Testing the X-IFU calibration requirements: an example for quantum efficiency and energy resolution

被引:2
|
作者
Cucchetti, Edoardo [1 ]
Pajot, Francois [1 ]
Pointecouteau, Etienne [1 ]
Peille, Philippe [2 ]
Betancourt-Martinez, Gabriele [1 ]
Smith, Stephen J. [3 ,4 ,5 ,6 ]
Barbera, Marco [7 ,8 ]
Eckart, Megan E. [3 ,9 ]
Bandler, Simon R. [3 ]
Kilbourne, Caroline A. [3 ]
Cappi, Massimo
Barret, Didier [1 ]
机构
[1] Univ Toulouse, IRAP, CNRS, CNES, 9 Ave Colonel Roche, F-31400 Toulouse, France
[2] CNES, 18 Ave Edouard Belin, F-31400 Toulouse, France
[3] NASA, Goddard Space Flight Ctr, 8800 Greenbelt Rd, Greenbelt, MD 20771 USA
[4] CRESST, Baltimore, MD 21250 USA
[5] Univ Maryland Baltimore Cty, Baltimore, MD 21250 USA
[6] Univ Maryland, College Pk, MD 20742 USA
[7] Univ Palermo, Dipartimento Fis & Chim, Via Archirafi 36, I-90123 Palermo, Italy
[8] Ist Nazl Astrofis, Osservatorio Astron Palermo, Piazza Parlamento 1, I-90134 Palermo, Italy
[9] INAF, IASF Bologna, Via Gobetti 101, I-40129 Bologna, Italy
关键词
Athena; X-IFU; X-rays; Calibration; Performance verification; INTEGRAL FIELD UNIT;
D O I
10.1117/12.2312188
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
With its array of 3840 Transition Edge Sensors (TESs) operated at 90 mK, the X-Ray Integral Field Unit (X-IFU) on board the ESA L2 mission Athena will provide spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) over the 0.2 to 12 keV bandpass. The in-flight performance of the X-IFU will be strongly affected by the calibration of the instrument. Uncertainties in the knowledge of the overall system, from the filter transmission to the energy scale, may introduce systematic errors in the data, which could potentially compromise science objectives - notably those involving line characterisation e.g. turbulence velocity measurements - if not properly accounted for. Defining and validating calibration requirements is therefore of paramount importance. In this paper, we put forward a simulation tool based on the most up-to-date configurations of the various subsystems (e.g. filters, detector absorbers) which allows us to estimate systematic errors related to uncertainties in the instrumental response. Notably, the effect of uncertainties in the energy resolution and of the instrumental quantum efficiency on X-IFU observations is assessed, by taking as a test case the measurements of the iron K complex in the hot gas surrounding clusters of galaxies. In-flight and ground calibration of the energy resolution and the quantum efficiency is also addressed. We demonstrate that provided an accurate calibration of the instrument, such effects should be low in both cases with respect to statistics during observations.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Efficiency calibration and surface mapping of an energy-dispersive detector with SOLEX: A compact tunable monochromatic X-ray source
    Menesguen, Y.
    Lepy, M. -C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 695 : 193 - 196
  • [32] Detective quantum efficiency of a double-layered detector for dual-energy x-ray imaging
    Shin, Hubeom
    Yoo, Seungjun
    Oh, Seokwon
    Lee, Junho
    Kyung, Ho
    JOURNAL OF INSTRUMENTATION, 2023, 18 (11)
  • [33] Efficiency of metabolizable energy utilization for maintenance and weight gain and metabolizable energy and total digestible nutrients requirements of F1 Limousin x Nellore bulls
    Veloso, CM
    Valadares, SD
    Júnior, AG
    da Silva, FF
    Paulino, MF
    Valadares, RFD
    Cecon, PR
    Paulino, PVR
    REVISTA BRASILEIRA DE ZOOTECNIA-BRAZILIAN JOURNAL OF ANIMAL SCIENCE, 2002, 31 (03): : 1286 - 1293
  • [34] Energy resolution measurements of LaBr3:Ce scintillating crystals with an ultra-high quantum efficiency photomultiplier tube
    Pani, R.
    Cinti, M. N.
    Scafe, R.
    Pellegrini, R.
    Vittorini, F.
    Bennati, P.
    Ridolfi, S.
    Lo Meo, S.
    Mattioli, M.
    Baldazzi, G.
    Pisacane, F.
    Navarria, F.
    Moschini, G.
    Boccaccio, P.
    Cencelli, V. Orsolini
    Sacco, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 610 (01): : 41 - 44
  • [35] Calibration of intrinsic peak efficiency of a high-purity germanium detector for X-ray energy of 5.48-302.85 keV
    Ren, Kuan
    Zheng, Jianhua
    Xu, Tao
    Chen, Xilin
    Yi, Rongqing
    Diao, Lijun
    Wei, Kexin
    Song, Zifeng
    Du, Huabing
    Yao, Li
    Li, Chaoguang
    Zhang, Jiyan
    Yang, Jiamin
    Liu, Shenye
    Cao, Zhurong
    Huang, Tianxuan
    Dong, Jianjun
    Ding, Yongkun
    Jiang, Shaoen
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 903 : 262 - 266
  • [36] Organic Manganese Halides with Near-Unity Quantum Efficiency for High-Resolution and Flexible X-Ray Detection and Imaging
    Fan, Jiali
    Tong, Hua
    Zhou, Zhennan
    Lv, Yi
    Li, Haibo
    Liu, Wei
    Ouyang, Gangfeng
    SMALL, 2025, 21 (05)
  • [37] Detective quantum efficiency of a dual-energy photon-counting X-ray detector with charge sharing compensation
    Lee, Junho
    Yoo, Seungjun
    Oh, Seokwon
    Lim, Chang Hwy
    Park, Jong-Won
    Kim, Ho Kyung
    Journal of Instrumentation, 2025, 20 (01)
  • [38] Energy and resolution calibration of NaI(Tl) and LaBr3(Ce) scintillators and validation of an EGS5 Monte Carlo user code for efficiency calculations
    Casanovas, R.
    Morant, J. J.
    Salvado, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 675 : 78 - 83
  • [39] REDUCTION OF THE RESPONSIVITY OF THE ROSAT FOCAL PLANE X-RAY-DETECTOR (PSPC) TO ULTRAVIOLET-RADIATION AND ABSOLUTE CALIBRATION OF ITS UV-QUANTUM EFFICIENCY
    STEPHAN, KH
    BRIEL, U
    KAASE, H
    NEW DEVELOPMENTS AND APPLICATIONS IN OPTICAL RADIOMETRY, 1989, 92 : 173 - 186
  • [40] Calibration of boron concentration in CVD single crystal diamond combining ultralow energy secondary ions mass spectrometry and high resolution X-ray diffraction
    Guzmand de la Mata, B.
    Sanz-Hervas, A.
    Dowsett, M. G.
    Schwitters, M.
    Twitchen, D.
    DIAMOND AND RELATED MATERIALS, 2007, 16 (4-7) : 809 - 814