WEAR OF CERAMIC AND TITANIUM BALL ATTACHMENTS IN SUBJECTS WITH AN IMPLANT-RETAINED OVERDENTURE: A CONTROLLED CLINICAL TRIAL

被引:1
|
作者
Buettel, Adrian E. [1 ]
Luethy, Heinz [2 ]
Sendi, Pedram [1 ]
Marinello, Carlo P. [1 ]
机构
[1] Univ Basel, Sch Dent, Clin Reconstruct Dent & Temporomandibular Disorde, CH-4056 Basel, Switzerland
[2] Univ Basel, Sch Dent, Inst Mat Sci, CH-4056 Basel, Switzerland
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2012年 / 107卷 / 02期
关键词
ELECTROPLATED GOLD COPINGS; MANDIBULAR OVERDENTURES; PATIENT SATISFACTION; TELESCOPIC RETAINER; EDENTULOUS PATIENTS; REMOVABLE DENTURES;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Loss of retention of implant-retained overdentures due to wear of the patrix or matrix of the attachment system is a common clinical problem. Purpose. The purpose of this controlled clinical trial was to compare the wear of ceramic and titanium ball attachments and their corresponding gold matrices after 1 year of clinical function in subjects with implant-retained mandibular overdentures. Material and methods. Forty subjects who had been treated with a 2-implant-retained overdenture received either 2 ruby ball attachments (20 subjects) or 2 titanium ball attachments (20 subjects). The diameter of the ball attachments and the thickness of the matrix were measured optically before insertion and after 1 year of clinical function. Differences among groups were then compared with the Wilcoxon rank sum test (alpha=.05). To estimate any correlation between clinical parameters and wear, the Spearman rank test was used. Results. There was no significant difference (P=.73) in the median wear of ball attachments for the titanium group (5.3 mu m; median 1.3 mu m) and for the ceramic group (1.3 mu m; median 1.3 mu m). In the ceramic group, a fracture rate of 30% was observed. The mean wear of the matrices in the titanium group was 3.1 mu m (median 6.8 mu m) and in the ceramic group 2.1 mu m (median 3.4 mu m), P=.01. No correlation was found between ball attachment wear and matrix insert wear (Spearman rank test). Wear of matrices was weakly correlated with an increase in divergence between implant axes in the sagittal plane (P=-.28 and P=.021). Ball attachment wear was associated with an increase in divergence between matrix axes in the sagittal plane (P=-.34 and P=.047). Conclusions. Matrices on ceramic ball attachments showed less wear than those placed on titanium ball attachments. However, the use of ruby ball attachments cannot be recommended because of a high fracture rate. (J Prosthet Dent 2012;107:109-113)
引用
收藏
页码:109 / 113
页数:5
相关论文
共 50 条
  • [41] Evaluation of volumetric wear of abutments on the retention loss of ball attachment systems in implant-retained overdentures: An in vitro study
    Yabul, Ali
    Dayan, Cagatay
    Geckili, Onur
    Bilhan, Hakan
    Tuncer, Necat
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (05) : 778 - 784
  • [42] Can nocturnal use of implant-retained overdenture improve cardiorespiratory stability of a patient with obstructive sleep apnea? A clinical report
    Piskin, Bulent
    Uyar, Alper
    Senel, Bugra
    Avsever, Hakan
    Karakoc, Omer
    Tasci, Canturk
    Bayar, Gurkan Rasit
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (06): : 706 - 708
  • [43] Patient satisfaction and crestal bone changes with one-piece and two-piece single implant-retained mandibular overdenture: A randomized controlled clinical study
    Singh, Swati
    Mishra, Sunil Kumar
    Chowdhary, Ramesh
    JOURNAL OF PROSTHODONTIC RESEARCH, 2023, 67 (01) : 112 - 120
  • [44] A controlled clinical trial of implant-retained mandibular overdentures: 10 years' results of clinical aspects and aftercare of IMZ implants and Branemark implants
    Meijer, HJA
    Raghoebar, GM
    Van't Hof, MA
    Visser, A
    CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) : 421 - 427
  • [45] Effect of Ball and Bar Attachment Type on Patient Satisfaction Using Two-Implant-Retained Mandibular Overdenture: A Crossover Randomized Clinical Trial
    Deshpande, Saee
    Chandak, Anuj
    Radke, Usha
    Mahalle, Hienna
    Patil, Pravinkumar G.
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2022, 21 (04): : 1175 - 1179
  • [46] Effect of Ball and Bar Attachment Type on Patient Satisfaction Using Two-Implant-Retained Mandibular Overdenture: A Crossover Randomized Clinical Trial
    Saee Deshpande
    Anuj Chandak
    Usha Radke
    Hienna Mahalle
    Pravinkumar G. Patil
    Journal of Maxillofacial and Oral Surgery, 2022, 21 : 1175 - 1179
  • [47] Maxillary implant overdenture retained by four unsplinted attachments and opposed by a natural or fixed dentition: One-year clinical outcomes
    Bouhy, Alice
    Rompen, Eric
    Lamy, Marc
    Legros, Caroline
    Lecloux, Geoffrey
    Lambert, France
    CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (08) : 747 - 767
  • [48] Clinical aspects of a multicenter clinical trial of implant-retained mandibular overdentures in patients with severely resorbed mandibles
    Geertman, ME
    Boerrigter, EM
    VanWaas, MAJ
    vanOort, RP
    JOURNAL OF PROSTHETIC DENTISTRY, 1996, 75 (02): : 194 - 204
  • [49] A MULTICENTER RANDOMIZED CLINICAL-TRIAL OF IMPLANT-RETAINED MANDIBULAR OVERDENTURES - METHODOLOGY AND CHEWING ABILITY
    GEERTMAN, ME
    BOERRIGTER, EM
    VANWAAS, MAJ
    KALK, W
    JOURNAL OF DENTAL RESEARCH, 1994, 73 : 217 - 217
  • [50] A MULTICENTER CLINICAL-TRIAL OF IMPLANT-RETAINED MANDIBULAR OVERDENTURES IN PATIENTS WITH SEVERELY RESORBED MANDIBLES - CLINICAL ASPECTS
    GEERTMAN, ME
    BOERRIGTER, EM
    VANWAAS, MAJ
    KALK, W
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 532 - 532