Diagnosis of cerebral aneurysm using 3-dimensional digital subtraction angiography

被引:0
|
作者
Nanba, R
Houkin, K
Kuroda, S
Iwasaki, Y
Ushikoshi, S
Asano, T
Miyasaka, K
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Neurosurg, Kita Ku, Sapporo, Hokkaido 0608638, Japan
[2] Hokkaido Univ, Grad Sch Med, Dept Radiol, Kita Ku, Sapporo, Hokkaido 0608638, Japan
来源
NEUROLOGICAL SURGERY | 2001年 / 29卷 / 05期
关键词
intracranial aneurysm; three dimensional digital subtraction angiography;
D O I
暂无
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Recent rapid advancement in the technology of magnetic resonance angiography and 5-dimensional computed tomography angiography has opened the door to a less-invasive diagnostic routine for the treatment of cerebral aneurysms. However, from the viewpoint of decision making concerning which treatment to use; conservative therapy; surgical intervention; or endovascular treatment, much more precise information is necessary. Recent progress of rotation digital subtraction angiography has introduced 3-dimensional digital subtraction angiography. In the past year, 28 cases involving 39 aneurysms have been studied using S-dimensional angiography. This study was carried out, using a rotating C-arm, which rotates 220 degrees in 5.8 seconds. Air raw data gathered was transferred to the workstation for image reconstruction. The purpose of this study was to evaluate the clinical potential of 3-dimensional digital subtraction angiography for the diagnosis of the cerebral aneurysms.
引用
收藏
页码:393 / 399
页数:7
相关论文
共 50 条
  • [1] 3-DIMENSIONAL DIGITAL SUBTRACTION ANGIOGRAPHY
    MIN, BG
    LEE, SJ
    LEE, TS
    KIM, HC
    PARK, JH
    HAN, MC
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1982, 29 (08) : 599 - 599
  • [2] Intravenous 3-Dimensional Digital Subtraction Angiography During Surgical Treatment of Intracranial Aneurysm
    Kan, Issei
    Kato, Naoki
    Otani, Katharina
    Abe, Yukiko
    Ishibashi, Toshihiro
    Murayama, Yuichi
    WORLD NEUROSURGERY, 2019, 126 : 533 - 536
  • [3] Virtual angioscopy using 3-dimensional rotational digital subtraction angiography for endovascular assessment
    Unno, N
    Mitsuoka, H
    Takei, Y
    Igarashi, T
    Uchiyama, T
    Yamamoto, N
    Saito, T
    Nakamura, S
    JOURNAL OF ENDOVASCULAR THERAPY, 2002, 9 (04) : 529 - 534
  • [4] Commentary: Value of 3-Dimensional Digital Subtraction Angiography for Detection and Classification of Intracranial Aneurysm Remnants After Clipping
    Khan, Nickalus R.
    Morcos, Jacques J.
    OPERATIVE NEUROSURGERY, 2021, 21 (02) : E82 - E82
  • [5] Usefulness of 3-dimensional reconstructed images of renal arteries using rotational digital subtraction angiography
    Endo, H
    Shimizu, T
    Kodama, Y
    Miyasaka, K
    JOURNAL OF UROLOGY, 2002, 167 (05): : 2046 - 2048
  • [6] DIGITAL SUBTRACTION ANGIOGRAPHY IN DIAGNOSIS OF LEFT-VENTRICULAR ANEURYSM
    GREENBAUM, RA
    EVANS, TR
    SYMONS, C
    BRITISH HEART JOURNAL, 1983, 49 (06): : 617 - 617
  • [7] Letter: Commentary: Value of 3-Dimensional Digital Subtraction Angiography for Detection and Classification of Intracranial Aneurysm Remnants After Clipping
    Marbacher, Serge
    Steiger, Hans-Jakob
    OPERATIVE NEUROSURGERY, 2021, 21 (04) : E406 - E406
  • [8] Evaluation of a distal pericallosal artery aneurysm visualized with 3-dimensional digital subtraction angiography: case report and treatment implications
    Woodworth, GF
    McGirt, MJ
    Clatterbuck, R
    Gailloud, P
    SURGICAL NEUROLOGY, 2005, 64 (04): : 321 - 324
  • [9] In Reply: Commentary: Value of 3-Dimensional Digital Subtraction Angiography for Detection and Classification of Intracranial Aneurysm Remnants After Clipping
    Khan, Nickalus R.
    Morcos, Jacques J.
    OPERATIVE NEUROSURGERY, 2021, 21 (04) : E407 - E407
  • [10] 3-DIMENSIONAL RECONSTRUCTION OF MOVING ARTERIAL BEDS FROM DIGITAL SUBTRACTION ANGIOGRAPHY
    PARKER, DL
    POPE, DL
    VANBREE, R
    MARSHALL, HW
    COMPUTERS AND BIOMEDICAL RESEARCH, 1987, 20 (02): : 166 - 185