Comparative Study of Tritium Analysis Method with High-Volume Counting Vial

被引:1
|
作者
Yoon, Yoon Yeol [1 ,2 ]
Kim, Yongcheol [1 ]
机构
[1] Korea Inst Geosci & Mineral Resources, Geol Environm Div, Daejeon, South Korea
[2] Korea Inst Geosci & Mineral Resources, Div Geol Environm, 124 Gwahak Ro, Daejeon 34132, South Korea
来源
关键词
LSC-LB7; High Volume Vial; Tritium; UNDERGROUND WATERS;
D O I
10.14407/jrpr.2020.45.3.142
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Background: Tritium (3H) analysis in groundwater was difficult because of its low activity. Therefore, the electrolytic enrichment method was used. To improve the detection limit and for performing simple analysis, a high-volume counting vial with the available liquid scintillation counter (LSC) was investigated. Further, it was compared with a conventional 20-mL counting vial.Materials and Methods: The LSC with the electrolytic enrichment method was used 3H analy-sis in groundwater. A high-volume 145-mL counting vial was compared with a conventional 20-mL counting vial to determine the counting characteristics of different LSCs.Results and Discussion: When a Quantulus LSC was used, the counting window between channels 35 and 250 was used. The background count was approximately 1.86 cpm, and the counting efficiency increased from 8% to 40% depending on the mixing ratio of the volume of sample and cocktail solution. For LSC-LB7, the optimum counting window was between 1 and 4.9 keV, which was selected by the factory (Hitachi Aloka Medical Ltd., Japan) by considering quenching using a standard external gamma source. The background count of LSC-LB7 was ap-proximately 3.60 +/- 0.29 cpm when the 145-mL vial was used and 2.22 +/- 0.17 cpm when the 20-mL vial was used. The minimum detectable activity (MDA) of the 20-mL vial was greater for LSC-LB7 than for Quantulus. The MDA with the 145-mL vial was improved to 0.3 Bq/L when compared with the value of 1.6 Bq/L for the 20-mL vial.Conclusion: The counting efficiency when using the 145-mL vial was 27%, whereas it was 18% when using the 20-mL vial. This difference can be attributed to the vial volume. The figure of merit (FOM) of the 145-mL vial was four times greater than that of the 20-mL vial because the volume of the former vial is approximately seven times greater than that of the latter. Further, the MDA for 3H decreased from 1.6 to 0.3 Bq/L. The counting efficiency and FOM of LSC-LB7 was slightly less than those of Quantulus when the 20-mL vial was used. The background counting rate of the Quantulus was lower than that of the LSC-LB7.
引用
收藏
页码:142 / 146
页数:5
相关论文
共 50 条
  • [21] Impact of stapling devices on radical cystectomy: Comparative study between low- and high-volume surgeons
    Tzortzis, Vassilios
    Gravas, Stavros
    Mitsogiannis, Iraklis C.
    Moutzouris, Georgios
    Karatzas, Anastasios
    Leventis, Angelos
    Mpouzalas, Ioannis
    Melekos, Michael D.
    UROLOGY, 2008, 71 (02) : 337 - 340
  • [22] Online Analysis of High-Volume Data Streams in Astroparticle Physics
    Bockermann, Christian
    Bruegge, Kai
    Buss, Jens
    Egorov, Alexey
    Morik, Katharina
    Rhode, Wolfgang
    Ruhe, Tim
    MACHINE LEARNING AND KNOWLEDGE DISCOVERY IN DATABASES, PT III, 2015, 9286 : 100 - 115
  • [23] A Streamlined, High-Volume Particle Impactor for Trace Chemical Analysis
    Staymates, Matthew
    Bottiger, Jerold
    Schepers, Deborah
    Staymates, Jessica
    AEROSOL SCIENCE AND TECHNOLOGY, 2013, 47 (09) : 945 - 954
  • [24] High-volume quantitative analysis in the clinical mass spectrometry laboratory
    Alexander, MS
    LC GC-MAGAZINE OF SEPARATION SCIENCE, 1995, 13 (04): : 338 - 338
  • [25] Design of an integrated system for rapid, high-volume soil analysis
    Baliteau, JY
    ANALUSIS, 1997, 25 (9-10) : M39 - M41
  • [26] Analysis of Otolaryngologic Readmissions at a High-Volume Quaternary Referral Center
    Godse, Neal R.
    Snyderman, Carl H.
    LARYNGOSCOPE, 2023, 133 (10): : 2546 - 2552
  • [27] Derivation of flow rate and calibration method for high-volume air samplers
    Hann, Richard
    Hermanson, Mark
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2019, 12 (09) : 4725 - 4731
  • [28] Not-so-simple nephrectomy: Comparative analysis of radical and simple nephrectomy in a high-volume tertiary referral center
    Bhat, Gajanan Shripad
    INTERNATIONAL JOURNAL OF UROLOGY, 2023,
  • [29] PRODUCTION SCHEDULING FOR HIGH-VOLUME ASSEMBLIES - A CASE-STUDY
    FISK, JC
    SOLANO, A
    JOURNAL OF THE OPERATIONAL RESEARCH SOCIETY, 1980, 31 (09) : 781 - 789
  • [30] Not-so-simple nephrectomy: Comparative analysis of radical and simple nephrectomy in a high-volume tertiary referral center
    Papadopoulou, Ariadni
    Campain, Nicholas
    Abu-Ghanem, Yasmin
    Shanmugathas, Nimlan
    Poullas, Marios
    Mumtaz, Faiz
    Barod, Ravi
    Tran, Maxine
    Bex, Axel
    Patki, Prasad
    INTERNATIONAL JOURNAL OF UROLOGY, 2023, : 160 - 168