Investigation of Application-Specific Bias Conditions and Dose Rate Dependency in Total Ionizing Dose (TID) Response

被引:0
|
作者
Bozovich, Amanda N. [1 ,2 ]
Duc Nguyen [2 ]
Rax, Bernard G. [2 ]
Davila, Joe [2 ]
Zajac, Stephanie A. [2 ]
机构
[1] CALTECH, Jet Prop Lab, NASA, 4800 Oak Grove Dr, Pasadena, CA 91109 USA
[2] CALTECH, Jet Prop Lab, 4800 Oak Grove Dr, Pasadena, CA 91109 USA
关键词
D O I
10.1109/REDW51883.2020.9325830
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
This paper investigates flight circuit application bias and irradiation dose rate dependencies ("test as you fly" conditions) in the total ionizing dose (TID) response of various electronic components considered for use in a space radiation environment.
引用
收藏
页码:13 / 18
页数:6
相关论文
共 50 条
  • [21] Total ionizing dose hardness assurance issues for high dose rate environments
    Schwank, J. R.
    Sexton, F. W.
    Shaneyfelt, M. R.
    Fleetwood, D. M.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (04) : 1042 - 1048
  • [22] Total ionizing dose (TID) evaluation of magnetic tunnel junction (MTJ) current sensors
    Ravelo Arias, Sergio Ivan
    Ramirez Munoz, Diego
    Cardoso, Susana
    Ferreira, Ricardo
    Peixeiro de Freitas, Paulo Jorge
    SENSORS AND ACTUATORS A-PHYSICAL, 2015, 225 : 119 - 127
  • [23] Impact of Bias Conditions on Total Ionizing Dose Effects of 60Coγ in SiGe HBT
    Zhang, Jinxin
    Guo, Qi
    Guo, Hongxia
    Lu, Wu
    He, Chaohui
    Wang, Xin
    Li, Pei
    Liu, Mohan
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (02) : 1251 - 1258
  • [24] Updated Compendium of Total Ionizing Dose (TID) Test Results for the Europa Clipper Mission
    Zajac, Stephanie A.
    Bozovich, Amanda N.
    Rax, Bernard G.
    Davila, Joe
    Duc Nguyen
    Parker, Wilson P.
    Kenna, Aaron J.
    McClure, Steven S.
    Thomas, Jason L.
    Stanford, Kelly W.
    Sundgaard, Mitch J.
    2020 IEEE RADIATION EFFECTS DATA WORKSHOP (IN CONJUNCTION WITH 2020 NSREC), 2020, : 27 - 30
  • [25] The Susceptibility of TaOx-Based Memristors to High Dose Rate Ionizing Radiation and Total Ionizing Dose
    McLain, Michael L.
    Hjalmarson, Harold P.
    Sheridan, Tim J.
    Mickel, Patrick R.
    Hanson, Don
    McDonald, Kyle
    Hughart, David R.
    Marine, Matthew J.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (06) : 2997 - 3004
  • [26] Total Ionizing Dose Response and Annealing Behavior of Bulk nFinFETs With ON-State Bias Irradiation
    Yang, Ling
    Zhang, Qingzhu
    Huang, Yunbo
    Zheng, Zhongshan
    Li, Bo
    Li, Binhong
    Zhang, Xingyao
    Zhu, Huiping
    Yin, Huaxiang
    Guo, Qi
    Luo, Jiajun
    Han, Zhengsheng
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2018, 65 (08) : 1503 - 1510
  • [27] Investigation of Dose Rate and TID Effects in Anisotropic Magneto Resistive Sensor
    Grebenkina, A. V.
    Boychenko, D. V.
    Nikiforov, A. Y.
    Telets, V. A.
    Amelichev, V. V.
    Kharitonov, V. A.
    2014 29TH INTERNATIONAL CONFERENCE ON MICROELECTRONICS PROCEEDINGS - MIEL 2014, 2014, : 133 - 135
  • [28] Investigation of the dose rate dependency of the PAGAT gel dosimeter at low dose rates
    Zehtabian, M.
    Faghihi, R.
    Zahmatkesh, M. H.
    Meigooni, A. S.
    Mosleh-Shirazi, M. A.
    Mehdizadeh, S.
    Sina, S.
    Bagheri, S.
    RADIATION MEASUREMENTS, 2012, 47 (02) : 139 - 144
  • [29] Displacement Damage and Total Ionizing Dose at High and Low Dose Rate Performance of an Optocoupler
    Yang, Z. -W.
    Hiemstra, D. M.
    Shi, S.
    Jin, C.
    Li, Z. -R.
    Chen, L.
    2022 IEEE RADIATION EFFECTS DATA WORKSHOP (REDW) (IN CONJUNCTION WITH 2022 NSREC), 2022, : 157 - 161
  • [30] Total Ionizing Dose (TID) Effects on Finger Transistors in a 65nm CMOS Process
    Jiang, Jize
    Shu, Wei
    Chong, Kwen-Siong
    Lin, Tong
    Lwin, Ne Kyaw Zwa
    Chang, Joseph S.
    Liu, Jingyuan