Diagnosis of cerebral aneurysm using 3-dimensional digital subtraction angiography

被引:0
|
作者
Nanba, R
Houkin, K
Kuroda, S
Iwasaki, Y
Ushikoshi, S
Asano, T
Miyasaka, K
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Neurosurg, Kita Ku, Sapporo, Hokkaido 0608638, Japan
[2] Hokkaido Univ, Grad Sch Med, Dept Radiol, Kita Ku, Sapporo, Hokkaido 0608638, Japan
来源
NEUROLOGICAL SURGERY | 2001年 / 29卷 / 05期
关键词
intracranial aneurysm; three dimensional digital subtraction angiography;
D O I
暂无
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Recent rapid advancement in the technology of magnetic resonance angiography and 5-dimensional computed tomography angiography has opened the door to a less-invasive diagnostic routine for the treatment of cerebral aneurysms. However, from the viewpoint of decision making concerning which treatment to use; conservative therapy; surgical intervention; or endovascular treatment, much more precise information is necessary. Recent progress of rotation digital subtraction angiography has introduced 3-dimensional digital subtraction angiography. In the past year, 28 cases involving 39 aneurysms have been studied using S-dimensional angiography. This study was carried out, using a rotating C-arm, which rotates 220 degrees in 5.8 seconds. Air raw data gathered was transferred to the workstation for image reconstruction. The purpose of this study was to evaluate the clinical potential of 3-dimensional digital subtraction angiography for the diagnosis of the cerebral aneurysms.
引用
收藏
页码:393 / 399
页数:7
相关论文
共 50 条
  • [11] Comparison of computerized tomography angiography and digital subtraction angiography in ruptured cerebral aneurysm surgery
    Poon, Tak-Lap
    Ho, Wai-Shing
    Pang, Kai-Yuen
    Wong, Chi-Keung
    SURGICAL PRACTICE, 2006, 10 (01) : 8 - 13
  • [12] Comparison of Intra- and Postoperative 3-Dimensional Digital Subtraction Angiography in Evaluation of the Surgical Result After Intracranial Aneurysm Treatment
    Marbacher, Serge
    Kienzler, Jenny C.
    Mendelowitsch, Itai
    D'Alonzo, Donato
    Andereggen, Lukas
    Diepers, Michael
    Remonda, Luca
    Fandino, Javier
    NEUROSURGERY, 2020, 87 (04) : 689 - 696
  • [13] 3-DIMENSIONAL ELASTIC SUBTRACTION SPIRAL CT ANGIOGRAPHY
    PEARLMAN, JD
    RAPTOPOULOS, VD
    KLEEFIELD, J
    RADIOLOGY, 1995, 197 : 143 - 144
  • [14] Improved Cerebral Arteriovenous Malformation Obliteration With 3-Dimensional Rotational Digital Subtraction Angiography for Radiosurgical Planning: A Retrospective Cohort Study
    Anderson, Joshua L.
    Khattab, Mohamed H.
    Sherry, Alexander D.
    Luo, Guozhen
    Chitale, Rohan V.
    Froehler, Michael T.
    Fusco, Matthew R.
    Cmelak, Anthony J.
    Attia, Albert
    NEUROSURGERY, 2021, 89 : S66 - S66
  • [15] Improved Cerebral Arteriovenous Malformation Obliteration With 3-Dimensional Rotational Digital Subtraction Angiography for Radiosurgical Planning: A Retrospective Cohort Study
    Anderson, Joshua L.
    Khattab, Mohamed H.
    Sherry, Alexander D.
    Luo, Guozhen
    Chitale, Rohan, V
    Froehler, Michael T.
    Fusco, Matthew R.
    Cmelak, Anthony J.
    Attia, Albert
    NEUROSURGERY, 2020, 88 (01) : 122 - 130
  • [16] A case of extravasation from a cerebral aneurysm during 3-dimensional computed tomography angiography
    Nagai, Mutsumi
    Koizumi, Yuiko
    Tsukue, Juriko
    Watanabe, Eiju
    SURGICAL NEUROLOGY, 2008, 69 (04): : 411 - 413
  • [17] Utility of Screening for Cerebral Vasospasm Using Digital Subtraction Angiography
    Arias, Eric J.
    Vajapey, Sravya
    Reynolds, Matthew R.
    Chicoine, Michael R.
    Rich, Keith M.
    Dacey, Ralph G., Jr.
    Dorward, Ian G.
    Derdeyn, Colin P.
    Moran, Christopher J.
    Cross, DeWitte T., III
    Zipfel, Gregory J.
    Dhar, Rajat
    STROKE, 2015, 46 (11) : 3137 - 3141
  • [18] RAPID aneurysm accurately measures aneurysm size on CT angiography compared to three-dimensional digital subtraction angiography
    Snyder, Sarah J.
    Gauden, Andrew
    Copeland, Karen
    Spiotta, Alejandro M.
    Heit, Jeremy J.
    INTERVENTIONAL NEURORADIOLOGY, 2023,
  • [19] Commentary: Improved Cerebral Arteriovenous Malformation Obliteration With 3-Dimensional Rotational Digital Subtraction Angiography for Radiosurgical Planning: A Retrospective Cohort Study
    Conti, Alfredo
    Friso, Filippo
    Tomasello, Francesco
    NEUROSURGERY, 2020, 88 (01) : E33 - E34
  • [20] 3-DIMENSIONAL DIGITAL SUBTRACTION MODELING OF CORNEAL TOPOGRAPHY
    YOUNG, JA
    SIEGEL, IM
    JOURNAL OF REFRACTIVE SURGERY, 1995, 11 (03): : 188 - 193