Comparative Study of Tritium Analysis Method with High-Volume Counting Vial

被引:1
|
作者
Yoon, Yoon Yeol [1 ,2 ]
Kim, Yongcheol [1 ]
机构
[1] Korea Inst Geosci & Mineral Resources, Geol Environm Div, Daejeon, South Korea
[2] Korea Inst Geosci & Mineral Resources, Div Geol Environm, 124 Gwahak Ro, Daejeon 34132, South Korea
来源
关键词
LSC-LB7; High Volume Vial; Tritium; UNDERGROUND WATERS;
D O I
10.14407/jrpr.2020.45.3.142
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Background: Tritium (3H) analysis in groundwater was difficult because of its low activity. Therefore, the electrolytic enrichment method was used. To improve the detection limit and for performing simple analysis, a high-volume counting vial with the available liquid scintillation counter (LSC) was investigated. Further, it was compared with a conventional 20-mL counting vial.Materials and Methods: The LSC with the electrolytic enrichment method was used 3H analy-sis in groundwater. A high-volume 145-mL counting vial was compared with a conventional 20-mL counting vial to determine the counting characteristics of different LSCs.Results and Discussion: When a Quantulus LSC was used, the counting window between channels 35 and 250 was used. The background count was approximately 1.86 cpm, and the counting efficiency increased from 8% to 40% depending on the mixing ratio of the volume of sample and cocktail solution. For LSC-LB7, the optimum counting window was between 1 and 4.9 keV, which was selected by the factory (Hitachi Aloka Medical Ltd., Japan) by considering quenching using a standard external gamma source. The background count of LSC-LB7 was ap-proximately 3.60 +/- 0.29 cpm when the 145-mL vial was used and 2.22 +/- 0.17 cpm when the 20-mL vial was used. The minimum detectable activity (MDA) of the 20-mL vial was greater for LSC-LB7 than for Quantulus. The MDA with the 145-mL vial was improved to 0.3 Bq/L when compared with the value of 1.6 Bq/L for the 20-mL vial.Conclusion: The counting efficiency when using the 145-mL vial was 27%, whereas it was 18% when using the 20-mL vial. This difference can be attributed to the vial volume. The figure of merit (FOM) of the 145-mL vial was four times greater than that of the 20-mL vial because the volume of the former vial is approximately seven times greater than that of the latter. Further, the MDA for 3H decreased from 1.6 to 0.3 Bq/L. The counting efficiency and FOM of LSC-LB7 was slightly less than those of Quantulus when the 20-mL vial was used. The background counting rate of the Quantulus was lower than that of the LSC-LB7.
引用
收藏
页码:142 / 146
页数:5
相关论文
共 50 条
  • [11] Comparative study of laparoscopic versus open radical gastrectomy in advanced gastric neuroendocrine carcinoma: Analysis from a high-volume institution
    Zhao, Ya-Jun
    Zhuang, Lv-Ping
    Liu, Yi-Yang
    Chen, Ren-Cheng
    Zhang, Jun
    Zhu, Hai-Xing
    Wang, Yong-Cang
    You, Hao
    Zhang, Ming-Wei
    He, Xin-Yang
    ASIAN JOURNAL OF SURGERY, 2020, 43 (03) : 488 - 496
  • [12] High-Volume Fly Ash Concrete: Analysis and Application
    Reiner, Mark
    Rens, Kevin
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2006, 11 (01) : 58 - 64
  • [13] Study on measurement and comparative analysis of tritium water and total tritium in urine
    Wang, Lan-Xin
    Zhang, Tai-Ming
    Ruan, Guang-Lin
    Liu, Xue-Jun
    Luo, Ning
    He-Huaxue yu Fangshe Huaxue/Journal of Nuclear and Radiochemistry, 2003, 25 (04):
  • [14] HIGH-VOLUME CRYSTALLOID CARDIOPLEGIA - AN IMPROVED METHOD OF MYOCARDIAL PRESERVATION
    ENGELMAN, RM
    ROUSOU, JH
    LEMESHOW, S
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1983, 86 (01): : 87 - 96
  • [15] Study on analysis method of tritium in seawater
    Zeng Xianzhang
    accepted October 4
    ActaOceanologicaSinica, 1991, (02) : 237 - 248
  • [16] A comparative profitability analysis of transcatheter versus surgical aortic valve replacement in a high-volume French hospital
    Huchet, Francois
    Chan-Peng, Jacques
    d'Acremont, Fanny
    Guerin, Patrice
    Grimandi, Gael
    Roussel, Jean-Christian
    Plessis, Julien
    Letocart, Vincent
    Senage, Thomas
    Manigold, Thibaut
    HEALTH ECONOMICS REVIEW, 2019, 9 (1)
  • [17] A comparative profitability analysis of transcatheter versus surgical aortic valve replacement in a high-volume French hospital
    François Huchet
    Jacques Chan-Peng
    Fanny d’Acremont
    Patrice Guerin
    Gael Grimandi
    Jean-Christian Roussel
    Julien Plessis
    Vincent Letocart
    Thomas Senage
    Thibaut Manigold
    Health Economics Review, 9
  • [18] A comparative study of the bond strength of reinforcing steel in high-volume fly ash concrete and conventional concrete
    Arezoumandi, Mahdi
    Wolfe, Michael H.
    Volz, Jeffery S.
    CONSTRUCTION AND BUILDING MATERIALS, 2013, 40 : 919 - 924
  • [19] A comparative study of the mechanical properties, fracture behavior, creep, and shrinkage of high-volume fly ash concrete
    Arezoumandi, Mahdi
    Volz, Jeffery S.
    JOURNAL OF SUSTAINABLE CEMENT-BASED MATERIALS, 2013, 2 (3-4) : 173 - 185
  • [20] Quantile Coarsening Analysis of High-Volume Wearable Activity Data in a Longitudinal Observational Study
    Cheung, Ying Kuen
    Hsueh, Pei-Yun Sabrina
    Ensari, Ipek
    Willey, Joshua Z.
    Diaz, Keith M.
    SENSORS, 2018, 18 (09)