A model-constrained Monte Carlo method for blind arterial input function estimation in dynamic contrast-enhanced MRI: I. Simulations

被引:36
|
作者
Schabel, Matthias C. [1 ]
Fluckiger, Jacob U. [1 ]
DiBella, Edward V. R. [1 ]
机构
[1] Univ Utah, Hlth Sci Ctr, Dept Radiol, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84108 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2010年 / 55卷 / 16期
关键词
REFERENCE TISSUE METHOD; REFERENCE REGION MODEL; KINETIC-PARAMETERS; RHEUMATOID-ARTHRITIS; PERFUSION MRI; DCE-MRI; GRADIENT-ECHO; VASCULAR-PERMEABILITY; BLOOD-VOLUME; QUANTIFICATION;
D O I
10.1088/0031-9155/55/16/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Widespread adoption of quantitative pharmacokinetic modeling methods in conjunction with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has led to increased recognition of the importance of obtaining accurate patient-specific arterial input function (AIF) measurements. Ideally, DCE-MRI studies use an AIF directly measured in an artery local to the tissue of interest, along with measured tissue concentration curves, to quantitatively determine pharmacokinetic parameters. However, the numerous technical and practical difficulties associated with AIF measurement have made the use of population-averaged AIF data a popular, if sub-optimal, alternative to AIF measurement. In this work, we present and characterize a new algorithm for determining the AIF solely from the measured tissue concentration curves. This Monte Carlo blind estimation (MCBE) algorithm estimates the AIF from the subsets of D concentration-time curves drawn from a larger pool of M candidate curves via nonlinear optimization, doing so for multiple (Q) subsets and statistically averaging these repeated estimates. The MCBE algorithm can be viewed as a generalization of previously published methods that employ clustering of concentration-time curves and only estimate the AIF once. Extensive computer simulations were performed over physiologically and experimentally realistic ranges of imaging and tissue parameters, and the impact of choosing different values of D and Q was investigated. We found the algorithm to be robust, computationally efficient and capable of accurately estimating the AIF even for relatively high noise levels, long sampling intervals and low diversity of tissue curves. With the incorporation of bootstrapping initialization, we further demonstrated the ability to blindly estimate AIFs that deviate substantially in shape from the population-averaged initial guess. Pharmacokinetic parameter estimates for K-trans, k(ep), v(p) and v(e) all showed relative biases and uncertainties of less than 10% for measurements having a temporal sampling rate of 4 s and a concentration measurement noise level of sigma = 0.04 mM. A companion paper discusses the application of the MCBE algorithm to DCE-MRI data acquired in eight patients with malignant brain tumors.
引用
收藏
页码:4783 / 4806
页数:24
相关论文
共 50 条
  • [31] Effects of artery input function on dynamic contrast-enhanced MRI for determining grades of gliomas
    Jia, Lin
    Wu, Xia
    Wan, Qian
    Wan, Liwen
    Jia, Wenxiao
    Zhang, Na
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1119):
  • [32] Automatic Determination of Arterial Input Function for Dynamic Contrast Enhanced MRI in Tumor Assessment
    Chen, Jeremy
    Yao, Jianhua
    Thornasson, David
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2008, PT I, PROCEEDINGS, 2008, 5241 : 594 - 601
  • [33] Influence of Different Measurement Methods of Arterial Input Function on Quantitative Dynamic Contrast-Enhanced MRI Parameters in Head and Neck Cancer
    Dong, Wanxin
    Volk, Andreas
    Djaroum, Meriem
    Girot, Charly
    Balleyguier, Corinne
    Lebon, Vincent
    Garcia, Gabriel
    Ammari, Samy
    Temam, Stephane
    Gorphe, Philippe
    Wei, Lecong
    Pitre-Champagnat, Stephanie
    Lassau, Nathalie
    Bidault, Francois
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 58 (01) : 122 - 132
  • [34] Impact of the arterial input function on microvascularization parameter measurements using dynamic contrast-enhanced ultrasonography
    Gauthier, Marianne
    Pitre-Champagnat, Stephanie
    Tabarout, Farid
    Leguerney, Ingrid
    Polrot, Melanie
    Lassau, Nathalie
    WORLD JOURNAL OF RADIOLOGY, 2012, 4 (07): : 291 - 301
  • [35] Pharmacokinetic modeling of dynamic contrast-enhanced MRI using a reference region and input function tail
    Ahmed, Zaki
    Levesque, Ives R.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (01) : 286 - 298
  • [36] Use of Cardiac Output to Improve Measurement of Input Function in Quantitative Dynamic Contrast-Enhanced MRI
    Zhang, Jeff L.
    Rusinek, Henry
    Bokacheva, Louisa
    Chen, Qun
    Storey, Pippa
    Lee, Vivian S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (03) : 656 - 665
  • [37] Dynamic Contrast-Enhanced MRI in Mice at High Field: Estimation of the Arterial Input Function Can Be Achieved by Phase Imaging (vol 71, pg 544, 2014)
    Fruytier, Anne-Catherine
    Magat, Julie
    Jordan, Benedicte
    Cron, Greg
    Colliez, Florence
    Gallez, Bernard
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (02) : 602 - 602
  • [38] Improving the Arterial Input Function in Dynamic Contrast Enhanced MRI by Fitting the Signal in the Complex Plane
    Simonis, Frank F. J.
    Sbrizzi, Alessandro
    Beld, Ellis
    Lagendijk, Jan J. W.
    van den Berg, Cornelis A. T.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (04) : 1236 - 1245
  • [39] Quantitative Estimation of Renal Function with Dynamic Contrast-Enhanced MRI Using a Modified Two-Compartment Model
    Chen, Bin
    Zhang, Yudong
    Song, Xiaojian
    Wang, Xiaoying
    Zhang, Jue
    Fang, Jing
    PLOS ONE, 2014, 9 (08):
  • [40] A simulation study comparing nine mathematical models of arterial input function for dynamic contrast enhanced MRI to the Parker model
    Dianning He
    Lisheng Xu
    Wei Qian
    James Clarke
    Xiaobing Fan
    Australasian Physical & Engineering Sciences in Medicine, 2018, 41 : 507 - 518