Arterial input function estimation compensating for inflow and partial voluming in dynamic contrast-enhanced MRI

被引:0
|
作者
Tseng, Chih-Hsien [1 ,2 ,3 ,4 ,5 ,6 ]
Nagtegaal, Martijn A. [1 ,7 ]
van Osch, Matthias J. P. [2 ,3 ,4 ,5 ,6 ,7 ]
Jaspers, Jaap [3 ,4 ,5 ,6 ,8 ]
Romero, Alejandra Mendez [3 ,4 ,5 ,6 ,8 ]
Wielopolski, Piotr [9 ]
Smits, Marion [2 ,9 ,10 ]
Vos, Frans M. [1 ,2 ,3 ,4 ,5 ,6 ,9 ]
机构
[1] Delft Univ Technol, Dept Imaging Phys, Lorentzweg 1, NL-2628 CJ Delft, Netherlands
[2] Med Delta, Delft, Netherlands
[3] Erasmus MC, HollandPTC Consortium, Rotterdam, Netherlands
[4] Holland Proton Therapy Ctr, Delft, Netherlands
[5] Leiden Univ, Med Ctr, Leiden, Netherlands
[6] Delft Univ Technol, Delft, Netherlands
[7] Leiden Univ, CJ Gorter MRI Ctr, Med Ctr, Dept Radiol, Leiden, Netherlands
[8] Univ Med Ctr Rotterdam, Erasmus MC Canc Inst, Dept Radiotherapy, Rotterdam, Netherlands
[9] Univ Med Ctr Rotterdam, Dept Radiol & Nucl Med, Erasmus MC, Rotterdam, Netherlands
[10] Univ Med Ctr Rotterdam, Erasmus MC Canc Inst, Brain Tumour Ctr, Rotterdam, Netherlands
关键词
arterial input function; DCE MRI; inflow effect; partial volume effect; KINETIC-PARAMETERS; PERFUSION MRI; BLOOD; QUANTIFICATION; VARIABILITY; ACQUISITION; TISSUE; YIELD;
D O I
10.1002/nbm.5225
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Both inflow and the partial volume effect (PVE) are sources of error when measuring the arterial input function (AIF) in dynamic contrast-enhanced (DCE) MRI. This is relevant, as errors in the AIF can propagate into pharmacokinetic parameter estimations from the DCE data. A method was introduced for flow correction by estimating and compensating the number of the perceived pulse of spins during inflow. We hypothesized that the PVE has an impact on concentration-time curves similar to inflow. Therefore, we aimed to study the efficiency of this method to compensate for both effects simultaneously. We first simulated an AIF with different levels of inflow and PVE contamination. The peak, full width at half-maximum (FWHM), and area under curve (AUC) of the reconstructed AIFs were compared with the true (simulated) AIF. In clinical data, the PVE was included in AIFs artificially by averaging the signal in voxels surrounding a manually selected point in an artery. Subsequently, the artificial partial volume AIFs were corrected and compared with the AIF from the selected point. Additionally, corrected AIFs from the internal carotid artery (ICA), the middle cerebral artery (MCA), and the venous output function (VOF) estimated from the superior sagittal sinus (SSS) were compared. As such, we aimed to investigate the effectiveness of the correction method with different levels of inflow and PVE in clinical data. The simulation data demonstrated that the corrected AIFs had only marginal bias in peak value, FWHM, and AUC. Also, the algorithm yielded highly correlated reconstructed curves over increasingly larger neighbourhoods surrounding selected arterial points in clinical data. Furthermore, AIFs measured from the ICA and MCA produced similar peak height and FWHM, whereas a significantly larger peak and lower FWHM was found compared with the VOF. Our findings indicate that the proposed method has high potential to compensate for PVE and inflow simultaneously. The corrected AIFs could thereby provide a stable input source for DCE analysis. The partial volume effect (PVE) exerts a relatively equivalent impact as the inflow effect does on arterial