Effects of orthodontic mini-implant position in the dragon helix appliance on tooth displacement and stress distribution: a three-dimensional finite element analysis

被引:6
|
作者
Kim, Min-Ji [1 ]
Park, Sun-Hyung [2 ]
Kim, Hyeon-Seong [3 ]
Mo, Sung-Seo [4 ]
Sung, Sang-Jin [5 ]
Jang, Gang-Won [6 ]
Chun, Youn-Sic [1 ]
机构
[1] Ewha Womans Univ, Dept Dent, Sch Med, Div Orthodont, Seoul 158710, South Korea
[2] Univ Nebraska Med Ctr, Div Orthodont, Dept Dent, Omaha, NE USA
[3] Ewha Womans Univ, Grad Sch Clin Dent, Dept Orthodont, Seoul 158710, South Korea
[4] Catholic Univ Korea, Div Orthodont, Dept Dent, Coll Med,St Marys Hosp, Seoul, South Korea
[5] Univ Ulsan, Coll Med, Dept Orthodont, Asan Med Ctr, Ulsan, South Korea
[6] Kunsan Natl Univ, Sch Mech & Automobile Engn, Kunsan, South Korea
关键词
Orthodontic mini-implant; FEM; INTRUSION; MOLARS; BONE;
D O I
10.4041/kjod.2011.41.3.191
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The purpose of this study was to investigate the stress distribution on the orthodontic mini-implant (OMI) surface and periodontal ligament of the maxillary first and second molars as well as the tooth displacement according to the OMI position in the dragon helix appliance during scissors-bite correction. Methods: OMIs were placed at two maxillary positions, between the first and the second premolars (group 1) and between the second premolar and the first molar (group 2). The stress distribution area (SDA) was analyzed by three-dimensional finite element analysis. Results: The maximal SDA of the OMI did not differ between the groups. It was located at the cervical area and palatal root apex of the maxillary first molar in groups 1 and 2, respectively, indicating less tipping in group 2. The minimal SDA was located at the root and furcation area of the maxillary second molar in groups 1 and 2, respectively, indicating greater palatal crown displacement in group 2. Conclusions: Placement of the OMI between the maxillary second premolar and the maxillary first molar to serve as an indirect anchor in the dragon helix appliance minimizes anchorage loss while maximizing the effect on scissors-bite correction. (Korean J Orthod 2011; 41(3):191-199)
引用
收藏
页码:191 / 199
页数:9
相关论文
共 50 条
  • [31] Three-Dimensional Finite Element Analysis on Stress Distribution of Internal Implant-Abutment Engagement Features
    Cho, Sung-Yong
    Huh, Yun-Hyuk
    Park, Chan-Jin
    Cho, Lee-Ra
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (02) : 319 - 327
  • [32] Three-dimensional finite element analysis of strength, stability, and stress distribution in orthodontic anchorage: A conical, self-drilling miniscrew implant system
    Singh, Shivani
    Mogra, Subraya
    Shetty, V. Surendra
    Shetty, Siddarth
    Philip, Pramod
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 141 (03) : 327 - 336
  • [33] Three-dimensional finite element stress and strain analysis of a transfemoral osseointegration implant
    Xu, Wei
    Xu, Dong Hao
    Crocombe, A. D.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H6) : 661 - 670
  • [34] Three-dimensional finite element stress analysis of a cuneiform-geometry implant
    Cruz, M
    Wassall, T
    Toledo, EM
    Barra, LPD
    Lemonge, ACD
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (05) : 675 - 684
  • [35] Stress Analysis of Dental Implant Bodies by Three-Dimensional Finite Element Method
    Kageyama, Yoshiyuki
    Shimura, Mari
    Nagai, Eiichi
    Sato, Yoshinori
    Majima, Hideyuki
    Journal of Robotics and Mechatronics, 1995, 7 (02): : 169 - 171
  • [36] Influence of prosthetic index structures and implant materials on stress distribution in implant restorations: a three-dimensional finite element analysis
    Anniwaer, Annikaer
    Muhetaer, Aihemaiti
    Yin, Zhengrong
    Zhu, Jiakang
    Jin, Chunxiao
    Huang, Cui
    BMC ORAL HEALTH, 2024, 24 (01):
  • [37] Three-dimensional digital imaging analysis of the palatal bone thickness for orthodontic mini-implant insertion - determination of the safe zone and angulation
    Schubert, Hanna
    Matta, Ragai
    Seidel, Anna
    Adler, Werner
    Wichmann, Manfred
    Kesting, Marco
    Lutz, Rainer
    BMC ORAL HEALTH, 2024, 24 (01):
  • [38] Stress distribution in delayed replanted teeth splinted with different orthodontic wires: a three-dimensional finite element analysis
    de Souza, Fernando Isquierdo
    Poi, Wilson Roberto
    da Silva, Vanessa Ferreira
    Martini, Ana Paula
    da Cunha Melo, Regis Alexandre
    Panzarini, Sonia Regina
    Rocha, Eduardo Passos
    DENTAL TRAUMATOLOGY, 2015, 31 (03) : 190 - 195
  • [39] Three-dimensional finite element analysis comparative model of tooth-implant nonrigid fixation
    Muradyan, Tigran A.
    Muradyan, Nshan A.
    Verlinski, Sergey V.
    Poghosyan, Anna Yu
    SIMULATION-TRANSACTIONS OF THE SOCIETY FOR MODELING AND SIMULATION INTERNATIONAL, 2021, 97 (04): : 239 - 246
  • [40] TOOTH DISPLACEMENT IN SHORTENED DENTAL ARCHES: A THREE-DIMENSIONAL FINITE ELEMENT STUDY
    De Oliveira, Bruno Franco
    Seraidarian, Paulo Isaias
    de Oliveira, Sergio Gomes
    Landre, Janes, Jr.
    Pithon, Matheus Melo
    Oliveira, Dauro Douglas
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (06): : 460 - 465