WEAR OF CERAMIC AND TITANIUM BALL ATTACHMENTS IN SUBJECTS WITH AN IMPLANT-RETAINED OVERDENTURE: A CONTROLLED CLINICAL TRIAL

被引:1
|
作者
Buettel, Adrian E. [1 ]
Luethy, Heinz [2 ]
Sendi, Pedram [1 ]
Marinello, Carlo P. [1 ]
机构
[1] Univ Basel, Sch Dent, Clin Reconstruct Dent & Temporomandibular Disorde, CH-4056 Basel, Switzerland
[2] Univ Basel, Sch Dent, Inst Mat Sci, CH-4056 Basel, Switzerland
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2012年 / 107卷 / 02期
关键词
ELECTROPLATED GOLD COPINGS; MANDIBULAR OVERDENTURES; PATIENT SATISFACTION; TELESCOPIC RETAINER; EDENTULOUS PATIENTS; REMOVABLE DENTURES;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Loss of retention of implant-retained overdentures due to wear of the patrix or matrix of the attachment system is a common clinical problem. Purpose. The purpose of this controlled clinical trial was to compare the wear of ceramic and titanium ball attachments and their corresponding gold matrices after 1 year of clinical function in subjects with implant-retained mandibular overdentures. Material and methods. Forty subjects who had been treated with a 2-implant-retained overdenture received either 2 ruby ball attachments (20 subjects) or 2 titanium ball attachments (20 subjects). The diameter of the ball attachments and the thickness of the matrix were measured optically before insertion and after 1 year of clinical function. Differences among groups were then compared with the Wilcoxon rank sum test (alpha=.05). To estimate any correlation between clinical parameters and wear, the Spearman rank test was used. Results. There was no significant difference (P=.73) in the median wear of ball attachments for the titanium group (5.3 mu m; median 1.3 mu m) and for the ceramic group (1.3 mu m; median 1.3 mu m). In the ceramic group, a fracture rate of 30% was observed. The mean wear of the matrices in the titanium group was 3.1 mu m (median 6.8 mu m) and in the ceramic group 2.1 mu m (median 3.4 mu m), P=.01. No correlation was found between ball attachment wear and matrix insert wear (Spearman rank test). Wear of matrices was weakly correlated with an increase in divergence between implant axes in the sagittal plane (P=-.28 and P=.021). Ball attachment wear was associated with an increase in divergence between matrix axes in the sagittal plane (P=-.34 and P=.047). Conclusions. Matrices on ceramic ball attachments showed less wear than those placed on titanium ball attachments. However, the use of ruby ball attachments cannot be recommended because of a high fracture rate. (J Prosthet Dent 2012;107:109-113)
引用
收藏
页码:109 / 113
页数:5
相关论文
共 50 条
  • [1] Direct procedure for connecting a mandibular implant-retained overdenture with ball attachments
    Taddei, C
    Metz, M
    Waltman, E
    Etienne, O
    JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (04): : 403 - 404
  • [2] Implant-retained prostheses: ball vs. conus attachments - A randomized controlled clinical trial
    Cepa, Sandy
    Koller, Beatrice
    Spies, Benedikt Christopher
    Stampf, Susanne
    Kohal, Ralf-Joachim
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (02) : 177 - 185
  • [3] Mandibular implant-retained overdenture: A clinical trial of two anchorage systems
    Menicucci, G
    Lorenzetti, M
    Pera, P
    Preti, G
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1998, 13 (06) : 851 - 856
  • [4] IMPLANT-RETAINED OVERDENTURE AND O-RING ATTACHMENTS - CASE REPORT
    Bulegon, Andressa
    Rinaldi, Isadora
    Miyagaki, Daniela Cristina
    Sandini Linden, Maria Salete
    de Carli, Joao Paulo
    BIOSCIENCE JOURNAL, 2018, 34 (06): : 1796 - 1804
  • [5] Wear Assessment of Novel PEEK Telescopic Attachment for Implant-Retained Mandibular Overdenture: A Clinical Trial Study
    Quassem, Mohamed A.
    Badr, Wesam E.
    Mansour, Mamdouh M.
    Mahross, Hamada Z.
    OPEN DENTISTRY JOURNAL, 2024, 18
  • [6] A controlled clinical trial of implant-retained mandibular overdentures: Clinical aspects
    Boerrigter, EM
    VanOort, RP
    Raghoebar, GM
    Stegenga, B
    Schoen, PJ
    Boering, G
    JOURNAL OF ORAL REHABILITATION, 1997, 24 (03): : 182 - 190
  • [7] Influence of minimally invasive implant-retained overdenture on patients' quality of life: a randomized clinical trial
    Jofre, Jorge
    Castiglioni, Ximena
    Asenjo Lobos, Claudia
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (10) : 1173 - 1177
  • [8] Mandibular Denture Base Deformation with Locator and Ball Attachments of Implant-Retained Overdentures
    ELsyad, Moustafa Abdou
    Errabti, Hatem Mokhtar
    Mustafa, Aisha Zakaria
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (08): : 656 - 664
  • [10] Retention and wear of implant-supported ball and socket overdenture attachments.
    Munshi, IE
    Essop, ARM
    Slabbert, JCG
    Chandler, HD
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 1204 - 1204