Sensitive detection of colchicine at a glassy carbon electrode modified with magnetic ionic liquid/CuO nanoparticles/carbon nanofibers in pharmaceutical and plasma samples

被引:11
|
作者
Afzali, Moslem [1 ,2 ]
Mostafavi, Ali [1 ]
Shamspur, Tayebeh [1 ]
机构
[1] Shahid Bahonar Univ Kerman, Dept Chem, Kerman, Iran
[2] Shahid Bahonar Univ Kerman, Young Researchers Soc, Kerman, Iran
关键词
Colchicine; 1-butyl-3-methylimidazolium tetrachloroferrate; Copper oxide nanoparticles; Carbon nanofibers; Differential pulse voltammetry; CORE-SHELL NANOPARTICLES; GRAPHENE OXIDE; ELECTROCHEMICAL DETERMINATION; HPLC-UV; SENSOR; NANOCOMPOSITE; QUANTIFICATION; MICROEXTRACTION; DERIVATIVES; BEHAVIOR;
D O I
10.1007/s13738-020-01894-2
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In the present study, we utilized a novel electrochemical sensor for the determination of colchicine in 0.1 M phosphate buffer solution (pH 4.0) using differential pulse voltammetry. 1-butyl-3-methylimidazolium tetrachloroferrate ([Bmim]FeCl4) was synthesized, investigated by FT-IR, Raman and UV-Vis spectrometer and applied as magnetic ionic liquid in electrode modification. The other modifier was copper oxide nanoparticles/carbon nanofiber composite (CuO/CNF) provided by electrospinning and evaluated by scanning electron microscopy, X-ray diffraction and Fourier transform infrared spectroscopy (FT-IR). Several electro-analytical parameters such as the electrochemical behavior of the modified electrode, scan rate, type and supporting electrolyte pH were studied for the determination of colchicine. Under the optimized experimental conditions, oxidative peak current increased linearly by increasing colchicine concentration in the range of 1.0 to 100.0 nM and detection limit was obtained 0.25 nM. The relative standard deviation for six replicate analyses of 20.0 nM and 58.0 nM colchicine solution was obtained to be +/- 3.17% and +/- 2.08%, respectively. The proposed electrochemical sensor was successfully applied for colchicine quantification in colchicine tablet and health human plasma with satisfying results.
引用
收藏
页码:1753 / 1764
页数:12
相关论文
共 50 条
  • [31] Modified glassy carbon electrode with multiwall carbon nanotubes as a voltammetric sensor for determination of noscapine in biological and pharmaceutical samples
    Rezaei, Behzad
    Zare, S. Zohreh Mirahmadi
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 134 (01): : 292 - 299
  • [32] Modified glassy carbon electrode with multiwall carbon nanotubes as a voltammetric sensor for determination of leucine in biological and pharmaceutical samples
    Rezaei, B.
    Zare, Z. Mirahmadi
    ANALYTICAL LETTERS, 2008, 41 (12) : 2267 - 2286
  • [33] Ionic liquid-multi walled carbon nanotubes-L-lysine modified glassy carbon electrode for detection of prednisolone
    Kilele, Joan Chepkoech
    Chokkareddy, Rajasekhar
    Redhi, Gan G.
    JOURNAL OF MOLECULAR LIQUIDS, 2022, 363
  • [34] Highly sensitive electrochemical detection of adenine on a graphene-modified carbon ionic liquid electrode
    Wei Sun
    Jun Liu
    Xiaomei Ju
    Le Zhang
    Xiaowei Qi
    Ni Hui
    Ionics, 2013, 19 : 657 - 663
  • [35] Electrodeposited Graphene and Gold Nanoparticle Modified Carbon Ionic Liquid Electrode for Sensitive Detection of Rutin
    Sun Wei
    Wang Dan
    Zhang Yuan-Yuan
    Ju Xiao-Mei
    Yang Hai-Xu
    Chen Yi-Xin
    Sun Zhen-Fan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (05) : 709 - 713
  • [36] Highly sensitive electrochemical detection of adenine on a graphene-modified carbon ionic liquid electrode
    Sun, Wei
    Liu, Jun
    Ju, Xiaomei
    Zhang, Le
    Qi, Xiaowei
    Hui, Ni
    IONICS, 2013, 19 (04) : 657 - 663
  • [37] Determination of zearalenone with a glassy carbon electrode modified with nanocomposite consisting of palladium nanoparticles and a conductive polymeric ionic liquid
    Afzali, Daryoush
    Fathirad, Fariba
    MICROCHIMICA ACTA, 2016, 183 (09) : 2633 - 2638
  • [38] Direct proteins electrochemistry based on ionic liquid mediated carbon nanotube modified glassy carbon electrode
    Zhao, Q
    Zhan, DP
    Ma, HY
    Zhang, MQ
    Zhao, YF
    Jing, P
    Zhu, ZW
    Wan, XH
    Shao, YH
    Zhuang, QK
    FRONTIERS IN BIOSCIENCE, 2005, 10 : 326 - 334
  • [39] Determination of zearalenone with a glassy carbon electrode modified with nanocomposite consisting of palladium nanoparticles and a conductive polymeric ionic liquid
    Daryoush Afzali
    Fariba Fathirad
    Microchimica Acta, 2016, 183 : 2633 - 2638
  • [40] Application of a glassy carbon electrode modified with carbon black nanoparticles for highly sensitive voltammetric determination of quetiapine
    Lawrywianiec, M.
    Smajdor, J.
    Paczosa-Bator, B.
    Piech, R.
    ANALYTICAL METHODS, 2017, 9 (47) : 6662 - 6668