Efficiency calibration and surface mapping of an energy-dispersive detector with SOLEX: A compact tunable monochromatic X-ray source

被引:11
|
作者
Menesguen, Y. [1 ]
Lepy, M. -C. [1 ]
机构
[1] CEA, LIST, LNHB, F-91191 Gif Sur Yvette, France
关键词
Energy-dispersive spectrometer; Efficiency calibration; X-ray source; SI(LI) DETECTOR; RANGE; RADIATION;
D O I
10.1016/j.nima.2011.11.017
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This work presents the different measurement possibilities of the SOLEX facility for the characterization of an energy-dispersive detector. We first describe the SOLEX apparatus, its energy range and the internal proportional counter used for absolute flux measurement then we give an example of an energy-dispersive detector characterization. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:193 / 196
页数:4
相关论文
共 50 条
  • [1] SOLEX:: a tunable monochromatic X-ray source in the 1-20 keV energy range for metrology
    Bonnelle, C
    Jonnard, P
    André, JM
    Avila, A
    Laporte, D
    Ringuenet, H
    Lépy, MC
    Plagnard, J
    Ferreux, L
    Protas, JC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 516 (2-3): : 594 - 601
  • [2] Accurate efficiency calibration of a low-energy HPGe detector using a monochromatic x-ray source
    Plagnard, Johann
    Bobin, Christophe
    Lepy, Marie-Christine
    X-RAY SPECTROMETRY, 2007, 36 (03) : 191 - 198
  • [3] Energy-dispersive X-ray fluorescence analysis in geochemical mapping
    Civici, N
    VanGrieken, R
    X-RAY SPECTROMETRY, 1997, 26 (04) : 147 - 152
  • [4] Energy calibration and full-pattern refinement for strain analysis using energy-dispersive and monochromatic X-ray diffraction
    Liu, J
    Kim, K
    Golshan, M
    Laundy, D
    Korsunsky, AM
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2005, 38 : 661 - 667
  • [5] Energy-dispersive X-ray diffraction mapping on a benchtop X-ray fluorescence system
    Lane, David W.
    Nyombi, Antony
    Shackel, James
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2014, 47 : 488 - 494
  • [6] ENERGY-DISPERSIVE X-RAY SPECTROSCOPY
    HURLEY, JP
    DAGRAGNA.VL
    MATHIESEN, JM
    RESEARCH-DEVELOPMENT, 1970, 21 (12): : 14 - +
  • [7] The capabilities of an electrically cooled energy-dispersive x-ray detector for quantitative x-ray fluorescence analysis
    Kump, P
    Necemer, M
    Drinovec, J
    X-RAY SPECTROMETRY, 2004, 33 (02) : 107 - 111
  • [8] Energy-Dispersive X-ray Absorption Spectroscopy with an Inverse Compton Source
    Huang, Juanjuan
    Guenther, Benedikt
    Achterhold, Klaus
    Cui, Yi-tao
    Gleich, Bernhard
    Dierolf, Martin
    Pfeiffer, Franz
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [9] Energy-Dispersive X-ray Absorption Spectroscopy with an Inverse Compton Source
    Juanjuan Huang
    Benedikt Günther
    Klaus Achterhold
    Yi-tao Cui
    Bernhard Gleich
    Martin Dierolf
    Franz Pfeiffer
    Scientific Reports, 10
  • [10] Material specific X-ray imaging using an energy-dispersive pixel detector
    Egan, Christopher K.
    Wilson, Matthew D.
    Veale, Matthew C.
    Seller, Paul
    Jacques, Simon D. M.
    Cernik, Robert J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2014, 324 : 25 - 28