Surface modification of SU-8 by photografting of functional polymers for lab-on-a-chip applications

被引:0
|
作者
Gao, Zhan [1 ]
Henthorn, David B. [1 ]
Kim, Chang-Soo [2 ]
机构
[1] Univ Missouri, Dept Chem & Biol Engn, Rolla, MO 65401 USA
[2] Univ Missouri, Dept Elect & Comp Engn & Biol Sci, Rolla, MO 65401 USA
基金
美国国家科学基金会;
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Due to the high flexibility and versatility in the process development of microfluidic devices, an epoxy-based, high-aspect ratio photoresist SU-8 is now attracting attention as the main structuring material of the fluidic channels. Manipulation of the surface properties of SU-8 channel wall is critical to attach functional films such as enzyme-immobilized layers or biocompatible layers. We describe a new in situ patterning method to form a hydrogel film on SU-8 by a photografted polymerization procedure. The hydrophobic surface of SU-8 is modified using a surface bound initiator HCPK (1-hydroxycyclohexyl phenyl ketone). A p-HEMA (poly-2-hydroxyethylmethacrylate) hydrogel film is grafted by photopolymerization of solution-phase precursors on the modified surface. The contact angle measurements reveal that the hydrophilicity was increased after the grafting. This is a promising in situ formation method of patterned functional films within a completed microfluidic channel.
引用
收藏
页码:121 / +
页数:2
相关论文
共 50 条
  • [41] On-chip liquid storage and dispensing for lab-on-a-chip applications
    Boden, Roger
    Lehto, Marcus
    Margell, Joakim
    Hjort, Klas
    Schweitz, Jan-Ake
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2008, 18 (07)
  • [42] SU-8 thick photoresist processing as a functional material for MEMS applications
    Conradie, EH
    Moore, DF
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2002, 12 (04) : 368 - 374
  • [43] Surface graft polymerization of SU-8 for bio-MEMS applications
    Wang, Yuli
    Pai, Jeng-Hao
    Lai, Hsuan-Hong
    Sims, Christopher E.
    Bachman, Mark
    Li, G. P.
    Allbritton, Nancy L.
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2007, 17 (07) : 1371 - 1380
  • [44] Heterogeneously integrated optical system for lab-on-a-chip applications
    Song, Fuchuan
    Xiao, Jing
    Seo, Sang-Woo
    SENSORS AND ACTUATORS A-PHYSICAL, 2013, 195 : 148 - 153
  • [45] 3D nanomolding for lab-on-a-chip applications
    Farshchian, Bahador
    Park, Sooyeon
    Choi, Junseo
    Amirsadeghi, Alborz
    Lee, Jaejong
    Park, Sunggook
    LAB ON A CHIP, 2012, 12 (22) : 4764 - 4771
  • [46] Microfluidic lab-on-a-chip systems based on polymers - fabrication and application
    Guber, A.E. (andreas.guber@imt.fzk.de), 1600, Elsevier (101): : 1 - 3
  • [47] A programmable planar electroosmotic micropump for lab-on-a-chip applications
    Seibel, Konstantin
    Schoeler, Lars
    Schaefer, Heiko
    Boehm, Markus
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2008, 18 (02)
  • [48] MICROFLUIDIC LAB-ON-A-CHIP PLATFORMS: REQUIREMENTS, CHARACTERISTICS AND APPLICATIONS
    Mark, D.
    Haeberle, S.
    Roth, G.
    Von Stetten, F.
    Zengerle, R.
    MICROFLUIDICS BASED MICROSYSTEMS: FUNDAMENTALS AND APPLICATIONS, 2010, : 305 - 376
  • [49] An integrated fluorescence detection system for lab-on-a-chip applications
    Novak, Lukas
    Neuzil, Pavel
    Pipper, Juergen
    Zhang, Yi
    Lee, Shinhan
    LAB ON A CHIP, 2007, 7 (01) : 27 - 29
  • [50] Lab-on-a-chip device made by autohesion-bonded polymers
    Awaja, Firas
    Wong, Tsz-ting
    Arhatari, Benedicta
    BIOMEDICAL MICRODEVICES, 2017, 20 (01)