STUDY ON ON-SITE CALIBRATION METHOD OF STATIONARY NEUTRON DOSIMETER

被引:0
|
作者
Lv, Jinxu [1 ]
Lv, Ning [1 ]
Guo, Huiping [1 ]
Sun, Mingyan [1 ]
Zhao, Kuo [1 ]
Lv, Wenhui [1 ]
Wei, Zhihao [1 ]
Xiao, Qizhan [1 ]
Li, Daji [1 ]
Liu, Yang [2 ]
机构
[1] Xian Res Inst Hitec, Xian, Peoples R China
[2] Xian Guanneng Neutron Detect Technol Co Ltd, Xian, Peoples R China
关键词
Neutron ambient dose equivalent; Energy correction; Radiation measurement; on site calibration;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The on-site calibration system ofstationary neutron ambient dose equivalent instrument is mainly comprised of a small controllable neutron source and a reference neutron ambient dose equivalent instrument. According to the principle of "relative calibration method", a small controllable neutron source continuously emits neutrons at the calibration site to construct a neutron radiationfield. The calibration factor (NB) can be obtained by comparing the response numbers from two instrument, the instrument to be calibrated and the reference instrument, which are symmetrically placed in the neutron radiation field. In order to complete the transferofthe ambient dose equivalent calibration coefficient ofthe reference instrument from National Metrology Center (252CfStandard radiation field) to nuclearfacility site,the calibration coefficient needs to be corrected, that is, multiplied by the "energy correction coefficient". Energy correction coefficient includes: (1) "Instrument Energy Response Correction Coefficient" 1c, for neutron fluence to neutron counting of the instrument, (2) "Conversion Correction Coefficient" kp for neutron fluence to neutron ambient dose equivalent. Tests have shown that the ambient dose equivalent rate measurement error ofthe instrument which have been calibrated but without energy correction was 16.5%, by contrast the measurement error was 2.9% with energy correction. It can be seen that the energy correction is necessary and effective for the measuring instrument ofneutron ambient dose equivalent during the on-site calibration process.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] On-site calibration method for outdoor binocular stereo vision sensors
    Liu, Zhen
    Yin, Yang
    Wu, Qun
    Li, Xiaojing
    Zhang, Guangjun
    OPTICS AND LASERS IN ENGINEERING, 2016, 86 : 75 - 82
  • [2] On-site Metrology Calibration Method for River-piping Flowmeter
    Wang, Li
    Wang, Cheng
    Yang, Fei
    CIVIL ENGINEERING, ARCHITECTURE AND SUSTAINABLE INFRASTRUCTURE II, PTS 1 AND 2, 2013, 438-439 : 1294 - 1298
  • [3] Ellipse fitting method in multidimensional space for on-site sensor calibration
    Chuckpaiwong, I
    TENCON 2004 - 2004 IEEE REGION 10 CONFERENCE, VOLS A-D, PROCEEDINGS: ANALOG AND DIGITAL TECHNIQUES IN ELECTRICAL ENGINEERING, 2004, : A685 - A688
  • [4] Development of two-dimensional differential calibration method for a neutron dosimeter using a thermal neutron beam
    Matsumoto, Tetsuro
    Harano, Hideki
    Masuda, Akihiko
    Nishiyama, Jun
    Matsue, Hideaki
    Uritani, Akira
    Nunomiya, Tomoya
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 472 - 476
  • [5] Study on the method of ESDD on-site measurement
    Jiang, Xiuchen
    An, Ling
    Han, Zhendong
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2000, 20 (04): : 40 - 43
  • [6] A desktop OSL system for on-site dosimeter processing.
    Fard, R
    Hannify, R
    HEALTH PHYSICS, 2003, 84 (06): : S164 - S164
  • [7] CALIBRATION OF AN ALBEDO NEUTRON DOSIMETER FOR USE AT AN INTENSE PULSED NEUTRON FACILITY
    DOLECEK, EH
    HOWE, ML
    JOHNSON, B
    MUNDIS, RL
    HEALTH PHYSICS, 1979, 37 (06): : 843 - 844
  • [8] On-site calibration method based on stepwise solid-phase microextraction
    Xiong, GH
    Chen, Y
    Pawliszyn, J
    JOURNAL OF CHROMATOGRAPHY A, 2003, 999 (1-2) : 43 - 50
  • [9] Precise On-Site Calibration of PTZ Cameras
    Esin, Yunus Emre
    Ozdil, Omer
    Bilge, Yunus Can
    Ozturk, Safak
    32ND IEEE SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE, SIU 2024, 2024,
  • [10] On-Site Calibration of an Electric Drive: A Case Study Using a Multiphase System
    Soto-Marchena, David
    Barrero, Federico
    Colodro, Francisco
    Arahal, Manuel R.
    Mora, Jose L.
    SENSORS, 2023, 23 (17)