Sensitive detection of colchicine at a glassy carbon electrode modified with magnetic ionic liquid/CuO nanoparticles/carbon nanofibers in pharmaceutical and plasma samples

被引:11
|
作者
Afzali, Moslem [1 ,2 ]
Mostafavi, Ali [1 ]
Shamspur, Tayebeh [1 ]
机构
[1] Shahid Bahonar Univ Kerman, Dept Chem, Kerman, Iran
[2] Shahid Bahonar Univ Kerman, Young Researchers Soc, Kerman, Iran
关键词
Colchicine; 1-butyl-3-methylimidazolium tetrachloroferrate; Copper oxide nanoparticles; Carbon nanofibers; Differential pulse voltammetry; CORE-SHELL NANOPARTICLES; GRAPHENE OXIDE; ELECTROCHEMICAL DETERMINATION; HPLC-UV; SENSOR; NANOCOMPOSITE; QUANTIFICATION; MICROEXTRACTION; DERIVATIVES; BEHAVIOR;
D O I
10.1007/s13738-020-01894-2
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In the present study, we utilized a novel electrochemical sensor for the determination of colchicine in 0.1 M phosphate buffer solution (pH 4.0) using differential pulse voltammetry. 1-butyl-3-methylimidazolium tetrachloroferrate ([Bmim]FeCl4) was synthesized, investigated by FT-IR, Raman and UV-Vis spectrometer and applied as magnetic ionic liquid in electrode modification. The other modifier was copper oxide nanoparticles/carbon nanofiber composite (CuO/CNF) provided by electrospinning and evaluated by scanning electron microscopy, X-ray diffraction and Fourier transform infrared spectroscopy (FT-IR). Several electro-analytical parameters such as the electrochemical behavior of the modified electrode, scan rate, type and supporting electrolyte pH were studied for the determination of colchicine. Under the optimized experimental conditions, oxidative peak current increased linearly by increasing colchicine concentration in the range of 1.0 to 100.0 nM and detection limit was obtained 0.25 nM. The relative standard deviation for six replicate analyses of 20.0 nM and 58.0 nM colchicine solution was obtained to be +/- 3.17% and +/- 2.08%, respectively. The proposed electrochemical sensor was successfully applied for colchicine quantification in colchicine tablet and health human plasma with satisfying results.
引用
收藏
页码:1753 / 1764
页数:12
相关论文
共 50 条
  • [21] Highly sensitive determination of promazine in pharmaceutical and biological samples using a ZnO nanoparticle-modified ionic liquid carbon paste electrode
    Arabali, Vahid
    Ebrahimi, Mahmoud
    Karimi-Maleh, Hassan
    CHINESE CHEMICAL LETTERS, 2016, 27 (05) : 779 - 782
  • [22] Highly sensitive determination of promazine in pharmaceutical and biological samples using a ZnO nanoparticle-modified ionic liquid carbon paste electrode
    Vahid Arabali
    Mahmoud Ebrahimi
    Hassan Karimi-Maleh
    Chinese Chemical Letters, 2016, 27 (05) : 779 - 782
  • [23] Highly sensitive electrocatalytic detection of nitrite based on SiC nanoparticles/amine terminated ionic liquid modified glassy carbon electrode integrated with flow injection analysis
    Salimi, Abdollah
    Kurd, Masoumeh
    Teymourian, Hazhir
    Hallaj, Rahman
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 205 : 136 - 142
  • [24] A New Approach on Sensitive Assay of Adefovir in Pharmaceutical and Biological Fluid Samples Using Polypyrrole Modified Glassy Carbon Electrode
    Zaabal, Moufida
    Bakirhan, Nurgul K.
    Doulache, Merzak
    Kaddour, Samia
    Saidat, Boubakeur
    Ozkan, Sibel A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 323 (323):
  • [25] Sensitive amperometric detection of omeprazole and pantoperazole at electrodeposited nickel oxide nanoparticles modified glassy carbon electrode
    Abdollah Salimi
    Zahra Enferadi
    Abdollah Noorbakhash
    Kayomars Rashidi
    Journal of Solid State Electrochemistry, 2012, 16 : 1369 - 1375
  • [26] Electrochemical sensor based on a glassy carbon electrode modified with a 3D carbon nanoporous composite for the detection of paracetamol in pharmaceutical samples
    Rodriguez, J. A. Cabas
    Bonetto, A.
    Alaniz, R. D.
    Zon, M. A.
    Pierini, G. D.
    Rodriguez, R. Coneo
    Planes, G.
    Fernandez, H.
    Arevalo, F. J.
    Granero, A. M.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2024, 973
  • [27] Sensitive amperometric detection of omeprazole and pantoperazole at electrodeposited nickel oxide nanoparticles modified glassy carbon electrode
    Salimi, Abdollah
    Enferadi, Zahra
    Noorbakhash, Abdollah
    Rashidi, Kayomars
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (04) : 1369 - 1375
  • [28] Highly sensitive deoxynivalenol immunosensor based on a glassy carbon electrode modified with a fullerene/ferrocene/ionic liquid composite
    Wei Zhilei
    Sun Xiulan
    Li Zaijun
    Fang Yinjun
    Ren Guoxiao
    Huang Yaru
    Liu Junkang
    MICROCHIMICA ACTA, 2011, 172 (3-4) : 365 - 371
  • [29] Sensitive electrochemical detection of enzymatically generated thiocholine at carbon nanotube modified glassy carbon electrode
    Liu, GD
    Riechers, SL
    Mellen, MC
    Lin, YH
    ELECTROCHEMISTRY COMMUNICATIONS, 2005, 7 (11) : 1163 - 1169
  • [30] Highly sensitive deoxynivalenol immunosensor based on a glassy carbon electrode modified with a fullerene/ferrocene/ionic liquid composite
    Wei Zhilei
    Sun Xiulan
    Li Zaijun
    Fang Yinjun
    Ren Guoxiao
    Huang Yaru
    Liu Junkang
    Microchimica Acta, 2011, 172 : 365 - 371