Effects of orthodontic mini-implant position in the dragon helix appliance on tooth displacement and stress distribution: a three-dimensional finite element analysis

被引:6
|
作者
Kim, Min-Ji [1 ]
Park, Sun-Hyung [2 ]
Kim, Hyeon-Seong [3 ]
Mo, Sung-Seo [4 ]
Sung, Sang-Jin [5 ]
Jang, Gang-Won [6 ]
Chun, Youn-Sic [1 ]
机构
[1] Ewha Womans Univ, Dept Dent, Sch Med, Div Orthodont, Seoul 158710, South Korea
[2] Univ Nebraska Med Ctr, Div Orthodont, Dept Dent, Omaha, NE USA
[3] Ewha Womans Univ, Grad Sch Clin Dent, Dept Orthodont, Seoul 158710, South Korea
[4] Catholic Univ Korea, Div Orthodont, Dept Dent, Coll Med,St Marys Hosp, Seoul, South Korea
[5] Univ Ulsan, Coll Med, Dept Orthodont, Asan Med Ctr, Ulsan, South Korea
[6] Kunsan Natl Univ, Sch Mech & Automobile Engn, Kunsan, South Korea
关键词
Orthodontic mini-implant; FEM; INTRUSION; MOLARS; BONE;
D O I
10.4041/kjod.2011.41.3.191
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The purpose of this study was to investigate the stress distribution on the orthodontic mini-implant (OMI) surface and periodontal ligament of the maxillary first and second molars as well as the tooth displacement according to the OMI position in the dragon helix appliance during scissors-bite correction. Methods: OMIs were placed at two maxillary positions, between the first and the second premolars (group 1) and between the second premolar and the first molar (group 2). The stress distribution area (SDA) was analyzed by three-dimensional finite element analysis. Results: The maximal SDA of the OMI did not differ between the groups. It was located at the cervical area and palatal root apex of the maxillary first molar in groups 1 and 2, respectively, indicating less tipping in group 2. The minimal SDA was located at the root and furcation area of the maxillary second molar in groups 1 and 2, respectively, indicating greater palatal crown displacement in group 2. Conclusions: Placement of the OMI between the maxillary second premolar and the maxillary first molar to serve as an indirect anchor in the dragon helix appliance minimizes anchorage loss while maximizing the effect on scissors-bite correction. (Korean J Orthod 2011; 41(3):191-199)
引用
收藏
页码:191 / 199
页数:9
相关论文
共 50 条
  • [21] Stress distribution of the variable dynamic loading in the dental implant: A three-dimensional finite element analysis
    Djebbar N.
    Serier B.
    Bouiadjra B.B.
    1600, Trans Tech Publications Ltd (31): : 44 - 52
  • [22] Stress distribution of two commercial dental implant systems: A three-dimensional finite element analysis
    Chang, Hao-Sheng
    Chen, Yi-Chin
    Hsieh, Yao-Dung
    Hsu, Ming-Lun
    JOURNAL OF DENTAL SCIENCES, 2013, 8 (03) : 261 - 271
  • [23] Three-Dimensional Finite Element Analysis of the Stress Distribution at the Internal Implant-Abutment Connection
    Cho, Sung-Yong
    Huh, Yoon-Hyuk
    Park, Chan-Jin
    Cho, Lee-Ra
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2016, 36 (03) : E49 - E58
  • [24] Effect of Offset Implant Placement on the Stress Distribution Around a Dental Implant: A Three-Dimensional Finite Element Analysis
    Siadat, Hakimeh
    Hashemzadeh, Shervin
    Geramy, Allahyar
    Bassir, Seyed Hossein
    Alikhasi, Marzieh
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (06) : 646 - 651
  • [25] Analysis for Predictors of Failure of Orthodontic Mini-implant Using Patient-Specific Finite Element Models
    Takahiro Toriya
    Toru Kitahara
    Hiroto Hyakutake
    Mitsugu Todo
    Ichiro Takahashi
    Annals of Biomedical Engineering, 2023, 51 : 594 - 603
  • [26] The effect of implant number and position on the stress behavior of mandibular implant retained overdentures: A three-dimensional finite element analysis
    Topkaya, Tolga
    Solmaz, Murat Yavuz
    JOURNAL OF BIOMECHANICS, 2015, 48 (10) : 2102 - 2109
  • [27] Stress Distribution in Obliquely Inserted Orthodontic Miniscrews Evaluated by Three-Dimensional Finite-Element Analysis
    Kuroda, Shingo
    Inoue, Masahide
    Kyung, Hee-Moon
    Koolstra, Jan Harm
    Tanaka, Eiji
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (02) : 344 - 349
  • [28] Effective en-masse retraction design with orthodontic mini-implant anchorage: A finite element analysis
    Sung, Sang-Jin
    Jang, Gang-Won
    Chun, Youn-Sic
    Moon, Yoon-Shik
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (05) : 648 - 657
  • [29] Analysis for Predictors of Failure of Orthodontic Mini-implant Using Patient-Specific Finite Element Models
    Toriya, Takahiro
    Kitahara, Toru
    Hyakutake, Hiroto
    Todo, Mitsugu
    Takahashi, Ichiro
    ANNALS OF BIOMEDICAL ENGINEERING, 2023, 51 (03) : 594 - 603
  • [30] Evaluation of Stress Pattern Caused by Mini-Implant in Mandibular Alveolar Bone with Different Angulations and Retraction Forces: A Three-Dimensional Finite Element Study
    Sidhu, Manreet
    Chugh, Vinay Kumar
    Dmello, Kuldeep
    Mehta, Anurag
    Chugh, Ankita
    Tandon, Pradeep
    TURKISH JOURNAL OF ORTHODONTICS, 2020, 33 (03) : 150 - 156