Diagnostic validation of a deep learning nodule detection algorithm in low-dose chest CT: determination of optimized dose thresholds in a virtual screening scenario

被引:10
|
作者
Peters, Alan A. [1 ]
Huber, Adrian T. [1 ]
Obmann, Verena C. [1 ]
Heverhagen, Johannes T. [1 ,2 ,3 ]
Christe, Andreas [1 ]
Ebner, Lukas [1 ]
机构
[1] Univ Bern, Bern Univ Hosp, Dept Diagnost Intervent & Pediat Radiol DIPR, Inselspital Bern, CH-3010 Bern, Switzerland
[2] Univ Bern, Dept BioMed Res, Expt Radiol, CH-3008 Bern, Switzerland
[3] Ohio State Univ, Dept Radiol, Columbus, OH 43210 USA
关键词
Lung neoplasms; Artificial intelligence; Deep learning; Computer-assisted diagnosis; Radiographic phantoms; COMPUTER-AIDED-DETECTION; LUNG-CANCER; ITERATIVE RECONSTRUCTION; RADIATION-EXPOSURE; PULMONARY NODULES; CAD; TOMOGRAPHY; PERFORMANCE; EQUIVALENT; IMAGES;
D O I
10.1007/s00330-021-08511-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives This study was conducted to evaluate the effect of dose reduction on the performance of a deep learning (DL)-based computer-aided diagnosis (CAD) system regarding pulmonary nodule detection in a virtual screening scenario. Methods Sixty-eight anthropomorphic chest phantoms were equipped with 329 nodules (150 ground glass, 179 solid) with four sizes (5 mm, 8 mm, 10 mm, 12 mm) and scanned with nine tube voltage/current combinations. The examinations were analyzed by a commercially available DL-based CAD system. The results were compared by a comparison of proportions. Logistic regression was performed to evaluate the impact of tube voltage, tube current, nodule size, nodule density, and nodule location. Results The combination with the lowest effective dose (E) and unimpaired detection rate was 80 kV/50 mAs (sensitivity: 97.9%, mean false-positive rate (FPR): 1.9, mean CTDIvol: 1.2 +/- 0.4 mGy, mean E: 0.66 mSv). Logistic regression revealed that tube voltage and current had the greatest impact on the detection rate, while nodule size and density had no significant influence. Conclusions The optimal tube voltage/current combination proposed in this study (80 kV/50 mAs) is comparable to the proposed combinations in similar studies, which mostly dealt with conventional CAD software. Modification of tube voltage and tube current has a significant impact on the performance of DL-based CAD software in pulmonary nodule detection regardless of their size and composition.
引用
收藏
页码:4324 / 4332
页数:9
相关论文
共 50 条
  • [21] Low-Dose Spiral CT Screening and Evaluation of the Solitary Pulmonary Nodule
    Brawley, Otis W.
    Flenaugh, Eric L.
    ONCOLOGY-NEW YORK, 2014, 28 (05): : 441 - 446
  • [22] Image quality improvement in low-dose chest CT with deep learning image reconstruction
    Tian, Qian
    Li, Xinyu
    Li, Jianying
    Cheng, Yannan
    Niu, Xinyi
    Zhu, Shumeng
    Xu, Wenting
    Guo, Jianxin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (12):
  • [23] Automated lung nodule detection at low-dose CT: Preliminary experience
    Goo, JM
    Lee, JW
    Lee, HJ
    Kim, S
    Kim, JH
    Im, JG
    KOREAN JOURNAL OF RADIOLOGY, 2003, 4 (04) : 211 - 216
  • [24] Ultra-Low Dose Chest CT with Denoising for Lung Nodule Detection
    Kerpel, Ariel
    Marom, Edith Michelle
    Green, Michael
    Eifer, Michal
    Konen, Eli
    Mayer, Arnaldo
    Cuellar, Sonia L. Betancourt
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2021, 23 (09): : 550 - 555
  • [25] Nodule Size is Poorly Represented by Nodule Diameter in Low-Dose CT Lung Cancer Screening
    Heuvelmans, Marjolein
    Vliegenthart, Rozemarijn
    Van Ooijen, Peter
    De Koning, Harry
    Oudkerk, Matthijs
    JOURNAL OF THORACIC ONCOLOGY, 2017, 12 (01) : S567 - S568
  • [26] Image Quality and Diagnostic Performance of Low-Dose Liver CT with Deep Learning Reconstruction versus Standard-Dose CT
    Lee, Dong Ho
    Lee, Jeong Min
    Lee, Chang Hee
    Afat, Saif
    Othman, Ahmed
    RADIOLOGY-ARTIFICIAL INTELLIGENCE, 2024, 6 (02)
  • [27] Lung age estimation from low-dose chest CT images use deep learning
    Kikuno, Haruto
    Tanaka, Rie
    Kobayashi, Satoshi
    Matsunaga, Tetsuo
    Minami, Tetsuya
    Shiraishi, Junji
    COMPUTER-AIDED DIAGNOSIS, MEDICAL IMAGING 2024, 2024, 12927
  • [28] The Value of Deep Learning Image Reconstruction in Improving the Quality of Low-Dose Chest CT Images
    Jiang, Jiu-Ming
    Miao, Lei
    Liang, Xin
    Liu, Zhuo-Heng
    Zhang, Li
    Li, Meng
    DIAGNOSTICS, 2022, 12 (10)
  • [29] Direct Prediction of Cardiovascular Mortality from Low-dose Chest CT using Deep Learning
    van Velzen, Sanne G. M.
    Zreik, Majd
    Lessmann, Nikolas
    Viergever, Max A.
    de Jong, Pim A.
    Verkooijen, Helena M.
    Isgum, Ivana
    MEDICAL IMAGING 2019: IMAGE PROCESSING, 2019, 10949
  • [30] A Pulmonary Nodule Detection Algorithm Based on Low Dose CT Images
    Yang, Qian
    HuiqinJiang
    LingMa
    XiaozhenDu
    Gao, Jianbo
    THIRD INTERNATIONAL SYMPOSIUM ON IMAGE COMPUTING AND DIGITAL MEDICINE (ISICDM 2019), 2019, : 239 - 243