Diagnosis of cerebral aneurysm using 3-dimensional digital subtraction angiography

被引:0
|
作者
Nanba, R
Houkin, K
Kuroda, S
Iwasaki, Y
Ushikoshi, S
Asano, T
Miyasaka, K
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Neurosurg, Kita Ku, Sapporo, Hokkaido 0608638, Japan
[2] Hokkaido Univ, Grad Sch Med, Dept Radiol, Kita Ku, Sapporo, Hokkaido 0608638, Japan
来源
NEUROLOGICAL SURGERY | 2001年 / 29卷 / 05期
关键词
intracranial aneurysm; three dimensional digital subtraction angiography;
D O I
暂无
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Recent rapid advancement in the technology of magnetic resonance angiography and 5-dimensional computed tomography angiography has opened the door to a less-invasive diagnostic routine for the treatment of cerebral aneurysms. However, from the viewpoint of decision making concerning which treatment to use; conservative therapy; surgical intervention; or endovascular treatment, much more precise information is necessary. Recent progress of rotation digital subtraction angiography has introduced 3-dimensional digital subtraction angiography. In the past year, 28 cases involving 39 aneurysms have been studied using S-dimensional angiography. This study was carried out, using a rotating C-arm, which rotates 220 degrees in 5.8 seconds. Air raw data gathered was transferred to the workstation for image reconstruction. The purpose of this study was to evaluate the clinical potential of 3-dimensional digital subtraction angiography for the diagnosis of the cerebral aneurysms.
引用
收藏
页码:393 / 399
页数:7
相关论文
共 50 条
  • [41] THE DIAGNOSIS OF AORTIC RUPTURE BY DIGITAL SUBTRACTION ANGIOGRAPHY
    RAUBER, K
    KOLLATH, J
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1983, 139 (02): : 167 - 170
  • [42] 3-DIMENSIONAL TIME-OF-FLIGHT MAGNETIC-RESONANCE ANGIOGRAPHY IN CAROTID-ARTERY SURGERY - A COMPARISON WITH DIGITAL SUBTRACTION ANGIOGRAPHY
    CHIESA, R
    MELISSANO, G
    CASTELLANO, R
    TRIULZI, F
    ANZALONE, N
    VEGLIA, F
    SCOTTI, G
    GROSSI, A
    EUROPEAN JOURNAL OF VASCULAR SURGERY, 1993, 7 (02): : 171 - 176
  • [43] The characteristics of the anterior communicating artery aneurysm complex by three-dimensional digital subtraction angiography
    Takashi Sadatomo
    Kiyoshi Yuki
    Keisuke Migita
    Eiji Taniguchi
    Yasunori Kodama
    Kaoru Kurisu
    Neurosurgical Review, 2006, 29 : 201 - 207
  • [44] DIAGNOSIS OF RUPTURED AND UNRUPTURED CEREBRAL ANEURYSMS WITH 3-DIMENSIONAL CT ANGIOGRAPHY (3D-CTA)
    TANABE, S
    OHTAKI, M
    UEDE, T
    HASHI, K
    SUZUKI, S
    TAKAHASHI, H
    NEUROLOGICAL SURGERY, 1995, 23 (09): : 787 - 795
  • [45] Surgical views from three-dimensional digital subtraction angiography for the planning of aneurysm surgery
    Thines, L.
    Taschner, C.
    Lejeune, J.-P.
    Le Thuc, V.
    Pruv, J.-P.
    Bourgeois, P.
    Leclerc, X.
    JOURNAL OF NEURORADIOLOGY, 2007, 34 (03) : 205 - 211
  • [46] The characteristics of the anterior communicating artery aneurysm complex by three-dimensional digital subtraction angiography
    Sadatomo, T
    Yuki, K
    Migita, K
    Taniguchi, E
    Kodama, Y
    Kurisu, K
    NEUROSURGICAL REVIEW, 2006, 29 (03) : 201 - 207
  • [47] Anatomical reconstruction of cerebral vessels as numerical grid models using three-dimensional digital subtraction angiography
    Hassan, T
    Saito, T
    Timofeev, E
    Ezura, M
    Takahashi, A
    Takayama, K
    RIVISTA DI NEURORADIOLOGIA, 2003, 16 (05): : 961 - 964
  • [48] 3-DIMENSIONAL SELECTIVE ANGIOGRAPHY IN DIAGNOSIS OF RENAL MASSES
    HEGEDUS, V
    ACTA RADIOLOGICA-DIAGNOSIS, 1974, 15 (04): : 401 - 412
  • [49] MOYAMOYA DISEASE - DIAGNOSIS WITH 3-DIMENSIONAL CT ANGIOGRAPHY
    TSUCHIYA, K
    MAKITA, K
    FURUI, S
    NEURORADIOLOGY, 1994, 36 (06) : 432 - 434
  • [50] Comparative Analysis of 3-Dimensional Rotation Angiography versus 3-Dimensional Computed Tomography Angiography for Intracranial Aneurysm Treatment Detection and Planning
    Park, Jonathan
    Salamon, Noriko
    Duckwiler, Gary
    Vinuela, Fernando
    Sayer, James
    Villablanca, J. Pablo
    STROKE, 2013, 44 (02)