, Shek A.
    Shaikh, Bismah
    Shah, Shiekh Khaleduzzaman
    Hachicha, Ahmed
    Assad, Mamdouh Al Haj
    2021 10TH INTERNATIONAL CONFERENCE ON POWER SCIENCE AND ENGINEERING (ICPSE 2021), 2021, : 121 - 126
  • [36] Lessen Pressure Drop and Forecasting Thermal Performance in U-Tube Heat Exchanger Using Chimp Optimization and Deep Belief Neural Network
    Prasad, Shailandra Kumar
    Sinha, Mrityunjay Kumar
    OPTICAL MEMORY AND NEURAL NETWORKS, 2023, 32 (04) : 275 - 294
  • [38] Analysis of double U-tube ground heat exchanger for renewable energy applications with two-region simulation model by combining analytical and numerical techniques
    Salilih, Elias M.
    Abu-Hamdeh, Nidal H.
    Oztop, Hakan F.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2021, 123
  • [39] Evaluation of the long-term performance of the deep U-type borehole heat exchanger on different geological parameters using the Taguchi method
    Jiang, Jinghua
    Wang, Fenghao
    Yang, Xiong
    Zhang, Yuping
    Deng, Jiewen
    Wei, Qingpeng
    Cai, Wanlong
    Chen, Chaofan
    JOURNAL OF BUILDING ENGINEERING, 2022, 59
  • [40] Optimization of double diffusive mixed convection in a BFS channel filled with Alumina nanoparticle using Taguchi method and utility concept
    Ratnadeep Nath
    Murugesan Krishnan
    Scientific Reports, 9