Comparison study of lifetime measurement techniques

被引:0
|
作者
Quinones, G [1 ]
Allen, E [1 ]
机构
[1] Appl Mat Inc, Santa Clara, CA 95054 USA
关键词
lifetime; diffusion length; surface photovoltage (SPV); electrolytic metal tracer (ELYMAT); microwave photoconductivity decay (mu-PCD); RTO;
D O I
10.1117/12.324401
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A comparison study was conducted between three different techniques used to resolve iron contamination in silicon. Fourteen 8 " p-type Si wafers were implanted with iron at seven doses ranging from 1x10(8) to 1x10(12) cm(-2). Ail 14 wafers including monitors were processed through an RTP chamber at 1100 degrees C for 6 min. Oxide thickness was measured on an ellipsometer. The wafers were measured by optical and thermal activation SPV, then the wafers were split in two sets. One set of seven wafers was measured by ELYMAT and the other set was measured by mu-PCD. Two different passivation techniques were used for mu-PCD, oxide and ethanol-iodine passivation. At low implant dose all three techniques have limitations. However mu-PCD shows the highest lifetime. At high Fe concentrations all three techniques tend to agree.
引用
收藏
页码:137 / 146
页数:10
相关论文
共 50 条
  • [31] Measurement of Evapotranspiration in Turfgrass: A Comparison of Techniques
    Peterson, K. W.
    Bremer, D. J.
    Shonkwiler, K. B.
    Ham, J. M.
    AGRONOMY JOURNAL, 2017, 109 (05) : 2190 - 2198
  • [32] MEASUREMENT TECHNIQUES FOR MELANOMA - A STATISTICAL COMPARISON
    WARREN, BF
    DAVIES, JD
    JOURNAL OF CLINICAL PATHOLOGY, 1991, 44 (03) : 263 - 263
  • [33] Comparison of torsional vibration measurement techniques
    Janssens, K.
    Britte, L.
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING (ISMA2012) / INTERNATIONAL CONFERENCE ON UNCERTAINTY IN STRUCTURAL DYNAMICS (USD2012), 2012, : 1447 - 1461
  • [34] MEASUREMENT TECHNIQUES FOR MELANOMA - A STATISTICAL COMPARISON
    CALDER, CJ
    CAMPBELL, AP
    PLASTOW, SR
    JOURNAL OF CLINICAL PATHOLOGY, 1990, 43 (11) : 922 - 923
  • [35] MEASUREMENT TECHNIQUES FOR MELANOMA - A STATISTICAL COMPARISON
    GOULDING, H
    GRADWELL, E
    JOURNAL OF CLINICAL PATHOLOGY, 1991, 44 (09) : 791 - 791
  • [36] MEASUREMENT OF REAERATION IN STREAMS - COMPARISON OF TECHNIQUES
    BICUDO, JR
    JAMES, A
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1989, 115 (05): : 992 - 1010
  • [37] Comparison among lifetime techniques for the detection of transition metal contamination
    Polignano, ML
    Cazzaniga, F
    Sabbadini, A
    Queirolo, G
    Cacciato, A
    DiBartolo, A
    MATERIALS SCIENCE AND ENGINEERING B-SOLID STATE MATERIALS FOR ADVANCED TECHNOLOGY, 1996, 42 (1-3): : 157 - 163
  • [38] A Comparison of the Microwave Photoconductivity Decay and Open-Circuit Voltage Decay Lifetime Measurement Techniques for Lifetime-Enhanced 4H-SiC Epilayers
    Van Brunt, Edward
    Agarwal, Anant
    Burk, Al
    Cheng, Lin
    O'Loughlin, Michael
    Palmour, John
    Suvorov, Alexander
    JOURNAL OF ELECTRONIC MATERIALS, 2014, 43 (04) : 809 - 813
  • [39] A Comparison of the Microwave Photoconductivity Decay and Open-Circuit Voltage Decay Lifetime Measurement Techniques for Lifetime-Enhanced 4H-SiC Epilayers
    Edward Van Brunt
    Anant Agarwal
    Al Burk
    Lin Cheng
    Michael O’Loughlin
    John Palmour
    Alexander Suvorov
    Journal of Electronic Materials, 2014, 43 : 809 - 813
  • [40] Measurement and study of fluorescence lifetime of molecules and ions
    Wang, Wenkyun
    Yu, Jiaolu
    Yu, Yingning
    Yu, Hua
    Hou, Shifa
    Guo, Chuan
    Jiguang Zazhi/Laser Journal, 1993, 14 (03): : 127 - 130