WEAR OF CERAMIC AND TITANIUM BALL ATTACHMENTS IN SUBJECTS WITH AN IMPLANT-RETAINED OVERDENTURE: A CONTROLLED CLINICAL TRIAL

被引:1
|
作者
Buettel, Adrian E. [1 ]
Luethy, Heinz [2 ]
Sendi, Pedram [1 ]
Marinello, Carlo P. [1 ]
机构
[1] Univ Basel, Sch Dent, Clin Reconstruct Dent & Temporomandibular Disorde, CH-4056 Basel, Switzerland
[2] Univ Basel, Sch Dent, Inst Mat Sci, CH-4056 Basel, Switzerland
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2012年 / 107卷 / 02期
关键词
ELECTROPLATED GOLD COPINGS; MANDIBULAR OVERDENTURES; PATIENT SATISFACTION; TELESCOPIC RETAINER; EDENTULOUS PATIENTS; REMOVABLE DENTURES;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Loss of retention of implant-retained overdentures due to wear of the patrix or matrix of the attachment system is a common clinical problem. Purpose. The purpose of this controlled clinical trial was to compare the wear of ceramic and titanium ball attachments and their corresponding gold matrices after 1 year of clinical function in subjects with implant-retained mandibular overdentures. Material and methods. Forty subjects who had been treated with a 2-implant-retained overdenture received either 2 ruby ball attachments (20 subjects) or 2 titanium ball attachments (20 subjects). The diameter of the ball attachments and the thickness of the matrix were measured optically before insertion and after 1 year of clinical function. Differences among groups were then compared with the Wilcoxon rank sum test (alpha=.05). To estimate any correlation between clinical parameters and wear, the Spearman rank test was used. Results. There was no significant difference (P=.73) in the median wear of ball attachments for the titanium group (5.3 mu m; median 1.3 mu m) and for the ceramic group (1.3 mu m; median 1.3 mu m). In the ceramic group, a fracture rate of 30% was observed. The mean wear of the matrices in the titanium group was 3.1 mu m (median 6.8 mu m) and in the ceramic group 2.1 mu m (median 3.4 mu m), P=.01. No correlation was found between ball attachment wear and matrix insert wear (Spearman rank test). Wear of matrices was weakly correlated with an increase in divergence between implant axes in the sagittal plane (P=-.28 and P=.021). Ball attachment wear was associated with an increase in divergence between matrix axes in the sagittal plane (P=-.34 and P=.047). Conclusions. Matrices on ceramic ball attachments showed less wear than those placed on titanium ball attachments. However, the use of ruby ball attachments cannot be recommended because of a high fracture rate. (J Prosthet Dent 2012;107:109-113)
引用
收藏
页码:109 / 113
页数:5
相关论文
共 50 条
  • [21] Ball versus other attachments in mini implant retained overdenture: a systematic review and meta-analysis
    Zin Hnin Pwint Aung
    Pyae Phyo Win
    Thanapat Sastraruji
    Pathawee Khongkhunthian
    BMC Oral Health, 25 (1)
  • [22] The 2-Visit CAD-CAM Implant-Retained Overdenture: A Clinical Report
    Bidra, Avinash S.
    JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (06) : 722 - 728
  • [23] Reconstruction of Gingival Mask around CAD-CAM Bar and Ball Attachment in Implant-Retained Overdenture
    Atashi, Samira Naybandi
    Zeighami, Somayeh
    CASE REPORTS IN DENTISTRY, 2024, 2024
  • [24] Bar versus ball attachments for maxillary four-implant retained overdentures: A randomized controlled trial
    Park, Jin-Hong
    Shin, Sang-Wan
    Lee, Jeong-Yol
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (11) : 1076 - 1084
  • [25] Implant-retained overdenture using self-aligning and short profile attachments and palateless maxillary denture: a case report
    Al-Adl, A. Z.
    Fayyad, A. E.
    Mostafa, M. H.
    Al-Sourori, A. A.
    JOURNAL OF OSSEOINTEGRATION, 2018, 10 (04) : 136 - 141
  • [26] A longitudinal clinical assessment of spark erosion technology in implant-retained overdenture prostheses: A preliminary report
    Toljanic, JA
    Antoniou, D
    Clark, RS
    Graham, L
    JOURNAL OF PROSTHETIC DENTISTRY, 1997, 78 (05): : 490 - 495
  • [27] Effect of an implant-retained complete overdenture on the hearing ability of edentulous patients: A clinical pilot study
    Shreedhar, Sindhuja
    Raza, Fathima Banu
    Vaidyanathan, Anand Kumar
    Veeravalli, Padmanabhan Thallam
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (04): : 628 - 635
  • [28] Comparison of Ball and Telescopic Crown Attachments in Implant-Retained Mandibular Overdentures: A 5-year Prospective Study
    Krennmair, Gerald
    Seemann, Rudolf
    Weinlaender, Michael
    Piehslinger, Eva
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (03) : 598 - 606
  • [29] Investigation of Clinical and Laboratory Wear in Locator-Supported, Implant-Retained Overdentures
    Hahnel, Sebastian
    Alamanos, Christos
    Schneider-Feyrer, Sibylle
    Stoeckle, Matthias
    Rosentritt, Martin
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (04) : 334 - 337
  • [30] In vitro study of a mandibular implant overdenture retained with ball, magnet, or bar attachments: Comparison of load transfer and denture stability
    Tokuhisa, M
    Matsushita, Y
    Koyano, K
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2003, 16 (02) : 128 - 134