A model-constrained Monte Carlo method for blind arterial input function estimation in dynamic contrast-enhanced MRI: I. Simulations

被引:36
|
作者
Schabel, Matthias C. [1 ]
Fluckiger, Jacob U. [1 ]
DiBella, Edward V. R. [1 ]
机构
[1] Univ Utah, Hlth Sci Ctr, Dept Radiol, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84108 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2010年 / 55卷 / 16期
关键词
REFERENCE TISSUE METHOD; REFERENCE REGION MODEL; KINETIC-PARAMETERS; RHEUMATOID-ARTHRITIS; PERFUSION MRI; DCE-MRI; GRADIENT-ECHO; VASCULAR-PERMEABILITY; BLOOD-VOLUME; QUANTIFICATION;
D O I
10.1088/0031-9155/55/16/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Widespread adoption of quantitative pharmacokinetic modeling methods in conjunction with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has led to increased recognition of the importance of obtaining accurate patient-specific arterial input function (AIF) measurements. Ideally, DCE-MRI studies use an AIF directly measured in an artery local to the tissue of interest, along with measured tissue concentration curves, to quantitatively determine pharmacokinetic parameters. However, the numerous technical and practical difficulties associated with AIF measurement have made the use of population-averaged AIF data a popular, if sub-optimal, alternative to AIF measurement. In this work, we present and characterize a new algorithm for determining the AIF solely from the measured tissue concentration curves. This Monte Carlo blind estimation (MCBE) algorithm estimates the AIF from the subsets of D concentration-time curves drawn from a larger pool of M candidate curves via nonlinear optimization, doing so for multiple (Q) subsets and statistically averaging these repeated estimates. The MCBE algorithm can be viewed as a generalization of previously published methods that employ clustering of concentration-time curves and only estimate the AIF once. Extensive computer simulations were performed over physiologically and experimentally realistic ranges of imaging and tissue parameters, and the impact of choosing different values of D and Q was investigated. We found the algorithm to be robust, computationally efficient and capable of accurately estimating the AIF even for relatively high noise levels, long sampling intervals and low diversity of tissue curves. With the incorporation of bootstrapping initialization, we further demonstrated the ability to blindly estimate AIFs that deviate substantially in shape from the population-averaged initial guess. Pharmacokinetic parameter estimates for K-trans, k(ep), v(p) and v(e) all showed relative biases and uncertainties of less than 10% for measurements having a temporal sampling rate of 4 s and a concentration measurement noise level of sigma = 0.04 mM. A companion paper discusses the application of the MCBE algorithm to DCE-MRI data acquired in eight patients with malignant brain tumors.
引用
收藏
页码:4783 / 4806
页数:24
相关论文
共 50 条
  • [1] A model-constrained Monte Carlo method for blind arterial input function estimation in dynamic contrast-enhanced MRI: II. In vivo results
    Schabel, Matthias C.
    DiBella, Edward V. R.
    Jensen, Randy L.
    Salzman, Karen L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (16): : 4807 - 4823
  • [2] Blind estimation of the arterial input function in dynamic contrast-enhanced MRI using purity maximization
    Lin, Yu-Chun
    Chan, Tsung-Han
    Chi, Chong-Yung
    Ng, Shu-Hang
    Liu, Hao-Li
    Wei, Kuo-Chen
    Wai, Yau-Yau
    Wang, Chun-Chieh
    Wang, Jiun-Jie
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (05) : 1439 - 1449
  • [3] Blind Multi-Channel Estimation of Arterial Input Function in Dynamic Contrast-Enhanced MRI
    Jirik, R.
    Bartos, M.
    Standara, M.
    Taxt, T.
    ANALYSIS OF BIOMEDICAL SIGNALS AND IMAGES, 2010, : 373 - 377
  • [4] Correcting saturation effects of the arterial input function in dynamic susceptibility contrast-enhanced MRI -: a Monte Carlo simulation
    Brunecker, Peter
    Villringer, Arno
    Schultze, Joerg
    Nolte, Christian H.
    Jungehuelsing, Gerhard Jan
    Endres, Matthias
    Steinbrink, Jens
    MAGNETIC RESONANCE IMAGING, 2007, 25 (09) : 1300 - 1311
  • [5] Operator dependency of arterial input function in dynamic contrast-enhanced MRI
    Kleppesto, Magne
    Bjornerud, Atle
    Groote, Inge Rasmus
    Kim, Minjae
    Vardal, Jonas
    Larsson, Christopher
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2022, 35 (01) : 105 - 112
  • [6] Correction of arterial input function in dynamic contrast-enhanced MRI of the liver
    Wang, Hesheng
    Cao, Yue
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (02) : 411 - 421
  • [7] Operator dependency of arterial input function in dynamic contrast-enhanced MRI
    Magne Kleppestø
    Atle Bjørnerud
    Inge Rasmus Groote
    Minjae Kim
    Jonas Vardal
    Christopher Larsson
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2022, 35 : 105 - 112
  • [8] Arterial input function estimation compensating for inflow and partial voluming in dynamic contrast-enhanced MRI
    Tseng, Chih-Hsien
    Nagtegaal, Martijn A.
    van Osch, Matthias J. P.
    Jaspers, Jaap
    Romero, Alejandra Mendez
    Wielopolski, Piotr
    Smits, Marion
    Vos, Frans M.
    NMR IN BIOMEDICINE, 2024, 37 (12)
  • [9] Selection of Fitting Model and Arterial Input Function for Repeatability in Dynamic Contrast-Enhanced Prostate MRI
    Peled, Sharon
    Vangel, Mark
    Kikinis, Ron
    Tempany, Clare M.
    Fennessy, Fiona M.
    Fedorov, Andrey
    ACADEMIC RADIOLOGY, 2019, 26 (09) : E241 - E251
  • [10] Arterial input function for quantitative dynamic contrast-enhanced MRI to diagnose prostate cancer
    Ziayee, Farid
    Mueller-Lutz, Anja
    Gross, Janina
    Ullrich, Tim
    Quentin, Michael
    Arsov, Christian
    Antoch, Gerald
    Wittsack, Hans-Joerg
    Schimmoeller, Lars
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2022, 28 (02) : 108 - 114