Diagnostic validation of a deep learning nodule detection algorithm in low-dose chest CT: determination of optimized dose thresholds in a virtual screening scenario

被引:10
|
作者
Peters, Alan A. [1 ]
Huber, Adrian T. [1 ]
Obmann, Verena C. [1 ]
Heverhagen, Johannes T. [1 ,2 ,3 ]
Christe, Andreas [1 ]
Ebner, Lukas [1 ]
机构
[1] Univ Bern, Bern Univ Hosp, Dept Diagnost Intervent & Pediat Radiol DIPR, Inselspital Bern, CH-3010 Bern, Switzerland
[2] Univ Bern, Dept BioMed Res, Expt Radiol, CH-3008 Bern, Switzerland
[3] Ohio State Univ, Dept Radiol, Columbus, OH 43210 USA
关键词
Lung neoplasms; Artificial intelligence; Deep learning; Computer-assisted diagnosis; Radiographic phantoms; COMPUTER-AIDED-DETECTION; LUNG-CANCER; ITERATIVE RECONSTRUCTION; RADIATION-EXPOSURE; PULMONARY NODULES; CAD; TOMOGRAPHY; PERFORMANCE; EQUIVALENT; IMAGES;
D O I
10.1007/s00330-021-08511-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives This study was conducted to evaluate the effect of dose reduction on the performance of a deep learning (DL)-based computer-aided diagnosis (CAD) system regarding pulmonary nodule detection in a virtual screening scenario. Methods Sixty-eight anthropomorphic chest phantoms were equipped with 329 nodules (150 ground glass, 179 solid) with four sizes (5 mm, 8 mm, 10 mm, 12 mm) and scanned with nine tube voltage/current combinations. The examinations were analyzed by a commercially available DL-based CAD system. The results were compared by a comparison of proportions. Logistic regression was performed to evaluate the impact of tube voltage, tube current, nodule size, nodule density, and nodule location. Results The combination with the lowest effective dose (E) and unimpaired detection rate was 80 kV/50 mAs (sensitivity: 97.9%, mean false-positive rate (FPR): 1.9, mean CTDIvol: 1.2 +/- 0.4 mGy, mean E: 0.66 mSv). Logistic regression revealed that tube voltage and current had the greatest impact on the detection rate, while nodule size and density had no significant influence. Conclusions The optimal tube voltage/current combination proposed in this study (80 kV/50 mAs) is comparable to the proposed combinations in similar studies, which mostly dealt with conventional CAD software. Modification of tube voltage and tube current has a significant impact on the performance of DL-based CAD software in pulmonary nodule detection regardless of their size and composition.
引用
收藏
页码:4324 / 4332
页数:9
相关论文
共 50 条
  • [31] A Challenge for Emphysema Quantification Using a Deep Learning Algorithm With Low-dose Chest Computed Tomography
    Choi, Hyewon
    Kim, Hyungjin
    Jin, Kwang Nam
    Jeong, Yeon Joo
    Chae, Kum Ju
    Lee, Kyung Hee
    Yong, Hwan Seok
    Gil, Bomi
    Lee, Hye-Jeong
    Lee, Ki Yeol
    Jeon, Kyung Nyeo
    Yi, Jaeyoun
    Seo, Sola
    Ahn, Chulkyun
    Lee, Joonhyung
    Oh, Kyuhyup
    Goo, Jin Mo
    JOURNAL OF THORACIC IMAGING, 2022, 37 (04) : 253 - 261
  • [32] Generalizability of a Deep Learning Airway Segmentation Algorithm to a Blinded Low-Dose CT Dataset
    Nadeem, Syed Ahmed
    Comellas, Alejandro P.
    Hoffman, Eric A.
    Saha, Punam K.
    MEDICAL IMAGING 2021: IMAGE PROCESSING, 2021, 11596
  • [33] Validation of an AI-based algorithm for measurement of the thoracic aortic diameter in low-dose chest CT
    Hamelink, I. Iris
    de Heide, E. Erik Jan
    Pelgrim, G. J. Gert Jan
    Kwee, T. C. Thomas
    van Ooijen, P. M. A. Peter
    de Bock, G. H. Truuske
    Vliegenthart, R. Rozemarijn
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 167
  • [34] Development of deep learning-assisted overscan decision algorithm in low-dose chest CT: Application to lung cancer screening in Korean National CT accreditation program
    Kim, Sihwan
    Jeong, Woo Kyoung
    Choi, Jin Hwa
    Kim, Jong Hyo
    Chun, Minsoo
    PLOS ONE, 2022, 17 (09):
  • [35] Virtual colonoscopy screening with ultra low-dose CT: A simulation study
    Wang, Jing
    Wang, Su
    Li, Lihong
    Lu, Hongbing
    Liang, Zhengrong
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4564 - +
  • [36] Automated aortic calcification detection in low-dose chest CT images
    Xie, Yiting
    Htwe, Yu Maw
    Padgett, Jennifer
    Henschke, Claudia
    Yankelevitz, David
    Reeves, Anthony P.
    MEDICAL IMAGING 2014: COMPUTER-AIDED DIAGNOSIS, 2014, 9035
  • [37] FRAMELET DENOISING FOR LOW-DOSE CT USING DEEP LEARNING
    Kang, Eunhee
    Ye, Jong Chul
    2018 IEEE 15TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2018), 2018, : 311 - 314
  • [38] Low-Dose CT Image Reconstruction With a Deep Learning Prior
    Park, Hyoung Suk
    Kim, Kyungsang
    Jeon, Kiwan
    IEEE ACCESS, 2020, 8 : 158647 - 158655
  • [39] Pulmonary nodule detection with low-dose CT of the lung: Agreement among radiologists
    Leader, JK
    Warfel, TE
    Fuhrman, CR
    Golla, SK
    Weissfeld, JL
    Avila, RS
    Turner, WD
    Zheng, B
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (04) : 973 - 978
  • [40] A Multimodal Neural Network for Lung Nodule Detection with Low-Dose CT Images
    Cao, Wenming
    Wu, Rui
    Cao, Guitao
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 124 : 37 - 38