STUDY ON ON-SITE CALIBRATION METHOD OF STATIONARY NEUTRON DOSIMETER

被引:0
|
作者
Lv, Jinxu [1 ]
Lv, Ning [1 ]
Guo, Huiping [1 ]
Sun, Mingyan [1 ]
Zhao, Kuo [1 ]
Lv, Wenhui [1 ]
Wei, Zhihao [1 ]
Xiao, Qizhan [1 ]
Li, Daji [1 ]
Liu, Yang [2 ]
机构
[1] Xian Res Inst Hitec, Xian, Peoples R China
[2] Xian Guanneng Neutron Detect Technol Co Ltd, Xian, Peoples R China
关键词
Neutron ambient dose equivalent; Energy correction; Radiation measurement; on site calibration;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The on-site calibration system ofstationary neutron ambient dose equivalent instrument is mainly comprised of a small controllable neutron source and a reference neutron ambient dose equivalent instrument. According to the principle of "relative calibration method", a small controllable neutron source continuously emits neutrons at the calibration site to construct a neutron radiationfield. The calibration factor (NB) can be obtained by comparing the response numbers from two instrument, the instrument to be calibrated and the reference instrument, which are symmetrically placed in the neutron radiation field. In order to complete the transferofthe ambient dose equivalent calibration coefficient ofthe reference instrument from National Metrology Center (252CfStandard radiation field) to nuclearfacility site,the calibration coefficient needs to be corrected, that is, multiplied by the "energy correction coefficient". Energy correction coefficient includes: (1) "Instrument Energy Response Correction Coefficient" 1c, for neutron fluence to neutron counting of the instrument, (2) "Conversion Correction Coefficient" kp for neutron fluence to neutron ambient dose equivalent. Tests have shown that the ambient dose equivalent rate measurement error ofthe instrument which have been calibrated but without energy correction was 16.5%, by contrast the measurement error was 2.9% with energy correction. It can be seen that the energy correction is necessary and effective for the measuring instrument ofneutron ambient dose equivalent during the on-site calibration process.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] DOE PERSONNEL NEUTRON DOSIMETER INTERCOMPARISON STUDY
    FIX, JJ
    THORSON, MR
    ROBERSON, PL
    ENDRES, B
    BRACKENBUSH, LW
    FAUST, LG
    HEALTH PHYSICS, 1982, 43 (01): : 129 - 130
  • [42] Study of the On-site Calibration Technology for DC Voltage Transformer Based on Synchronous Data Acquisition
    Li Deng-yun
    Liu Jian
    Yang Chun-yan
    Xiong Qian-zhu
    Nie Qi
    PROCEEDINGS OF THE 2016 5TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2016), 2016, 98 : 112 - 117
  • [43] Method for rapid on-site identification of VOCs
    Justin D Fair
    William F Bailey
    Robert A Felty
    Amy E Gifford
    Benjamin Shultes
    Leslie H Volles
    Journal of Environmental Sciences, 2009, (07) : 1005 - 1008
  • [44] Method for the rapid on-site assessment of handleability
    Brown, Douglas W.
    Atkin, Brian P.
    Coal Preparation, 2000, 21 (03): : 299 - 313
  • [45] METHOD SPEEDS ON-SITE PRESSURE PREDICTIONS
    BOOTWALA, I
    WORLD OIL, 1979, 189 (04) : 97 - 99
  • [46] Method for rapid on-site identification of VOCs
    Justin D Fair
    William F Bailey
    Robert A Felty
    Amy E Gifford
    Benjamin Shultes
    Leslie H Volles
    Journal of Environmental Sciences, 2009, 21 (07) : 1005 - 1008
  • [47] Development of a Portable Intelligent Electric On-site Wrench Calibration Device
    Zhao, Yinming
    Xu, Jian
    Chai, Jixin
    Hao, Qun
    2020 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL, AUTOMATION AND MECHANICAL ENGINEERING, 2020, 1626
  • [48] Power Comparator Based On-Site Calibration of Isolating Current Transformers
    Mohns, Enrico
    Latzel, Hans-Georg
    Wittig, Cornelia
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2009, 24 (01): : 67 - 72
  • [49] Method for rapid on-site identification of VOCs
    Fair, Justin D.
    Bailey, William F.
    Felty, Robert A.
    Gifford, Amy E.
    Shultes, Benjamin
    Volles, Leslie H.
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2009, 21 (07) : 1005 - 1008
  • [50] AN ON-SITE CALIBRATION SYSTEM FOR ELECTRONIC INSTRUMENT TRANSFORMERS BASED ON LABVIEW
    Zhang, Ming
    Li, Kaicheng
    Wang, Jun
    He, Shunfan
    METROLOGY AND MEASUREMENT SYSTEMS, 2014, 21 (02) : 257 - 270