input function (AIF) measurement in DCE MRI. We propose a compensatory approach, addressing PVE and inflow correction simultaneously by estimating the perceived pulse number of protons implicitly. This method adeptly reconstructs the AIF with minimal bias, as demonstrated in simulations and clinical datasets. While the venous output function (VOF) from the superior sagittal sinus is a contemplated alternative in clinic, our findings reveal significant dispersion-induced differences between the VOF and AIF in DCE MRI. image
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Operator dependency of arterial input function in dynamic contrast-enhanced MRI
    Kleppesto, Magne
    Bjornerud, Atle
    Groote, Inge Rasmus
    Kim, Minjae
    Vardal, Jonas
    Larsson, Christopher
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2022, 35 (01) : 105 - 112
  • [2] Correction of arterial input function in dynamic contrast-enhanced MRI of the liver
    Wang, Hesheng
    Cao, Yue
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (02) : 411 - 421
  • [3] Operator dependency of arterial input function in dynamic contrast-enhanced MRI
    Magne Kleppestø
    Atle Bjørnerud
    Inge Rasmus Groote
    Minjae Kim
    Jonas Vardal
    Christopher Larsson
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2022, 35 : 105 - 112
  • [4] Blind Multi-Channel Estimation of Arterial Input Function in Dynamic Contrast-Enhanced MRI
    Jirik, R.
    Bartos, M.
    Standara, M.
    Taxt, T.
    ANALYSIS OF BIOMEDICAL SIGNALS AND IMAGES, 2010, : 373 - 377
  • [5] Blind estimation of the arterial input function in dynamic contrast-enhanced MRI using purity maximization
    Lin, Yu-Chun
    Chan, Tsung-Han
    Chi, Chong-Yung
    Ng, Shu-Hang
    Liu, Hao-Li
    Wei, Kuo-Chen
    Wai, Yau-Yau
    Wang, Chun-Chieh
    Wang, Jiun-Jie
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (05) : 1439 - 1449
  • [6] Effects of Inflow and Radiofrequency Spoiling on the Arterial Input Function in Dynamic Contrast-Enhanced MRI: A Combined Phantom and Simulation Study
    Garpebring, Anders
    Wirestam, Ronnie
    Ostlund, Nils
    Karlsson, Mikael
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (06) : 1670 - 1679
  • [7] Arterial input function for quantitative dynamic contrast-enhanced MRI to diagnose prostate cancer
    Ziayee, Farid
    Mueller-Lutz, Anja
    Gross, Janina
    Ullrich, Tim
    Quentin, Michael
    Arsov, Christian
    Antoch, Gerald
    Wittsack, Hans-Joerg
    Schimmoeller, Lars
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2022, 28 (02) : 108 - 114
  • [8] Dynamic Contrast-Enhanced MRI in Mice at High Field: Estimation of the Arterial Input Function Can be Achieved by Phase Imaging
    Fruytier, A. -C.
    Magat, J.
    Colliez, F.
    Jordan, B.
    Cron, G.
    Gallez, B.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (02) : 544 - 550
  • [9] Selection of Fitting Model and Arterial Input Function for Repeatability in Dynamic Contrast-Enhanced Prostate MRI
    Peled, Sharon
    Vangel, Mark
    Kikinis, Ron
    Tempany, Clare M.
    Fennessy, Fiona M.
    Fedorov, Andrey
    ACADEMIC RADIOLOGY, 2019, 26 (09) : E241 - E251
  • [10] Effects of arterial input function selection on kinetic parameters in brain dynamic contrast-enhanced MRI
    Keil, Vera C.
    Maedler, Burkhard
    Gieseke, Juergen
    Fimmers, Rolf
    Hattingen, Elke
    Schild, Hans H.
    Hadizadeh, Dariusch R.
    MAGNETIC RESONANCE IMAGING, 2017, 40 : 83 - 90